Effect of Humidity on Cerium-based Conversion Coatings on Al 7075-T6

被引:3
|
作者
Joshi, S. [1 ]
Fahrenholtz, W. G. [1 ]
O'Keefe, M. J. [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Mat Sci & Engn, Mat Res Ctr, Rolla, MO 65409 USA
来源
关键词
ALUMINUM-ALLOY; CORROSION;
D O I
10.1149/1.3496433
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Cerium-based conversion coatings and Al 7075-T6 were exposed to 85% relative humidity at 40 degrees C to simulate ASTM B117 corrosion testing without NaCl. As-deposited coatings with cracks >0.5 mu m wide showed a significant increase in impedance from similar to 5 k Omega-cm(2) before exposure to similar to 95 k Omega-cm(2) after 168 hours of exposure compared to phosphate post-treated coatings (from similar to 60 to 90 k Omega-cm(2)) with cracks <0.5 mu m. The impedance of bare Al 7075-T6 increased from similar to 10 k Omega-cm(2) before exposure to similar to 275 k Omega-cm(2) after 168 hours of exposure. The increase in impedance in all cases was due to an altered layer containing Al and O on exposed alloy surfaces. X-ray photoelectron spectroscopy indicated that exposure to humidity reduced Ce(IV) to Ce(III) on as-deposited coatings, whereas post-treated coatings did not show any change in Ce oxidation state. Despite the increase in impedance, only post-treated coatings were able to inhibit corrosion in salt spray testing.
引用
收藏
页码:217 / 228
页数:12
相关论文
共 50 条
  • [1] Alkaline activation of Al 7075-T6 for deposition of cerium-based conversion coatings
    Joshi, Simon
    Fahrenholtz, William G.
    O'Keefe, Matthew J.
    SURFACE & COATINGS TECHNOLOGY, 2011, 205 (17-18): : 4312 - 4319
  • [2] The effect of surface pre-treatments on corrosion behavior of cerium-based conversion coatings on Al 7075-T6
    Danaee, I.
    Zamanizadeh, H. R.
    Fallahi, M.
    Lotfi, B.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2014, 65 (08): : 815 - 819
  • [3] Dissolution of cerium from cerium-based conversion coatings on Al 7075-T6 in 0.1 M NaCl solutions
    Joshi, Simon
    Kulp, Elizabeth A.
    Fahrenholtz, William G.
    O'Keefe, Matthew J.
    CORROSION SCIENCE, 2012, 60 : 290 - 295
  • [4] Characterization of Localized Surface States of Al 7075-T6 during Deposition of Cerium-Based Conversion Coatings
    Treu, Becky L.
    Joshi, Simon
    Pinc, William R.
    O'Keefe, Matthew J.
    Fahrenholtz, William G.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2010, 157 (08) : C282 - C287
  • [5] Characterization of Cerium-Based Conversion Coatings on Al 7075-T6 Deposited from Chloride and Nitrate Salt Solutions
    Joshi, Simon
    Treu, Becky L.
    O'Keefe, Matthew J.
    Fahrenholtz, William G.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2011, 158 (03) : C88 - C93
  • [6] Deposition and characterization of cerium oxide conversion coatings on aluminum alloy 7075-T6
    Rivera, BE
    Johnson, BY
    O'Keefe, MJ
    Fahrenholtz, WG
    SURFACE & COATINGS TECHNOLOGY, 2004, 176 (03): : 349 - 356
  • [7] Effect of Gelatin on the Performance of Cerium-based Conversion Coatings
    Liu, Haoquan
    Wang, Xin
    Xu, JiHui
    Liu, Qiang
    Gu, Songtao
    Jiang, Guijun
    Zhou, Meng
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES II, PTS 1 AND 2, 2009, 79-82 : 951 - 954
  • [8] CORROSION RESISTANCE OF CERIUM-CONVERSION COATINGS FORMED FROM CERIUM(III) SALTS ON ALUMINIUM ALLOY 7075-T6
    Rodic, Peter
    Milosev, Ingrid
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2020, 65 (03): : 227 - 244
  • [9] Effect of humidity on growth behavior of a fatigue crack of 7075-T6 extruded Al alloy
    Daiichi Univ., Coll. of Tech., Kokubu-chuo, Kirishima, 899-4395, Japan
    不详
    不详
    不详
    Zairyo, 8 (712-718):
  • [10] Microelectrochemical Testing of Cerium-Based Conversion Coatings
    Joshi, S.
    Fahrenholtz, W. G.
    O'Keefe, M.
    COATINGS FOR CORROSION PROTECTION, 2010, 25 (29): : 19 - 30