Improving Fault Ride-Through Capability of Fixed-Speed Wind Turbine by Using Bridge-Type Fault Current Limiter

被引:96
作者
Firouzi, M. [1 ]
Gharehpetian, G. B. [2 ]
机构
[1] Azad Univ Res & Sci, Dept Elect Engn, Tehran 1233756568, Iran
[2] Amirkabir Univ Technol, Dept Elect Engn, Tehran 15914, Iran
关键词
Bridge-type fault current limiter (FCL); fault ride through (FRT); induction generator (IG); wind turbines; STABILITY; FARMS;
D O I
10.1109/TEC.2013.2248366
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interaction between wind turbines and grid results in increasing short-circuit level and fault ride-through (FRT) capability problem during fault condition. In this paper, the bridge-type fault current limiter (FCL) with discharging resistor is used for solving these problems. For this FCL, a control scheme is proposed, which uses the dc reactor current as control variable, to adjust the terminal voltage of induction generator (IG) without measuring any parameters of system. In this paper, the wind energy conversion system (WECS) is a fixed-speed system equipped with a squirrel-cage IG. The drivetrain is represented by a two-mass model. The analytical and simulation studies of the bridge-type FCL and proposed control scheme for limiting the fault current and improving FRT capability are presented and compared with the impact of the application of the series dynamic braking resistor (SDBR).
引用
收藏
页码:361 / 369
页数:9
相关论文
共 19 条
[1]  
Adkins B., 1975, GEN THEORY ALTERNATI
[2]   STABILITY SIMULATION OF WIND TURBINE SYSTEMS [J].
ANDERSON, PM ;
BOSE, A .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (12) :3791-3795
[3]   Fault ride-through of large wind farms using series dynamic braking resistors (March 2007) [J].
Causebrook, Andrew ;
Atkinson, David J. ;
Jack, Alan G. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :966-975
[4]  
Chapman S.J., 2001, Electric Machinery and Power System Fundamentals, P310
[5]  
CIGRE WG A3.10, 2006, A310 CIGRE WG
[6]   Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems [J].
Gautam, Durga ;
Vittal, Vijay ;
Harbour, Terry .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1426-1434
[7]   Real-time analysis of the transient response improvement of fixed-speed wind farms by using a reduced-scale STATCOM prototype [J].
Gaztanaga, Haizea ;
Etxeberria-Otadui, Ion ;
Ocnasu, Dan ;
Bacha, Seddik .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (02) :658-666
[8]   An analytical method for analysis of large-disturbance stability of induction generators [J].
Grilo, Ahda Pionkoski ;
Mota, Alexandre de Assis ;
Mota, Lia Toledo Moreira ;
Freitas, Walmir .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (04) :1861-1869
[9]  
Hee-Sang Ko, 2008, Journal of Electrical Engineering & Technology, V3, P254, DOI 10.5370/JEET.2008.3.2.254
[10]   Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances [J].
Holdsworth, L ;
Wu, XG ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) :343-352