Exergy Based Performance Analysis of a Shower Cooling Tower

被引:8
|
作者
Qi, Xiaoni [1 ]
Liu, Yongqi [1 ]
Liu, Zhenyan [2 ]
机构
[1] Shandong Univ Technol, Coll Traff & Vehicle Engn, Zibo, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech & Power Engn, Shanghai, Peoples R China
关键词
shower cooling tower; exergy; heat and mass transfer;
D O I
10.5545/sv-jme.2012.315
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present study provides a descriptive mathematical model of energy and exergy for a shower cooling tower (SCT). The model is used to predict the variation in temperature and exergy along the tower length. The validity of the model for predicting variations in gas and liquid characteristics along the tower length was examined against some operating data measured in a cooling tower company. The results show that the exergy of water decreases as tower height increases. The distribution of the exergy loss is high at the bottom and gradually decreases moving up to the top of the tower. Moreover, 1.50 m/s air velocity results in less exergy destruction. With a decrease in the size of the water droplets, the fluids carrying energy have more opportunities for mass and energy transfers.
引用
收藏
页码:251 / 259
页数:9
相关论文
共 50 条
  • [1] Performance characteristics of a shower cooling tower
    Qi, Xiaoni
    Liu, Zhenyan
    Li, Dandan
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (01) : 193 - 203
  • [2] An exergy analysis on the performance of a counterflow wet cooling tower
    Muangnoi, Thirapong
    Asvapoositkul, Wanchai
    Wongwises, Somchai
    APPLIED THERMAL ENGINEERING, 2007, 27 (5-6) : 910 - 917
  • [3] Further investigation on the performance of a shower cooling tower
    Qi, Xiaoni
    Liu, Zhenyan
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (04) : 570 - 577
  • [4] Performance of the ''Shower'' cooling tower in different climates
    Givoni, B
    RENEWABLE ENERGY, 1997, 10 (2-3) : 173 - 178
  • [5] Experimental performance of the Shower Cooling Tower in Japan
    Yajima, S
    Givoni, B
    RENEWABLE ENERGY, 1997, 10 (2-3) : 179 - 183
  • [6] Performance of the Shower cooling tower in different climates
    Dept. of Architecture, UCLA, Los Angeles, CA, United States
    Renewable Energy, 10 (2-3 SPEC. ISS.): : 173 - 178
  • [7] Numerical Simulation and Experimental Analysis on the Performance of a Modified Shower Cooling Tower
    Anbazhaghan, N.
    Jayaraman, Jayaprabakar
    Appavu, Prabhu
    Joy, Nivin
    Harish, Amidela
    Poornachandu, Ch
    Gokulnath, R.
    3RD INTERNATIONAL CONFERENCE ON FRONTIERS IN AUTOMOBILE AND MECHANICAL ENGINEERING (FAME 2020), 2020, 2311
  • [8] Prediction of the performance of a shower cooling tower based on projection pursuit regression
    Qi, Xiaoni
    Liu, Zhenyan
    Li, Dandan
    APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) : 1031 - 1038
  • [9] Investigation of the effect of packing location on performance of closed wet cooling tower based on exergy analysis
    Qasim, S. M.
    Hayder, M. J.
    MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING IV, PTS 1-7, 2016, 145
  • [10] EXERGY ANALYSIS OFTHE CROSS CURRENT COOLING TOWER
    Rawabawale, Nandkumar
    Sapali, Shivalingappa
    JOURNAL OF THERMAL ENGINEERING, 2020, 6 (04): : 499 - 510