3D reconstruction of 2D fluorescence histology images and registration with in vivo MR images: Application in a rodent stroke model

被引:33
|
作者
Stille, Maik [1 ,2 ,3 ]
Smith, Edward J. [2 ]
Crum, William R. [3 ]
Modo, Michel [2 ,4 ]
机构
[1] Univ Lubeck, Inst Med Engn, D-23562 Lubeck, Germany
[2] Kings Coll London, Inst Psychiat, Dept Neurosci, London SE5 9NU, England
[3] Kings Coll London, Inst Psychiat, Dept Neuroimaging, London SE5 8AF, England
[4] Univ Pittsburgh, McGowan Inst Regenerat Imaging, Dept Radiol, Pittsburgh, PA 15237 USA
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
Histology; Magnetic resonance imaging; Image registration; Rat; Stroke; Image analysis; Medical imaging; FOCAL CEREBRAL-ISCHEMIA; MOUSE-BRAIN; 3-DIMENSIONAL RECONSTRUCTION; VOLUME RECONSTRUCTION; BEHAVIORAL-ASSESSMENT; RAT; SECTIONS; ACCURACY; HISTOPATHOLOGY; SEGMENTATION;
D O I
10.1016/j.jneumeth.2013.06.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To validate and add value to non-invasive imaging techniques, the corresponding histology is required to establish biological correlates. We present an efficient, semi-automated image-processing pipeline that uses immunohistochemically stained sections to reconstruct a 3D brain volume from 2D histological images before registering these with the corresponding 3D in vivo magnetic resonance images (MRI). A multistep registration procedure that first aligns the "global" volume by using the centre of mass and then applies a rigid and affine alignment based on signal intensities is described. This technique was applied to a training set of three rat brain volumes before being validated on three normal brains. Application of the approach to register "abnormal" images from a rat model of stroke allowed the neurobiological correlates of the variations in the hyper-intense MRI signal intensity caused by infarction to be investigated. For evaluation, the corresponding anatomical landmarks in MR and histology were defined to measure the registration accuracy. A registration error of 0.249 mm (approximately one in-plane voxel dimension) was evident in healthy rat brains and of 0.323 mm in a rodent model of stroke. The proposed reconstruction and registration pipeline allowed for the precise analysis of non-invasive MRI and corresponding microstructural histological features in 3D. We were thus able to interrogate histology to deduce the cause of MRI signal variations in the lesion cavity and the pen-infarct area. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 50 条
  • [1] A method for registration and visualization of 3D MR images and 2D thermographic images for clinical application
    Gariba, MA
    Sanches, IJ
    Pardal, FC
    Bichinho, GL
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1280 - 1280
  • [2] Model-based 3D/2D Deformable Registration of MR Images
    Marami, Bahram
    Sirouspour, Shahin
    Capson, David W.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4880 - 4883
  • [3] Registration of Partially Focused Images for 2D and 3D Reconstruction of Oversized Samples
    Martisek, Dalibor
    Druckmllerova, Hana
    SCANNING, 2017,
  • [4] 2D/3D registration of neonatal brain images
    Vansteenkiste, Ewout
    Vandemeulebroucke, Jef
    Philips, Wilfried
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 272 - 279
  • [5] Optimizing bone extraction in MR images for 3D/2D gradient based registration of MR and X-ray images
    Markelj, Primo
    Tomazevic, Dejan
    Pernus, Franjo
    Likar, Botjan
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [6] Study on 3D Model Reconstruction of Vehicles from 2D Images
    Zhang, Huaishan
    Gao, Guanbin
    Li, Bo
    MACHINE DESIGN AND MANUFACTURING ENGINEERING III, 2014, : 625 - 628
  • [7] 3D grape bunch model reconstruction from 2D images
    Woo, Yan San
    Li, Zhuguang
    Tamura, Shun
    Buayai, Prawit
    Nishizaki, Hiromitsu
    Makino, Koji
    Kamarudin, Latifah Munirah
    Mao, Xiaoyang
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2023, 215
  • [8] 3D shape reconstruction from 2D images
    Hirano, Daisuke
    Funayama, Yusuke
    Maekawa, Takashi
    Computer-Aided Design and Applications, 2009, 6 (05): : 701 - 710
  • [9] 3D reconstruction of 2D ICT images by Matlab
    Wei Dongbo
    Li Dan
    Tang Qibo
    Xu Haijun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3949 - 3952
  • [10] Rigid 2D/3D registration of intraoperative digital X-ray images and preoperative CT and MR images
    Tomazevic, D
    Likar, B
    Pernus, F
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 507 - 517