Aortic Aneurysms Delayed Complications of Coarctation of the Aorta Repair Using Dacron Patch Aortoplasty

被引:6
|
作者
Piciucchi, Sara [1 ,5 ]
Goodman, Lawrence R. [1 ]
Earing, Michael [2 ]
Nicolosi, Alfred [3 ]
Almassi, Hossein [3 ,4 ]
Tisol, William [3 ]
Shannon-Stone, Meg [3 ]
机构
[1] Med Coll Wisconsin, Dept Radiol, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Internal Med & Pediat, Div Adult Cardiovasc Med & Pediat Cardiol, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Div Cardiothorac Surg, Milwaukee, WI 53226 USA
[4] Zablocki Vet Adm Med Ctr, Div Cardiothorac Surg, Milwaukee, WI 53295 USA
[5] Univ Campus Biomed, Dept Radiodiagnost, Rome, Italy
关键词
aortic coarctation; aortic coarctation complications; pseudoaneurysm of aorta; aortobronchopleural fistula;
D O I
10.1097/RTI.0b013e3181824719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Coarctation of the aorta is a diaphragmlike ridge narrowing the lumen of the proximal descending aorta. Although surgical repair has proven to be a successful treatment of coarctation of the aorta, immediate and delayed postoperative complications are not rare. Of particular interest is the Occurrence of aneurysms after Dacron patch aortoplasty - often decades after Surgery. Delayed complication rates of up to 50% have been reported. We describe the clinical-radiologic presentations of 3 late complications of Dacron patch angioplasty: aortobronchopleural fistula, leaking pseudoaneurysm, and giant descending aortic aneurysm-all Successfully treated with bypass grafts. Because of the high incidence of delayed complications, lifelong Surveillance is necessary. The chest x-ray may be the first Clue to a delayed complication. Knowledge of radiologic finding,-, is helpful in the detection of complications before they become symptomatic. Transesophageal echocardiography, Computed tomography angiography, or magnetic resonance imaging with multiplanar reconstruction is diagnostic.
引用
收藏
页码:278 / 283
页数:6
相关论文
共 50 条
  • [1] RAPID PROGRESSION OF AORTIC-ANEURYSMS AFTER PATCH AORTOPLASTY REPAIR OF COARCTATION OF THE AORTA
    MENDELSOHN, AM
    CROWLEY, DC
    LINDAUER, A
    BEEKMAN, RH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 381 - 385
  • [2] Aortic aneurysm formation following coarctation repair by Dacron patch aortoplasty
    Walhout, R. J.
    Braam, R. L.
    Schepens, M. A.
    Mulder, B. J. M.
    Plokker, H. W. M.
    NETHERLANDS HEART JOURNAL, 2010, 18 (7-8): : 376 - 377
  • [3] Aortic aneurysm formation following coarctation repair by Dacron patch aortoplasty
    R. J. Walhout
    R. L. Braam
    M. A. Schepens
    B. J. M. Mulder
    H. W. M. Plokker
    Netherlands Heart Journal, 2010, 18 : 376 - 377
  • [4] AORTOPLASTY AND DACRON PATCH IN SURGICAL TREATMENT OF AORTIC COARCTATION
    SCIRE, F
    GIAIMO, G
    LEONE, A
    MIGLIORE, A
    MINERVA MEDICA, 1977, 68 (46) : 3201 - 3204
  • [5] Aortic aneurysm following Dacron patch repair for coarctation of the aorta
    Neumayer, U
    Schmidt, HK
    Fassbender, D
    Esdorn, H
    Minami, K
    Körfer, R
    Horstkotte, D
    INTERNIST, 2001, 42 (11): : 1513 - 1516
  • [6] COARCTATION OF THE AORTA - REPAIR WITH POLYTETRAFLUOROETHYLENE PATCH AORTOPLASTY
    BACKER, CL
    PAAPE, K
    ZALES, VR
    WEIGEL, TJ
    MAVROUDIS, C
    CIRCULATION, 1995, 92 (09) : 132 - 136
  • [7] COARCTATION OF THE AORTA REPAIR WITH POLYTETRAFLUOROETHYLENE PATCH AORTOPLASTY
    BACKER, CL
    PAAPE, K
    ZALES, VR
    WEIGEL, TJ
    MAVROUDIS, C
    CIRCULATION, 1994, 90 (04) : 203 - 203
  • [8] Aortic Aneurysms Remain a Significant Source of Morbidity and Mortality After Use of Dacron® Patch Aortoplasty to Repair Coarctation of the Aorta: Results from a Single Center
    Cramer, Jonathan W.
    Ginde, Salil
    Bartz, Peter J.
    Tweddell, James S.
    Litwin, S. Bert
    Earing, Michael G.
    PEDIATRIC CARDIOLOGY, 2013, 34 (02) : 296 - 301
  • [9] Aortic Aneurysms Remain a Significant Source of Morbidity and Mortality After Use of Dacron® Patch Aortoplasty to Repair Coarctation of the Aorta: Results from a Single Center
    Jonathan W. Cramer
    Salil Ginde
    Peter J. Bartz
    James S. Tweddell
    S. Bert Litwin
    Michael G. Earing
    Pediatric Cardiology, 2013, 34 : 296 - 301
  • [10] Aortopulmonary fistula after coarctation repair with Dacron patch aortoplasty
    Heikkinen, LO
    Järvinen, AA
    ANNALS OF THORACIC SURGERY, 2002, 73 (05): : 1634 - 1636