Venturi-type fluidic sampler for liquid-solid mixtures

被引:1
|
作者
Xu, Cong [1 ]
Liu, Binbin [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
关键词
Sampler; Liquid-solid; Reverse flow diverter; Venturi principle; Maintenance free;
D O I
10.1016/j.partic.2011.09.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Static-type samplers are required for sampling corrosive, toxic, high-temperature, or radioactive liquid-solid fluids. We have designed a compact reverse flow diverter pumping system for transferring liquid-solid mixtures. In accordance with the Venturi principle, an acceptable volume of liquid-solid fluid is automatically collected into a sampling bottle. The effects of sampling needle sizes, sectional area of the T-section, solid concentration, and liquid viscosity on the performance of fluidic samplers were experimentally investigated. The sample volume increased upon the reduction of the sampling needle length and the increase of the sectional area of the T-section, but decreased with the increase of solid concentration and liquid viscosity. Unbiased samples of acceptable volume were produced by the proposed fluidic sampler, even at 10.21 mPa s liquid viscosity, 35 wt% solid concentration, and 6.74 m sampling height. (C) 2011 Chinese Society of Particuology and Institute of Process Engineering, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
  • [1] Venturi-type fluidic sampler for liquid-solid mixtures
    Cong Xu
    Particuology, 2012, 10 (03) : 283 - 291
  • [2] SOUND ATTENUATION IN LIQUID-SOLID MIXTURES
    DUYKERS, LRB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1967, 41 (05): : 1330 - +
  • [3] Experimental study on Venturi-type natural ventilator
    Kim, Yeong Sik
    Han, Dong Hun
    Chung, Hanshik
    Jeong, Hyomin
    Choi, Soon-Ho
    ENERGY AND BUILDINGS, 2017, 139 : 232 - 241
  • [4] AN ANALYSIS OF THE PERFORMANCE OF A VARIABLE VENTURI-TYPE OXYGEN MASK
    WOOLNER, DF
    LARKIN, J
    ANAESTHESIA AND INTENSIVE CARE, 1980, 8 (01) : 44 - 51
  • [5] Bubble breakup mechanism in Venturi-type bubble generator
    Shao Z.
    Zhang H.
    Sun L.
    Mo Z.
    Du M.
    Huagong Xuebao/CIESC Journal, 2018, 69 (06): : 2439 - 2445
  • [6] QUALITY DETERMINATION OF LIQUID-SOLID HYDROGEN MIXTURES
    DANEY, DE
    MANN, DB
    CRYOGENICS, 1967, 7 (05) : 280 - &
  • [7] COMMENTS ON SOUND ATTENUATION IN LIQUID-SOLID MIXTURES
    MCCANN, C
    MCCANN, DM
    DUYKERS, LRB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1968, 43 (02): : 381 - &
  • [8] THE HYDRODYNAMICS OF VENTURI-TYPE EMULSION GAS-LIQUID CONTACTORS FUNCTIONING IN SELF-ASPIRATION
    LABIT, C
    LEBEAULT, JM
    ZOULALIAN, A
    BESSON, G
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (04): : 663 - 666
  • [9] A review on bubble generation and transportation in Venturi-type bubble generators
    Huang, Jiang
    Sun, Licheng
    Liu, Hongtao
    Mo, Zhengyu
    Tang, Jiguo
    Xie, Guo
    Du, Min
    EXPERIMENTAL AND COMPUTATIONAL MULTIPHASE FLOW, 2020, 2 (03) : 123 - 134
  • [10] The CFD simulation and experiment of a venturi-type artificial downwelling device
    Lin, Tiancheng
    Xiao, Canbo
    Qiang, Yongfa
    Fan, Wei
    Pan, Hong
    OCEANS 2018 MTS/IEEE CHARLESTON, 2018,