Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery

被引:4
|
作者
Black, Daniel [1 ]
Corbett, Dean [2 ]
Roberts, Timothy V. [3 ,4 ]
Cronin, Brendan [5 ]
Smith, Pamela J. [6 ]
Janakiraman, D. Priya [6 ]
Jackson, Beth E. [6 ]
机构
[1] Sunshine Eye Clin, Birtinya, Qld, Australia
[2] Auckland Eye Ltd, Auckland, New Zealand
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[4] Vis Eye Inst, Sydney, NSW, Australia
[5] Queensland Eye Inst, South Brisbane, Qld, Australia
[6] Johnson & Johnson Surg Vis Inc, Santa Ana, CA USA
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
cataract surgery; IOL; preloaded delivery system; clinical handleability; IOL IMPLANTATION; INCISION SIZE; INJECTOR; ENDOPHTHALMITIS; MICROINCISION; PERFORMANCE; SURFACE;
D O I
10.2147/OPTH.S260925
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical handleability and acceptability of a novel preloaded intraocular lens (IOL) delivery system for implantation of the TECNIS ZCB00 IOL (Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA) during routine small-incision cataract surgery. Subjects and Methods: In this prospective, open-label, noncomparative, unilateral or bilateral, multicenter study, adult subjects with unilateral or bilateral cataracts scheduled for IOL implantation were enrolled. Surgeons and surgical technicians completed per-eye day-of-surgery and end-of-surgical-day questionnaires. The primary endpoint of the study was the rate of acceptable overall clinical performance of the preloaded IOL delivery system. Other endpoints included additional responses from the questionnaires, preimplantation incision size, and safety. Results: The study included 91 eyes that underwent cataract surgery and IOL implantation using the preloaded delivery system and were available for the 1-day postoperative visit. Five surgeons and 14 surgical technicians from four investigational sites participated in the study. The rate of acceptable overall clinical performance was 100% (91/91) of eyes, with most responses (78/91; 85.7%) being the highest possible rating of 5 (very satisfied). Favorable responses by most surgeons and surgical technicians regarding additional endpoints further highlighted the handleability and acceptability of the preloaded delivery system. No ocular adverse events or lens findings (ie, no cases of IOL instability, haptic breakage, IOL marking, or crimping) were reported. Conclusion: The results of this study demonstrated that this preloaded IOL delivery system was safe and effective during routine small-incision cataract surgery.
引用
收藏
页码:2291 / 2300
页数:10
相关论文
共 50 条
  • [1] The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery
    Jones, Jason J.
    Chu, Jeffrey
    Graham, Jacob
    Zaluski, Erge
    Rocha, Guillermo
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1123 - 1129
  • [2] Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery
    Acar, Banu
    Torun, Isil M.
    Acar, Suphi
    OPEN OPHTHALMOLOGY JOURNAL, 2018, 12 : 94 - 103
  • [3] Does the Use of a Preloaded Intraocular Lens Delivery System Improve Post-operative Refractive Outcomes for Cataract Surgery?
    Henry, Mary
    Patel, Nishal
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [4] The impact of preloaded intraocular lens implantation system (TECNIS iTec®) in routine cataract surgery in China: a time-motion analysis
    Song, Xudong
    Zhou, Jian
    Zhang, Guangbin
    Jia, Songbai
    Yuan, Jun
    Hu, Ke
    Liu, Xinhua
    Zeng, Mingbing
    Wang, Zhenyu
    Tan, Baoying
    Lu, Xingwei
    Lin, Ailing
    Hu, Xiaohan
    Xuan, Jianwei
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [5] The impact of preloaded intraocular lens implantation system (TECNIS iTec®) in routine cataract surgery in China: a time-motion analysis
    Xudong Song
    Jian Zhou
    Guangbin Zhang
    Songbai Jia
    Jun Yuan
    Ke Hu
    Xinhua Liu
    Mingbing Zeng
    Zhenyu Wang
    Baoying Tan
    Xingwei Lu
    Ailing Lin
    Xiaohan Hu
    Jianwei Xuan
    BMC Ophthalmology, 23
  • [6] Multicenter Evaluation of Time, Operational, and Economic Efficiencies of a New Preloaded Intraocular Lens Delivery System versus Manual Intraocular Lens Delivery
    Mendicute, Javier
    Bascaran, Lucia
    Pablo, Luis
    Schweitzer, Cedric
    Velasque, Laurent
    Bouchet, Christine
    Martinez, Aldo A.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 591 - 599
  • [7] Early clinical experience with a new preloaded one-piece intraocular lens in paediatric cataract surgery
    D B Gosling
    T K J Chan
    Eye, 2016, 30 : 1266 - 1267
  • [8] Early clinical experience with a new preloaded one-piece intraocular lens in paediatric cataract surgery
    Gosling, D. B.
    Chan, T. K. J.
    EYE, 2016, 30 (09) : 1266 - 1267
  • [9] Aspergillus Tubingenesis Endophthalmitis after Cataract Surgery with Implantation of Preloaded Intraocular Lens
    Kokuzawa, Satoko
    Suemori, Shinsuke
    Mochizuki, Kiyofumi
    Hirose, Yoshinobu
    Yaguchi, Takashi
    SEMINARS IN OPHTHALMOLOGY, 2014, 29 (04) : 218 - 221
  • [10] In vitro delivery performance assessment of a new preloaded intraocular lens delivery system
    Wang, Lixin
    Wolfe, Patricia
    Chernosky, Alexis
    Paliwal, Sumit
    Tjia, Khiun
    Lane, Stephen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1814 - 1820