Multi-camera systems use for dental arch shape measurement

被引:6
|
作者
Prochazka, Ales [1 ]
Kasparova, Magdalena [3 ]
Yadollahi, Mohammadreza [1 ]
Vysata, Oldrich [2 ]
Grajciarova, Lucie [1 ]
机构
[1] Inst Chem Technol, Dept Comp & Control Engn, Tech 5, CR-16628 Prague 6, Czech Republic
[2] Charles Univ Prague, Fac Med Hradec Kralove, Dept Neurol, Hradec Kralove 50005, Czech Republic
[3] Charles Univ Prague, Fac Med 2, Dept Stomatol, Prague 15006 5, Czech Republic
来源
VISUAL COMPUTER | 2015年 / 31卷 / 11期
关键词
Image acquisition; Multi-camera systems; Geometric modeling; Digital signal processing; Computational intelligence; Cleft palate; VIRTUAL-REALITY; SURGERY; LIP;
D O I
10.1007/s00371-014-1029-z
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
This paper presents the analysis of dental cast images and new mathematical methods for their evaluation. While depth sensors of sophisticated scanners allow precise spatial data processing, it is possible to use a multi-camera system for direct data acquisition and recognition of selected objects as well. The main goal of this paper is the analysis of three-dimensional objects to enable numerical evaluation of measurements important for proposals of the appropriate treatment after dental operations. Methods presented include (1) computer analysis of a single de-noised and thresholded image used for detection of its components and (2) presentation of tools for three-dimensional modeling using a double camera system. The proposed algorithms allow semi-automatic evaluation of measurements between selected objects. The resulting general algorithm can be used both in biomedical applications and engineering to detect measurements in static image frames or videosequences.
引用
收藏
页码:1501 / 1509
页数:9
相关论文
共 50 条
  • [1] Multi-camera systems use for dental arch shape measurement
    Aleš Procházka
    Magdaléna Kašparová
    Mohammadreza Yadollahi
    Oldřich Vyšata
    Lucie Grajciarová
    The Visual Computer, 2015, 31 : 1501 - 1509
  • [2] Erratum to: Multi-camera systems use for dental arch shape measurement
    Aleš Procházka
    Magdaléna Kašparová
    Mohammadreza Yadollahi
    Oldřich Vyšata
    Lucie Grajciarová
    The Visual Computer, 2017, 33 : 689 - 689
  • [3] Multi-camera systems use for dental arch shape measurement (vol 31, pg 1501, 2015)
    Prochazka, Ales
    Kasparova, Magdalena
    Yadollahi, Mohammadreza
    Vysata, Oldrich
    Grajciarova, Lucie
    VISUAL COMPUTER, 2017, 33 (05): : 689 - 689
  • [4] Calibration accuracy evaluation method for multi-camera measurement systems
    Yuan, Fang
    Xia, Zhiyuan
    Tang, Baijian
    Yin, Zhuoyi
    Shao, Xinxing
    He, Xiaoyuan
    MEASUREMENT, 2025, 242
  • [5] Calibration of Multi-Camera Systems
    Dondo, Diego Gonzalez
    Trasobares, Fernando
    Yoaquino, Leandro
    Padilla, Julian
    Redolfi, Javier
    2015 XVI WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2015,
  • [6] Multi-camera image measurement and correspondence
    Black, J
    Ellis, T
    MEASUREMENT, 2002, 32 (01) : 61 - 71
  • [7] CALIBRATION OF MULTI-CAMERA PHOTOGRAMMETRIC SYSTEMS
    Detchev, I.
    Mazaheri, M.
    Rondeel, S.
    Habib, A.
    ISPRS TECHNICAL COMMISSION I SYMPOSIUM, 2014, 40-1 : 101 - 108
  • [8] ANALYSIS OF NOISE IN MULTI-CAMERA SYSTEMS
    Stankiewicz, Olgierd
    Domanski, Marek
    Wegner, Krzysztof
    2014 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO (3DTV-CON), 2014,
  • [9] Pose Estimation for Multi-camera Systems
    Zhao, Chunhui
    Fan, Bin
    Hu, Jinwen
    Tian, Limin
    Zhang, Zhiyuan
    Li, Sijia
    Pan, Quan
    PROCEEDINGS OF 2017 IEEE INTERNATIONAL CONFERENCE ON UNMANNED SYSTEMS (ICUS), 2017, : 533 - 538
  • [10] Pose estimation for multi-camera systems
    Frahm, JM
    Köser, K
    Koch, R
    PATTERN RECOGNITION, 2004, 3175 : 286 - 293