Microinjection molding of thermoplastic polymers: morphological comparison with conventional injection molding

被引:81
|
作者
Giboz, Julien [1 ,2 ]
Copponnex, Thierry [2 ]
Mele, Patrice [1 ]
机构
[1] Univ Savoie, LMOPS UMR CNRS 5041, F-73376 Le Bourget Du Lac, France
[2] Haute Ecole Arc Ingn, CH-2610 St Imier, Switzerland
关键词
HIGH-DENSITY POLYETHYLENE; SHEAR-INDUCED CRYSTALLIZATION; FLOW-INDUCED CRYSTALLIZATION; MECHANICAL-PROPERTIES; RANDOM COPOLYMERS; MOLDED POLYPROPYLENE; MICRO-CHANNELS; ORIENTATION; MICROSTRUCTURE; SIMULATION;
D O I
10.1088/0960-1317/19/2/025023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The skin-core crystalline morphology of injection-molded semi-crystalline polymers is well documented in the scientific literature. The thermomechanical environment provokes temperature and shear gradients throughout the entire thickness of the part during molding, thus influencing the polymer crystallization. Crystalline morphologies of a high-density polyethylene (HDPE) micromolded part (mu part) and a classical part (macropart) are compared with optical, thermal and x-ray diffraction analyses. Results show that the crystalline morphologies with regard to thickness vary between the two parts. While a 'skin-core' morphology is present for the macropart, the mu part exhibits a specific 'core-free' morphology, i.e. no spherulite is present at the center of the thickness. This result seems to be generated under the specific conditions used in microinjection molding that lead to the formation of smaller and more oriented crystalline entities.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Morphological evolution of HDPE parts in the microinjection molding: Comparison with conventional injection molding
    Guo, Chao
    Liu, Fang Hui
    Wu, Xian
    Liu, Hong
    Zhang, Jie
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 126 (02) : 452 - 462
  • [2] Microinjection molding of thermoplastic polymers:: a review
    Giboz, Julien
    Copponnex, Thierry
    Mele, Patrice
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (06) : R96 - R109
  • [3] Morphological comparison of isotactic polypropylene parts prepared by micro-injection molding and conventional injection molding
    Liu, Fanghui
    Guo, Chao
    Wu, Xian
    Qian, Xinyuan
    Liu, Hong
    Zhang, Jie
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2012, 23 (03) : 686 - 694
  • [4] Comparison of Molding Characteristics for Multi-cavity Molding in Conventional Injection Molding and Injection Compression Molding
    Lee, Dan Bi
    Nam, Yun Hyo
    Lyu, Min-Young
    POLYMER-KOREA, 2014, 38 (02) : 144 - 149
  • [5] Comparison and Analysis on Cavity Pressure of Conventional Injection Molding and Injection Compression Molding
    Wang Tao
    Ge Yong
    Lang Jian-lin
    Sun Qi-wei
    Li Lei
    Yan Yue
    CAILIAO GONGCHENG-JOURNAL OF MATERIALS ENGINEERING, 2018, 46 (04): : 127 - 133
  • [6] Modeling of morphology evolution in the injection molding process of thermoplastic polymers
    Pantani, R
    Coccorullo, I
    Speranza, V
    Titomanlio, G
    PROGRESS IN POLYMER SCIENCE, 2005, 30 (12) : 1185 - 1222
  • [7] ON THE PACKING HOLDING FLOW IN THE INJECTION-MOLDING OF THERMOPLASTIC POLYMERS
    TITOMANLIO, G
    PICCAROLO, S
    LEVATI, G
    JOURNAL OF APPLIED POLYMER SCIENCE, 1988, 35 (06) : 1483 - 1495
  • [8] Modeling Morphology Evolution during Injection Molding of Thermoplastic Polymers
    Pantani, R.
    De Santis, F.
    Speranza, V.
    Titomanlio, G.
    PROCEEDINGS OF PPS-30: THE 30TH INTERNATIONAL CONFERENCE OF THE POLYMER PROCESSING SOCIETY, 2015, 1664
  • [9] Design of a Multi Microinjection Molding Module for Thermoplastic Polymer
    Zhang, Panpan
    Wang, Jian
    Xie, Pengcheng
    Miao, Lilei
    Yang, Weimin
    PROGRESS IN POLYMER PROCESSING, 2012, 501 : 162 - +
  • [10] Morphological comparison of isotactic polypropylene molded by water-assisted and conventional injection molding
    Xianhu Liu
    Guoqiang Zheng
    Kun Dai
    Zhenhua Jia
    Songwei Li
    Chuntai Liu
    Jingbo Chen
    Changyu Shen
    Qian Li
    Journal of Materials Science, 2011, 46 : 7830 - 7838