Minimum effective volume of ropivacaine 7.5mg/ml for an ultrasound-guided infraclavicular brachial plexus block

被引:13
|
作者
Flohr-Madsen, S. [1 ,2 ]
Ytrebo, L. M. [1 ,2 ]
Kregnes, S. [1 ,2 ]
Wilsgaard, T. [3 ]
Klaastad, O. [1 ,2 ]
机构
[1] Univ Hosp North Norway, Dept Anaesthesiol, N-9038 Tromso, Norway
[2] Univ Tromso, Inst Clin Med, Tromso, Norway
[3] Univ Tromso, Dept Community Med, Tromso, Norway
关键词
EFFECTIVE ANESTHETIC VOLUME; NERVE-STIMULATION; GUIDANCE; LIDOCAINE;
D O I
10.1111/aas.12078
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Ultrasound guidance has been shown to reduce the minimum effective volume (MEV) of local anaesthetics for several peripheral nerve blocks. Although the lateral sagittal infraclavicular block (LSIB) is a well-established anaesthesia method, MEV for this technique has not been established. Our aim with this study was to determine the MEV using ropivacaine 7.5mg/ml for the LSIB method. Methods Twenty-five adult American Society of Anesthesiologists physical status I-II patients scheduled for hand surgery received an ultrasound-guided LSIB with ropivacaine 7.5mg/ml. A successful block was defined as anaesthesia or analgesia for all five sensory nerves distal to the elbow, 30min after local anaesthetic injection. The MEV for a successful block in 50% of the patients was determined by using the staircase up-and-down method introduced by Dixon and Massey. Logistic regression and probit transformation were applied to estimate the MEV for a successful block in 95% of the patients. Results The patients received ropivacaine 7.5mg/ml volumes in the range of 12.530ml. The MEVs in 50% and 95% of the patients were 19ml [95% confidence interval (CI), 1427] and 31ml (95% CI, 1845), respectively. Conclusions For surgery distal to the elbow, the MEV in 95% of patients for an ultrasound-guided LSIB with ropivacaine 7.5mg/ml was estimated to be 31ml (95% CI, 1845ml). Further studies should determine the factors that influence the volume of local anaesthetic required for a successful infraclavicular block.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 50 条
  • [1] Minimum Effective Volume of 0.75% Ropivacaine for Ultrasound-Guided Axillary Brachial Plexus Block
    Vadagandla, Koti
    Jahagirdar, Vinay
    Rama, Kaanthi
    Qavi, Danish
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (12)
  • [2] The Minimum Effective Anesthetic Volume of 0.75% Ropivacaine in Ultrasound-Guided Interscalene Brachial Plexus Block
    Gautier, Philippe
    Vandepitte, Catherine
    Ramquet, Caroline
    DeCoopman, Mieke
    Xu, Daquan
    Hadzic, Admir
    ANESTHESIA AND ANALGESIA, 2011, 113 (04): : 951 - 955
  • [3] Minimum effective volume of bupivacaine 0.5% for ultrasound-guided retroclavicular approach to infraclavicular brachial plexus block
    Kayakli, Ali Sait
    Arslan, Nilgun Kavrut Ozturk E. Ulku
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2019, 69 (03): : 253 - 258
  • [4] PERINEURAXIAL DEXMEDETOMIDINE DECREASES THE MINIMUM EFFECTIVE VOLUME OF ROPIVACAINE FOR ULTRASOUND-GUIDED SUPRACLAVICULAR BRACHIAL PLEXUS BLOCK
    Qian, X.
    Zhao, H.
    Rao, Y.
    Nan, Y.
    Wang, Z.
    Wang, X.
    Lian, Q.
    Li, J.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 646 - 646
  • [5] Perineuraxial dexmedetomidine decreases the minimum effective volume of ropivacaine for ultrasound-guided supraclavicular brachial plexus block
    Qian, Xiaowei
    Zhao, Hang
    Rao, Yuquan
    Nan, Yang
    Wang, Zhongsu
    Wang, Xiaoqing
    Lian, Qingquan
    Li, Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (10): : 19461 - 19467
  • [6] Ultrasound-guided infraclavicular brachial plexus block
    Sandhu, NS
    Capan, LM
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (02) : 254 - 259
  • [7] Ultrasound-guided infraclavicular brachial plexus block
    Nadig, M
    Ekatodramis, G
    Borgeat, A
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (01)
  • [8] Minimum effective volume of 0.5% ropivacaine for ultrasound-guided costoclavicular brachial plexus block A dose finding study
    Wong, Ming H.
    Karmakar, Manoj K.
    Mok, Louis Y. H.
    Songthamwat, Banchobporn
    Samy, Winnie
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (09) : 780 - 786
  • [9] The 90% minimum effective volume of 0.5 ropivacaine for ultrasound-guided supra-clavicular brachial plexus block
    Xuan, Qinghang
    Pan, Ruoying
    Wang, Ai
    Li, Ruoyu
    Yang, Xuemei
    Yin, Guangfen
    ANAESTHESIOLOGIE, 2023, 72 : S39 - S43
  • [10] Minimum Effective Volume of Lidocaine for Ultrasound-Guided Infraclavicular Block
    Tran, De Q. H.
    Dugani, Shubada
    Dyachenko, Alina
    Correa, Jose A.
    Finlayson, Roderick J.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2011, 36 (02) : 190 - 194