Performance of compressed sensing-based iterative reconstruction for single-photon emission computed tomography from undersampled projection data: a simulation study in 123I-N-ω-fluoropropyI-2β-carbomethoxy-3β-(4-iodophenyl)nortropane imaging

被引:1
|
作者
Matsutomo, Norikazu [1 ]
Fukaya, Kaoru [2 ]
Hashimoto, Takeyuki [1 ]
Yamamoto, Tomoaki [1 ]
Sato, Eisuke [1 ]
机构
[1] Kyorin Univ Hosp, Fac Hlth Sci, Dept Med Radiol Technol, Tokyo, Japan
[2] Kyorin Univ Hosp, Dept Radiol, Tokyo, Japan
关键词
compressed sensing; dopamine transporter imaging; image reconstruction; I-123-N-omega-fluoropropyI-2 beta-carbomethoxy-3 beta-(4-iodophenyl); single-photon emission computed tomography; SPECT; CT; I-123-IOFLUPANE; PARKINSONISM; TIME;
D O I
10.1097/MNM.0000000000000938
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to investigate the efficacy of compressed sensing (CS)-based iterative reconstruction (CS-IR) from undersampled projection data in I- 123-N-omega-fluoropropyI-2 beta-carbomethoxy-3 beta-(4-iodophenyl)nortropane single-photon emission computed tomography (SPECT). Materials and methods We used the cylinder/sphere and the striatal digital phantom models. The number of projections was set at 120, 90, 60, 40, and 30 projections. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our CS algorithm. The efficacy of CS-IR was examined in terms of the spatial resolution, recovery coefficient, aspect ratio (ASR), activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio. Results As the number of projections decreased, the following results were observed. No differences of the spatial resolution and activity concentration linearity were observed between reconstruction methods. However, ASR for FBP slightly increased in contrast to ML-EM and CS-IR for which ASR remained constant. There were not any clear differences between recovery coefficients obtained from each reconstruction. The %CV obtained by CS-IR was significantly superior to that obtained by other reconstructions at all number of projections: for example, the %CV obtained by 60 projection CS-I R was equivalent to that obtained by 120 projection FBP and ML-EM. The specific binding ratio did not change with the number of projections, and there were no significant differences between FBP, ML-EM, and CS-IR. Conclusion We have demonstrated that CS-I R with decreased number of projections can provide a good image quality compared with commonly used SPECT reconstruction methods. This CS could help to reduce overall acquisition time in(123)I-N-omega-fluoropropyI-2 beta-carbomethoxy-3 beta-(4-iodophenyl)nortropane SPECT, particularly. (C) 2018 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:106 / 114
页数:9
相关论文
共 11 条
  • [1] Shape analysis of 123I-N-ω-fluoropropyl-2-β-carbomethoxy-3β-(4-iodophenyl) nortropane single-photon emission computed tomography images in the assessment of patients with parkinsonian syndromes
    Staff, Roger T.
    Ahearn, Trevor S.
    Wilson, Kevin
    Counsell, Carl E.
    Taylor, Kate
    Caslake, Robert
    Davidson, Joyce E.
    Gemmell, Howard G.
    Murray, Alison D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (03) : 194 - 201
  • [2] [123I]N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane single-photon emission computed tomography brain imaging in the diagnosis of dementia with Lewy bodies
    Walker, Zuzana
    Cummings, Jeffrey L.
    ALZHEIMERS & DEMENTIA, 2012, 8 (01) : 74 - 83
  • [3] Reduced brain serotonin transporter availability in major depression as measured by [123I]-2β-carbomethoxy-3β-(4-iodophenyl)tropane and single photon emission computed tomography
    Malison, RT
    Price, LH
    Berman, R
    van Dyck, CH
    Pelton, GH
    Carpenter, L
    Sanacora, G
    Owens, MJ
    Nemeroff, CB
    Rajeevan, N
    Baldwin, RM
    Seibyl, JP
    Innis, RB
    Charney, DS
    BIOLOGICAL PSYCHIATRY, 1998, 44 (11) : 1090 - 1098
  • [4] Displacement of serotonin and dopamine transporters by venlafaxine extended release capsule at steady state -: A [123I]2β-carbomethoxy-3β-(4-iodophenyl)-tropone single photon emission computed tomography imaging study
    Shang, Yili
    Gibbs, Megan A.
    Marek, Gerard J.
    Stiger, Thomas
    Burstein, Aaron H.
