Preservation of the posterior cruciate ligament is not helpful in highly conforming mobile-bearing total knee arthroplasty: a randomized controlled study

被引:23
|
作者
Roh, Yoon Whan [1 ]
Jang, Jak [1 ]
Choi, Won Chul [1 ]
Lee, Joon Kyu [1 ]
Chun, Sae Hyung [1 ]
Lee, Sahnghoon [1 ]
Seong, Sang Cheol [1 ]
Lee, Myung Chul [1 ]
机构
[1] Seoul Natl Univ Hosp, Dept Orthoped Surg, Seoul 110744, South Korea
关键词
Total knee arthroplasty; Posterior cruciate ligament; Highly conforming polyethylene; Total knee arthroplasty kinematics; PATELLAR CLUNK SYNDROME; IN-VIVO KINEMATICS; TIBIAL COMPONENT; COMPLICATION; REPLACEMENTS; DISLOCATION; PROSTHESIS; FRACTURE; OUTCOMES; LAXITY;
D O I
10.1007/s00167-012-2265-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study is to investigate whether the preservation of the posterior cruciate ligament (PCL) can be helpful for improving kinematics and clinical outcome in highly conforming mobile-bearing total knee arthroplasty (TKA). Ninety osteoarthritic knees were randomly allocated to either the PCL-preserving group or the PCL-sacrificing group. Passive kinematics was recorded with a navigation system immediately after implantation. Three parameters (anterior/posterior translation, varus/valgus rotation, and internal/external rotation) were analysed from 0A degrees to 120A degrees flexion. The PCL-preserving group (42 knees) had more varus rotation over 90A degrees flexion (p < 0.05) and more anterior translation of the femur in all ranges of flexion (p < 0.05) than those in the PCL-sacrificing group (44 knees). There was no difference in the internal/external rotation (p > 0.05). The range of motion, functional scores, and radiographic results did not significantly differ between the two groups at the final follow-up. Three knees in the PCL-preserving group were revised: two presented with instability caused by traumatic attenuation of the PCL and one with subluxation of the insert due to a tight PCL. The preservation of the PCL was not helpful for improving kinematics and clinical outcome in highly conforming mobile-bearing TKA. II.
引用
收藏
页码:2850 / 2859
页数:10
相关论文
共 50 条
  • [1] Preservation of the posterior cruciate ligament is not helpful in highly conforming mobile-bearing total knee arthroplasty: a randomized controlled study
    Yoon Whan Roh
    Jak Jang
    Won Chul Choi
    Joon Kyu Lee
    Sae Hyung Chun
    Sahnghoon Lee
    Sang Cheol Seong
    Myung Chul Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2850 - 2859
  • [2] Balancing the posterior cruciate ligament during cruciate-retaining fixed and mobile-bearing total knee arthroplasty
    Scott, Richard D.
    Chmell, Michael J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04): : 605 - 608
  • [3] Sagittal Laxity After Posterior Cruciate Ligament-Retaining Mobile-Bearing Total Knee Arthroplasty
    Chouteau, Julien
    Lerat, Jean Luc
    Testa, Rodolph
    Moyen, Bernard
    Scott, Banks A.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (05): : 710 - 715
  • [4] Kinematic analysis of a posterior cruciate retaining mobile-bearing total knee arthroplasty
    Oakeshott, R
    Stiehl, JB
    Komistek, RA
    Anderson, DT
    Haas, BD
    JOURNAL OF ARTHROPLASTY, 2003, 18 (08): : 1029 - 1037
  • [5] Comparative analysis and validation of posterior cruciate ligament management in mobile-bearing total knee arthroplasty: Meta-analysis and animal study
    Zhang, Yuan-Shi
    Li, Hao-Yu
    Zhai, Lei
    Zheng, Gui-Zhou
    Xing, Hong-Bo
    Du, Shi-Xin
    Li, Xue-Dong
    JOURNAL OF ORTHOPAEDIC SURGERY, 2024, 32 (03)
  • [6] In Vivo Kinematics of a Cruciate Retaining Mobile-bearing Total Knee Arthroplasty
    Lee, Yeon Soo
    Park, Sang Jin
    Song, Eun Kyoo
    Kim, Jin Soo
    Kim, Yoon Hyuk
    Witvoet, Sietske Wimke
    Garling, Eric Harald
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2011, 12 (02) : 361 - 366
  • [7] In vivo kinematics of a cruciate retaining mobile-bearing total knee arthroplasty
    Yeon Soo Lee
    Sang Jin Park
    Eun Kyoo Song
    Jin Soo Kim
    Yoon Hyuk Kim
    Sietske Wimke Witvoet
    Eric Harald Garling
    International Journal of Precision Engineering and Manufacturing, 2011, 12 : 361 - 366
  • [8] Kinematics of a cementless mobile bearing posterior cruciate ligament-retaining total knee arthroplasty
    Chouteau, J.
    Lerat, J.
    Testa, R.
    moyen, B.
    Fessy, M. H.
    Banks, S. A.
    KNEE, 2009, 16 (03): : 223 - 227
  • [9] Comparative study of fixation mode in total knee arthroplasty with preservation of the posterior cruciate ligament
    Gicquel, P
    Kempf, JF
    Gastaud, F
    Schlemmer, B
    Bonnomet, F
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (03): : 240 - 249
  • [10] The posterior cruciate ligament in total knee arthroplasty
    Sorger, JI
    Federle, D
    Kirk, PG
    Grood, E
    Cochran, J
    Levy, M
    JOURNAL OF ARTHROPLASTY, 1997, 12 (08): : 869 - 879