Clinical Study on Efficiency of Using Traditional Direct Bonding or OrthGuide Computer-Aided Indirect Bonding in Orthodontic Patients

被引:2
|
作者
Wang, Min [1 ]
Shi, Xing [1 ]
Cheng, Wei-Pu [1 ]
Ma, Fei-Hu [1 ]
Cheng, Si-Miao [2 ]
Kang, Xuan [2 ]
机构
[1] RYTIME Dent, Beijing 100000, Peoples R China
[2] Shenzhen Becoming Digital Dent Co Ltd, Shenzhen 518000, Peoples R China
关键词
HEALTH;
D O I
10.1155/2022/9965190
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. This study aims to clinically investigate and compare the therapeutic effects and treatment cycle between traditional direct bonding and OrthGuide computer-aided indirect bonding in orthodontic treatment. Methods. Forty patients treated at the Department of Orthodontics, Beijing Rytime Dental Hospital between July 1, 2016, and December 31, 2019, were included. The patients were divided into a control group (n=20, traditional direct bonding) and a test group (n=20, OrthGuide computer-aided indirect bonding). The American Board of Orthodontics (ABO) measurement was performed on patients using Uceph cephalometric analysis software to compare intragroup and intergroup differences, and the treatment cycles of all patients were recorded. Results. After treatment, U1-NA (mm), & ANGLE;U1-SN (& DEG;), LL-EP (mm), and UL-EP (mm) in the control group were significantly lower than before treatment, and there was no significant difference in other ABO measurement indexes, while the test group showed no marked difference in all ABO measurements between pre- and posttreatment. Further, intergroup comparison showed no significant difference in ABO measurements in pre- and posttreatment between the two groups. The test group had a shorter treatment cycle than the control group, with an average treatment cycle of 21.20 & PLUSMN;7.14 months in the control group and 17.17 & PLUSMN;4.16 months in the test group. Conclusion. There was no significant difference in the therapeutic effects between the direct and indirect bonding techniques. However, OrthGuide computer-assisted indirect bonding demonstrated a significantly shorter treatment cycle and might be more efficient than traditional direct bonding.
引用
收藏
页数:5
相关论文
共 36 条
  • [1] Computer-aided indirect bonding versus traditional direct bonding of orthodontic brackets: bonding time, immediate bonding failures, and cost-minimization. A randomized controlled trial
    Czolgosz, Izabela
    Cattaneo, Paolo M.
    Cornelis, Marie A.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2021, 43 (02) : 144 - 151
  • [2] Evaluation of the Failure Rate and Clinical Efficacy of Orthodontic Brackets Indirect Bonding with Computer-Aided Transfer Jig System: An In Vivo Study
    Bai, Jin
    Lee, Hye-Jin
    Kim, Seong-Hun
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [4] Evaluation of effectiveness and efficiency of fixed orthodontic treatment comparing standard and computer-aided design and manufacturing conventional bracket systems using indirect bonding for both: A retrospective study
    Palone, Mario
    Bizzocchi, Chiara
    Guiducci, Daniela
    Cremonini, Francesca
    Pellitteri, Federica
    Spedicato, Giorgio Alfredo
    Verducci, Alessandro
    Lombardo, Luca
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2023, 12 (06) : 251 - 259
  • [5] Measuring the accuracy of a computer-aided design and computer-aided manufacturing-based indirect bonding tray Response
    Xue, Chaoran
    Xu, Hui
    Guo, Yongwen
    Xu, Li
    Dhami, Yogyata
    Wang, Hongzhe
    Liu, Zhongyu
    Ma, Jianbin
    Bai, Ding
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 158 (03) : 316 - 316
  • [6] Standard vs computer-aided design/computer-aided manufacturing customized self-ligating systems using indirect bonding with both: A comparative study
    Jackers, Nastasia
    Maes, Nathalie
    Lambert, France
    Albert, Adelin
    Charavet, Carole
    ANGLE ORTHODONTIST, 2021, 91 (01) : 74 - 80
  • [7] Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients
    Kanwal, Leelan
    Idrees, Wafa
    Ahmed, Aqeel
    Sukhia, Rashna Hoshang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 162 (06) : 808 - 808
  • [8] Accurate bracket placement using a computer-aided design and computer-aided manufacturing-guided bonding device: An in vivo study
    Xue, Chaoran
    Xu, Hui
    Guo, Yongwen
    Xu, Li
    Dhami, Yogyata
    Wang, Hongzhe
    Liu, Zhongyu
    Ma, Jianbin
    Bai, Ding
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 157 (02) : 269 - 277
  • [9] Computer-aided design and computer-aided manufacturing indirect versus direct composite restorations: A randomized clinical trial
    Gomes Torres, Carlos Rocha
    Moreira Andrade, Adrielle Caroline
    Valente Pinho Mafetano, Ana Paula
    de Abreu, Fabricia Stabile
    Andrade, Danilo de Souza
    Mailart, Mariane Cintra
    Rocha Campello de Souza, Maria Luiza Aun de Barros Lima
    Alarca Nunes, Lilian Guimaraes
    Rodrigues de Araujo, Carlos Ariel
    Di Nicolo, Rebeca
    Borges, Alessandra Buhler
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 776 - 788
  • [10] Effectiveness, efficiency and adverse effects of using direct or indirect bonding technique in orthodontic patients: a systematic review and meta-analysis
    Li, Yanxi
    Mei, Li
    Wei, Jieya
    Yan, Xinyu
    Zhang, Xu
    Zheng, Wei
    Li, Yu
    BMC ORAL HEALTH, 2019, 19 (1)