    Marek, Kenneth
    Seibyl, John P.
    Rogers, Janyce F.
    JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 2007, 27 (01) : 71 - 75
  • [5] 123I-FP-CIT SPECT [(123) I-2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl) nortropane single photon emission computed tomography] Imaging in a p.A53T α-synuclein Parkinson's disease cohort versus Parkinson's disease
    Koros, Christos
    Simitsi, Athina
    Prentakis, Andreas
    Beratis, Ion
    Papadimitriou, Dimitra
    Kontaxopoulou, Dionysia
    Fragkiadaki, Stella
    Papagiannakis, Nikolaos
    Seibyl, John
    Marek, Kenneth
    Papageorgiou, Sokratis G.
    Trapali, Xenia Geronicola
    Stamelou, Maria
    Stefanis, Leonidas
    MOVEMENT DISORDERS, 2018, 33 (11) : 1734 - 1739
  • [6] 123I-2-carbomethoxy-3-(4-iodophenyl)-N-(3-fluoropropyl) nortropane single photon emission computed tomography and 123I-metaiodobenzylguanidine myocardial scintigraphy in differentiating dementia with lewy bodies from other dementias: A comparative study
    Tiraboschi, Pietro
    Corso, Angelo
    Guerra, Ugo Paolo
    Nobili, Flavio
    Piccardo, Arnoldo
    Calcagni, Maria Lucia
    Volterrani, Duccio
    Cecchin, Diego
    Tettamanti, Mauro
    Antelmi, Luigi
    Vidale, Simone
    Sacco, Leonardo
    Merello, Maria
    Stefanini, Stefano
    Micheli, Anna
    Vai, Paola
    Capitanio, Selene
    Gabanelli, Sara Vincenzina
    Riva, Riccardo
    Pinto, Patrizia
    Biffi, Ave Maria
    Muscio, Cristina
    ANNALS OF NEUROLOGY, 2016, 80 (03) : 368 - 378
  • [7] Detection of reduced dopamine transporter availability by 123I-N-omega-fluoropropyl-2-beta-carbomethoxy-3-beta (4-iodophenyl) nortropane single-photon emission computed tomography in a patient of frontotemporal dementia with motor neuron disease
    Kobayashi, Ryota
    Hayashi, Hiroshi
    Kawakatsu, Shinobu
    Nagasawa, Hiroki
    Koyama, Shingo
    Ishizawa, Kenichi
    Otani, Koichi
    PSYCHOGERIATRICS, 2020, 20 (05) : 799 - 801
  • [8] Seasonal variation of availability of serotonin transporter binding sites in healthy female subjects as measured by [123I]-2β-carbomethoxy-3β-(4-iodophenyl)tropane and single photon emission computed tomography
    Neumeister, A
    Pirker, W
    Willeit, M
    Praschak-Rieder, N
    Asenbaum, S
    Brücke, T
    Kasper, S
    BIOLOGICAL PSYCHIATRY, 2000, 47 (02) : 158 - 160
  • [9] N-OMEGA-FLUOROALKYL ANALOGS OF (1R)-2-BETA-CARBOMETHOXY-3-BETA-(4-IODOPHENYL)-TROPANE (BETA-CIT) - RADIOTRACERS FOR POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGING OF DOPAMINE TRANSPORTERS
    NEUMEYER, JL
    WANG, SY
    GAO, YG
    MILIUS, RA
    KULA, NS
    CAMPBELL, A
    BALDESSARINI, RJ
    ZEAPONCE, Y
    BALDWIN, RM
    INNIS, RB
    JOURNAL OF MEDICINAL CHEMISTRY, 1994, 37 (11) : 1558 - 1561
  • [10] Striatal 123I-2β-carbomethoxy-3b-(4-iodophenyl)-N-(3-fluoropropyl)-nortropane single-photon emission computed tomography demonstrates nigral degeneration in the early stage of behavioural variant frontotemporal dementia: an autopsy case with frontotemporal lobar degeneration with trans-activation response DNA protein 43 type B
    Arafuka, Shusei
    Fujishiro, Hiroshige
    Iritani, Shuji
    Torii, Youta
    Miwa, Ayako
    Yabata, Hiroyuki
    Sekiguchi, Hirotaka
    Habuchi, Chikako
    Kawashima, Kunihiro
    Yoshida, Mari
    Iwasaki, Yasushi
    Ozaki, Norio
    PSYCHOGERIATRICS, 2022, 22 (04) : 580 - 585