Evaluation of the optic nerve head using confocal scanning laser ophthalmoscopy in patients with multiple sclerosis

被引:1
|
作者
Ugurlu, S [1 ]
Yurdakul, NS [1 ]
Demir, C [1 ]
Maden, A [1 ]
机构
[1] Ataturk Educ & Res Hosp, Dept Ophthalmol, Izmir, Turkey
关键词
multiple sclerosis; confocal scanning laser ophthalmoscopy; optic neuropathy;
D O I
10.1080/01658100600599535
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose : To study optic nerve head parameters of patients with definite multiple sclerosis (MS) using confocal scanning laser ophthalmoscopy. Methods : Twenty-one consecutive patients with definite MS were evaluated with Heidelberg Retina Tomograph II (version 1.5) between January and June 2003. Optic nerve head stereometric parameters of eyes without prior optic neuropathy (ON) were compared to an age- and sex-matched control group (n = 23). Eyes with prior ON were compared to their fellow eyes. A correlation between visual evoked potentials (VEP) and stereometric parameters was sought. Results : The average age of the 21 patients (11 females, 10 males) was 34.9 9 years. Eight eyes of eight patients (38%) had prior ON. Rim volume ( p = 0.04), average retinal nerve fiber layer thickness ( p = 0.002), and nerve fiber layer surface area ( p = 0.000) values of 21 eyes of 21 MS patients without prior ON were lower than those of the control group. No statistically significant difference was noted between eyes with prior ON and their fellow eyes regarding optic nerve head parameters. No correlation was found between stereometric parameters and VEP results. Conclusions : MS patients without prior ON show a deviation from normal with regard to some of the optic nerve head stereometric parameters.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [1] Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy
    Zangwill, LM
    vanHorn, S
    Lima, MD
    Sample, PA
    Weinreb, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (04) : 520 - 525
  • [2] Confocal scanning laser ophthalmoscopy and the screening of optic nerve pathology
    Alyabyeva, Zh. Yu.
    Agaptseva, O. V.
    2018 INTERNATIONAL CONFERENCE LASER OPTICS (ICLO 2018), 2018, : 521 - 521
  • [3] The "ISN'T Rule" in Healthy Participant Optic Nerve Head by Confocal Scanning Laser Ophthalmoscopy
    Iester, Michele
    Bertolotto, Marina
    Recupero, Santo M.
    Perdicchi, Andrea
    JOURNAL OF GLAUCOMA, 2011, 20 (06) : 350 - 354
  • [4] Effect of the menstrual cycle on the optic nerve head in diabetes: analysis by confocal scanning laser ophthalmoscopy
    Akar, ME
    Yucel, I
    Erdem, U
    Taskin, O
    Ozel, A
    Akar, Y
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2005, 40 (02): : 175 - 182
  • [5] Prospective Evaluation of Optic Nerve Head by Confocal Scanning Laser Ophthalmoscopy after Intraocular Pressure Control in Adult Glaucoma
    Rao, Aparna
    Sihota, Ramanjit
    Srinivasan, Geetha
    Gupta, Viney
    Gupta, Amisha
    Sharma, Ajay
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (01) : 13 - 18
  • [6] Glaucomatous optic nerve head changes with scanning laser ophthalmoscopy
    Marengo J.
    Ucha R.A.
    Martinez-Cartier M.
    Sampaolesi J.R.
    International Ophthalmology, 2001, 23 (4-6) : 413 - 423
  • [7] Optic nerve head analysis using confocal scanning laser ophthalmoscopy and spectral-domain optical coherence tomography
    Roberti, Gloria
    Oddone, Francesco
    Tanga, Lucia
    Michelessi, Manuele
    De Geronimo, Daniele
    Centofanti, Marco
    Manni, Gianluca
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Asymmetry of optic nerve head parameters measured by confocal scanning laser ophthalmoscopy in myopic anisometropic eyes
    Wang, Geng
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] Asymmetry of Optic Nerve Head Parameters Measured by Confocal Scanning Laser Ophthalmoscopy in Myopic Anisometropic Eyes
    Gong, Weifen
    Lu, Xuehui
    Wang, Geng
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [10] Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy
    Schuman, JS
    Wollstein, G
    Farra, T
    Hertzmark, E
    Aydin, A
    Fujimoto, JG
    Paunescu, LA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 504 - 512