Newborn Screening of Inborn Errors of Metabolism by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: A Second-Tier Method with Improved Specificity and Sensitivity

被引:49
|
作者
Chalcraft, Kenneth R. [1 ]
Britz-McKibbin, Philip [1 ]
机构
[1] McMaster Univ, Dept Chem, Hamilton, ON L8S 4M1, Canada
基金
加拿大创新基金会;
关键词
SYRUP-URINE-DISEASE; DRIED BLOOD SPOTS; UNDERIVATIZED AMINO-ACIDS; QUANTITATIVE-ANALYSIS; RAPID DIAGNOSIS; LIQUID-CHROMATOGRAPHY; ESI-MS/MS; CE-MS; ACYLCARNITINES; DISORDERS;
D O I
10.1021/ac8020455
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advent of electrospray-ionization mass spectrometry (ESI-MS) has given rise to expanded newborn screening programs for the early detection of inborn errors of metabolism (IEM). Despite the benefit of high-throughput screening for disease prognosis, conventional ESI-MS methods are limited by inadequate specificity, complicated sample handling, and low positive predictive outcome that can contribute to a high rate of false-positives. Herein, we report a robust strategy for neonatal screening based on capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) that offers a convenient platform for the direct analysis of amino acids, acylcarnitines, and their stereoisomers from dried blood spot (DBS) extracts without chemical derivatization. On-line sample preconcentration with desalting by CE-ESI-MS allowed for improved concentration sensitivity when detecting poorly responsive metabolites in complex biological samples without ionization suppression or isomeric/ isobaric interferences. Method validation demonstrated that accurate yet precise quantification can be achieved for 20 different amino acid and acylcarnitine biomarkers associated with IEMs when using a single non-deuterated internal standard. CE-ESI-MS represents a promising second-tier method in newborn screening programs that is compatible with ESI-MS/MS technology in cases when improved specificity and sensitivity is warranted for diagnosis confirmation and subsequent monitoring.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 50 条
  • [1] A promising capillary electrophoresis-electrospray ionization-mass spectrometry method for carbohydrate analysis
    Maxwell, E. Jane
    Ratnayake, Chitra
    Jayo, Roxana
    Zhong, Xuefei
    Chen, David D. Y.
    ELECTROPHORESIS, 2011, 32 (16) : 2161 - 2166
  • [2] Determination of yessotoxins and pectenotoxins in shellfish by capillary electrophoresis-electrospray ionization-mass spectrometry
    de la Iglesia, P.
    Gago-Martinez, A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (02): : 221 - 228
  • [3] Feasibility of nonvolatile buffers in capillary electrophoresis-electrospray ionization-mass spectrometry of proteins
    Eriksson, JHC
    Mol, R
    Somsen, GW
    Hinrichs, WLJ
    Frijlink, HW
    de Jong, GJ
    ELECTROPHORESIS, 2004, 25 (01) : 43 - 49
  • [4] Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    Maxwell, E. Jane
    Chen, David D. Y.
    ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 25 - 33
  • [5] Positional and geometrical anionic isomer separations by capillary electrophoresis-electrospray ionization-mass spectrometry
    Nogami, C
    Sawada, H
    ELECTROPHORESIS, 2005, 26 (7-8) : 1406 - 1411
  • [6] Determination of Isoflavones in Legumes by QuEChERS-Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry
    Perez-Martin, Lara
    Bustamante-Rangel, Myriam
    Milagros Delgado-Zamarreno, Maria
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 117 - 123
  • [7] Analysis of the lipophilic peptaibol alamethicin by nonaqueous capillary electrophoresis-electrospray ionization-mass spectrometry
    Psurek, A
    Neusüss, C
    Pelzing, M
    Scriba, GKE
    ELECTROPHORESIS, 2005, 26 (22) : 4368 - 4378
  • [8] A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides
    Ullsten, S
    Zuberovic, A
    Wetterhall, M
    Hardenborg, E
    Markides, KE
    Bergquist, J
    ELECTROPHORESIS, 2004, 25 (13) : 2090 - 2099
  • [9] Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments
    Bonvin, Gregoire
    Schappler, Julie
    Rudaz, Serge
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 17 - 31
  • [10] A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tseng, MC
    Chen, YR
    Her, GR
    ELECTROPHORESIS, 2004, 25 (13) : 2084 - 2089