Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented

被引:6
|
作者
Hernandez, Yanira [1 ]
Tarazona, Beatriz [1 ]
Zamora, Natalia [1 ]
Cibrian, Rosa [2 ]
Luis Gandia, Jose [1 ]
Paredes, Vanessa [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Orthodont, Valencia 46010, Spain
[2] Univ Valencia, Fac Med & Dent, Dept Physiol, Valencia 46010, Spain
关键词
CBCT; Tooth size; 3D models; BEAM COMPUTED-TOMOGRAPHY; RELIABILITY; IMAGES; MODELS;
D O I
10.1007/s11282-015-0204-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To develop a 3D cone-beam computed tomography (CBCT) method (CBCT method) for determining tooth sizes and arch dimensions and to compare the accuracy and reproducibility of that method with those of a previously described 3D segmented CBCT method (CBCT seg. method) and a 2D digital method. Plaster study models and CBCT images were available for 34 patients. For the first method, the plaster study casts were digitalized and measured using the 2D digital method. For the second method, CBCT seg. method, the CBCT images were sent in DICOM format to InVivoDental(A (R)) Company for segmentation and conversion into three-dimensional images of the models. For the third method, CBCT method, axial cuts were performed on the CBCT images, and tooth sizes and arch dimensions were measured using Anatomage(A (R)) software. Significant differences were found between the tooth size measurements obtained with the 3D CBCT method and the 2D digital method, but not for the intercanine width, intermolar width, and arch length. There were no significant differences between the measurements obtained with the CBCT seg. method and the 2D digital method. A 3D CBCT method has been developed. It presented good accuracy for the intercanine width, intermolar width, and arch length, but not for the mesiodistal tooth sizes. Model segmentation will be necessary for measurements of tooth size.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 50 条
  • [1] Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented
    Yanira Hernandez
    Beatriz Tarazona
    Natalia Zamora
    Rosa Cibrian
    Jose Luis Gandia
    Vanessa Paredes
    Oral Radiology, 2015, 31 : 165 - 172
  • [2] Evaluating the accuracy of facial models obtained from volume wrapping: 2D images on CBCT versus 3D on CBCT
    Almulla, Soghyia
    Premjani, Pratik
    Vaid, Nikhilesh R.
    Fadia, Dhaval F.
    Ferguson, Donald J.
    SEMINARS IN ORTHODONTICS, 2018, 24 (04) : 443 - 450
  • [3] 3D accuracy of deciduous tooth model reconstructed from CBCT scan
    Li, Hongbo
    Liu, Lin
    Gao, Yuxuan
    Shi, Xiaowei
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 798 - +
  • [4] Comparative irradiation between peroperative 2D C-arm and 3D CBCT in children: a study on phantoms
    Prod'homme, Marc
    Sans-Merce, Marta
    Pitteloud, Nicolas
    Damet, Jerome
    Lascombes, Pierre
    SWISS MEDICAL WEEKLY, 2018, 148 : 59S - 59S
  • [5] A comparison between 2D and 3D cephalometry on CBCT scans of human skulls
    van Vlijmen, O. J. C.
    Maal, T.
    Berge, S. J.
    Bronkhorst, E. M.
    Katsaros, C.
    Kuijpers-Jagtman, A. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (02) : 156 - 160
  • [6] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308
  • [7] 3D printing and CBCT anatomical reproducibility assessment in forensic scenarios
    Queiroz-Fontes, Rebeca
    Ribeiro, Patricia
    Nunes, Tiago
    Nogueira, Andre
    Marques, Jeidson
    Corte-Real, Ana
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2024, 106
  • [8] Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software
    Aksoy, Secil
    Kelahmet, Umay
    Hincal, Evren
    Oz, Ulas
    Orhan, Kaan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (04) : 777 - 784
  • [9] A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup
    Guan, Huaiqun
    Hammoud, Rabih
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 273 - 280
  • [10] 3D versus 2D/3D shape descriptors:: A comparative study
    Zaharia, T
    Prêteux, F
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS III, 2004, 5298 : 47 - 58