Comparison of permanent 125I seeds implants with two different techniques in 500 cases of prostate cancer

被引:16
|
作者
Luis Guinot, Jose [1 ]
Vicente Ricos, Jose [2 ]
Isabel Tortajada, Maria [1 ]
Angel Santos, Miguel [1 ]
Casanova, Juan [2 ]
Clemente, Jose [1 ]
Samper, Josefa [1 ]
Santamaria, Paula [1 ]
Arribas, Leoncio [1 ]
机构
[1] Fdn Inst Valenciano Oncol IVO, Dept Radiat Oncol, Valencia 46009, Spain
[2] Fdn Inst Valenciano Oncol IVO, Dept Urol, Valencia 46009, Spain
关键词
LDR brachytherapy; permanent; prostate cancer; real-time; seeds; technique; EXTERNAL-BEAM RADIOTHERAPY; BIOCHEMICAL OUTCOMES; INTERSTITIAL BRACHYTHERAPY; FREE SURVIVAL; FOLLOW-UP; MONOTHERAPY; GUIDELINES; MEN;
D O I
10.5114/jcb.2015.53525
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To perform a comparative study of 500 consecutive 1251 seeds implants for intracapsular prostate carcinoma with two techniques differing in terms of both strand implantation and planning. Material and methods: From 2002 to 2007 we performed 250 implants with fixed stranded seeds (RapidStrand (TM)) and a preplanning system and from 2007 to 2010, 250 with real-time and ProLink (TM) system. Mean age was 68 and 66, respectively, median PSA (prostate-specific antigen) 7.3 and 7.2, stage T1-T2a in 98% and 94%, and Gleason <= 6 in 96% and 86%. Low risk cases were 81% and 71%. The prescribed dose was 145 Gy to the prostate volume, or 108 Gy plus EBRT 46 Gy in some intermediate risk cases. Hormonal treatment was given to 42% and 28%. Results: Median follow-up was 48 and 47 months, respectively, 14 patients in the first group and 7 patients in the second developed biochemical failure (BF). Actuarial biochemical relapse-free survival (bRFS) at 5 years increased from 90.2% to 97.2% (low risk from 91.3% to 97.2%, intermediate risk from 84.2% to 97.1%). Biochemical failure was independent of hormone treatment. Rectal complications were G1-2 in 1.2% and 5.2%, respectively. A urinary catheter was necessary in 6.9% and 9.6%, and urethral resection in 1.9% and 4.4%. Genitourinary toxicity was G1-2 in 4.6% and 12%, G3-4 in 1.9% and 4.8%. An assessment of mean D-90 in a sample of patients showed that the dosimetry in postoperative planning based on CT improved from a mean D-90 of 143 Gy to 157 Gy. Conclusions: The outcome of patients with low risk prostate carcinoma treated with 1251 seed is very good with low complications rate. The real-time approach in our hands achieved a more precise seed implantation, better dosimetry, and a statistically non-significant better biochemical control. We have made this our standard technique.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [1] Comparison of permanent 125-I seeds implants with two different techniques in 500 cases of prostate cancer
    Guinot, J. L.
    Ricos, J. V.
    Tortajada, M. I.
    Santos, M. A.
    Perez, J.
    Martos, A.
    Guardino, C.
    De los Dolores, V.
    Gonzalez, V.
    Casanova, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S158 - S158
  • [2] Implementation of a quality control protocol for 125I seeds of permanent prostate Brachytherapy implants
    Pirraco, R
    Pereira, A
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S136
  • [3] Scintigraphic detection of 125I seeds after permanent brachytherapy for prostate cancer
    Kono, Yuzuru
    Kubota, Kazuo
    Mitsumoto, Takuya
    Tanaka, Akitomo
    Ishibashi, Akihiko
    Kobayashi, Kazumi
    Ito, Kimiteru
    Itami, Jun
    Kanemura, Mikio
    Minowada, Shigeru
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (04) : 541 - 545
  • [4] Comparison of two different types of stranded 125-I seeds for permanent prostate brachytherapy
    Polat, B.
    Glatz, S.
    Baier, K.
    Noe, M.
    Flentje, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S567 - S567
  • [5] The technique of 125I permanent implants
    Maurer, U
    Eble, MJ
    CONTROVERSIES IN URO-ONCOLOGY, 2002, 36 : 159 - 165
  • [6] Comparison of rectal wall dosimetry of loose seeds and stranded seeds in 125I permanent implant for low risk prostate cancer
    Saibishkumar, E. P.
    Yeung, I.
    Borg, J.
    Cummins-Holder, C.
    Landon, A.
    Beiki-Ardakani, A.
    Crook, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S343 - S344
  • [7] Idealized line source configuration for permanent 125I prostate implants
    Leclerc, G
    Lavallée, MC
    Tubic, D
    Métivier, J
    Vigneault, É
    Beaulieu, L
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 (02) : 213 - 220
  • [8] SEQUENTIAL COMPARISON OF SEED LOSS AND PROSTATE DOSIMETRY OF STRANDED SEEDS WITH LOOSE SEEDS IN 125I PERMANENT IMPLANT FOR LOW-RISK PROSTATE CANCER
    Saibishkumar, Elantholi P.
    Borg, Jette
    Yeung, Ivan
    Cummins-Holder, Cheryl
    Landon, Angela
    Crook, Juanita
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01): : 61 - 68
  • [9] Seed displacements after permanent I-125 brachytherapy for prostate cancer - Comparison of seeds in different prostate areas
    Pinkawa, M.
    Gagel, B.
    Asadpour, B.
    Piroth, M. D.
    Klotz, J.
    Borchers, H.
    Jakse, G.
    Eble, M. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S347 - S347
  • [10] Rectal dose in 103PD and 125I permanent prostate implants
    Lief, EP
    Wang, X
    Cha, CM
    Potters, L
    RADIOLOGY, 1998, 209P : 157 - 157