Analytical solutions for analysing pumping tests in a sub-vertical and anisotropic fault zone draining shallow aquifers

被引:24
|
作者
Dewandel, B. [1 ]
Aunay, B. [2 ]
Marechal, J. C. [1 ]
Roques, C. [3 ]
Bour, O. [3 ]
Mougin, B. [4 ]
Aquilina, L. [3 ]
机构
[1] Bur Rech Geol & Minieres, Water Dept, New Water Resource & Econ Unit, F-34000 Montpellier, France
[2] Bur Rech Geol & Minieres, French Reg Geol Survey Reunion Isl, F-97404 St Denis, France
[3] Univ Rennes 1, CNRS, OSUR Res Federat Geosci, UMR 6118, F-35042 Rennes, France
[4] Bur Rech Geol & Minieres, French Reg Geol Survey Brittany, F-35700 Rennes, France
关键词
Pumping test; Compartmented aquifer; Fault; Crystalline aquifer; Groundwater dating; HARD-ROCK AQUIFERS; DISCRETE FRACTURE NETWORK; HYDRAULIC CONDUCTIVITY; PRESSURE DISTRIBUTIONS; NONUNIFORM AQUIFERS; CONTINUUM MODEL; FLOW; WELL; VALIDATION; TRANSPORT;
D O I
10.1016/j.jhydrol.2013.11.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We present new analytical solutions for examining the influence, during a pumping test in a well, of an infinite linear and anisotropic strip-aquifer that drains shallow aquifers of different diffusivity and thickness. The whole system is confined and the aquifer geometry can be represented by a 'T', an aquifer geometry resembling a sub-vertical fault or a sub-vertical vein cross-cutting shallower aquifers. The proposed solutions are based upon an unconventional application of well-image theory, without limitation of the diffusivity contrast between the three domains. Solutions for drawdown were developed for the three domains, i.e. the strip-aquifer and the two shallow compartments, and flow signatures are discussed in detail and compared to numerical modelling. The proposed solutions are not shown to be exact solutions to the appropriate partial differential equation, but very good and useful approximations. The solutions were applied to a 63-day pumping test in a steep fault zone in crystalline aquifer rock of Brittany, France. After that, the flow contributions of the fault zone and of the shallow aquifers deduced from groundwater dating were compared to analytical solutions. The solutions and theoretical type-curve examples can help in understanding flow processes from tests conducted in settings that are similar to such a conceptual model. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 131
页数:17
相关论文
共 5 条
  • [1] Analytical solutions for analysing pumping tests near an infinite vertical and anisotropic fault zone based upon unconventional application of well-image theory
    Dewandel, Benoit
    Hakoun, Vivien
    Lanini, Sandra
    Ladouche, Bernard
    Lamotte, Claudine
    Marechal, Jean-Christophe
    ADVANCES IN WATER RESOURCES, 2022, 160
  • [3] On the use of analytical solutions to design pumping tests in leaky aquifers connected to a stream
    Christensen, Steen
    Zlotnik, Vitaly A.
    Tartakovsky, Daniel M.
    JOURNAL OF HYDROLOGY, 2010, 381 (3-4) : 341 - 351
  • [4] Parameter correlation study on two new analytical solutions for radially divergent tracer tests in two-zone confined aquifers with vertical dispersion effect
    Wang, Chen
    Huang, Ching-Sheng
    Tong, Chenchen
    Lee, Cheng-Haw
    ADVANCES IN WATER RESOURCES, 2023, 179
  • [5] A general analytical model for pumping tests in radial finite two-zone confined aquifers with Robin-type outer boundary
    Lin, Ye-Chen
    Yang, Shaw-Yang
    Fen, Chiu-Shia
    Yeh, Hund-Der
    JOURNAL OF HYDROLOGY, 2016, 540 : 1162 - 1175