Lung cancer screening using multi-slice thin-section computed tomography and autofluorescence bronchoscopy

被引:61
|
作者
McWilliams, Annette M.
Mayo, John R.
Ahn, Myeong Im
MacDonald, Sharyn L. S.
Lam, Stephen C.
机构
[1] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
[2] Vancouver Gen Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[3] Catholic Univ Korea, St Vincents Hosp, Dept Radiol, Suwon, South Korea
关键词
lung neoplasms; tomography; X-ray computed; bronchoscopy; diagnostic imaging; cytology;
D O I
10.1097/01243894-200601000-00012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Thoracic computed tomography (CT) for lung cancer screening is sensitive for the detection of early peripheral lung cancer but is not sensitive for detecting central preinvasive and microinvasive cancer. Our hypothesis is that the use of a two-step strategy, using a sputum biomarker, may increase the detection rate of lung cancer by identifying individuals at highest risk. Methods: We completed a pilot study of 561 volunteer current or former smokers 50 years of age or older, with a smoking history of more than or equal to 30 pack years. All subjects received induced sputum examination and low-dose thoracic CT scan and were offered autofluorescence bronchoscopy. Results: CT detected 2408 pulmonary nodules, 80% of which were less than or equal to 4 mm in diameter. During 2-year follow-up, 95% of these nodules were stable or resolved, with only 4% showing growth at any time. A total of 28 cancers were detected in 22 subjects: 21 by CT scan and seven by autofluorescence bronchoscopy. Overall, 0.9% nodules were malignant, but growth on more than or equal to two CT scans increased the malignancy rate to 75%. The mean diameter of malignant nodules on detection was 12.8 mm (range, 3 to 36.4 mm). However, 18% of malignant nodules were less than or equal to 4 mm in diameter when first seen. Conclusions: Multi-detector row CT scanners found multiple small nodules in most subjects screened, but most were stable over the 2-year follow-up. Persistent interval growth increases the probability of malignancy from less than 1% to 75%. One quarter of detected cancers were CT occult and only seen with autofluorescence bronchoscopy. Prescreening using a sputum biomarker improved the detection rate of lung cancer from 3 to 5%.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 50 条
  • [1] Low-dose thin-section CT screening for lung cancer using a multi-slice CT scanner
    Machida, S
    Sato, C
    Nishino, S
    Otani, N
    Amano, H
    Yoshida, T
    Hiroshi, H
    Nakamoto, T
    Sasagawa, M
    Kaneko, N
    LUNG CANCER, 2005, 49 : S183 - S183
  • [2] Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease
    Schoepf, UJ
    Becker, CR
    Obuchowski, NA
    Rust, GF
    Ohnesorge, BM
    Kohl, G
    Schaller, S
    Modic, MT
    Rieser, MF
    EUROPEAN RADIOLOGY, 2001, 11 (10) : 1975 - 1985
  • [3] Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease
    Joseph U. Schoepf
    Christoph R. Becker
    Nancy A. Obuchowski
    Georg-Friedemann Rust
    Bernd M. Ohnesorge
    Gerhard Kohl
    Stefan Schaller
    Michael T. Modic
    Maximilian F. Reiser
    European Radiology, 2001, 11 : 1975 - 1985
  • [4] Lung cancer screening: has there been any progress? Computed tomography and autofluorescence bronchoscopy
    Lee, Pyng
    Sutedja, Tom G.
    CURRENT OPINION IN PULMONARY MEDICINE, 2007, 13 (04) : 243 - 248
  • [5] Screening of patients with chest pain by multi-slice computed tomography
    Pinto, I.
    Souza, A. G. M. R.
    Egito, E. S. T.
    Barbosa, M. A. O.
    Romano, E. R.
    Jatene, I. B.
    Souza, J. E. M. R.
    Jatene, I. B.
    EUROPEAN HEART JOURNAL, 2005, 26 : 103 - 104
  • [6] Multi-slice technology in computed tomography
    Dawson, P
    Lees, WR
    CLINICAL RADIOLOGY, 2001, 56 (04) : 302 - 309
  • [7] Multi-slice quantum Computed Tomography system using a MHSP
    Carramate, L. F. N. D.
    Oliveira, C. A. B.
    Silva, A. L. M.
    da Silva, A. M.
    dos Santos, J. M. F.
    Veloso, J. F. C. A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [8] Lung Growth in Infants and Toddlers Assessed by Multi-slice Computed Tomography
    Rao, Laxmi
    Tiller, Christina
    Coates, Cathy
    Kimmel, Risa
    Applegate, Kimberly E.
    Granroth-Cook, Janice
    Denski, Cheryl
    Nguyen, James
    Yu, Zhangsheng
    Hoffman, Eric
    Tepper, Robert S.
    ACADEMIC RADIOLOGY, 2010, 17 (09) : 1128 - 1135
  • [9] Coronary angiography with multi-slice computed tomography
    Nieman, K
    Oudkerk, M
    Rensing, BJ
    van Ooijen, P
    Munne, A
    van Geuns, RJ
    de Feyter, PJ
    LANCET, 2001, 357 (9256): : 599 - 603
  • [10] Coronary characterization in multi-slice computed tomography
    Toumoulin, C
    Boldak, C
    Garreau, M
    Boulmier, D
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 749 - 752