Cost study on remote source solar lighting system in high-rise residential buildings in Hong Kong

被引:12
|
作者
Wong, Irene [1 ]
Yang, H. X. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, RERG, Kowloon, Hong Kong, Peoples R China
关键词
Remote source solar lighting system; High-rise residential buildings; Central core design; Enclosed lift lobby; Side-emitting fiber optic; ENCLOSED LIFT LOBBIES; ENERGY USE;
D O I
10.1016/j.buildenv.2013.05.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hong Kong is a densely populated metropolitan city with limited land supply. The land cost is high. Majority of the residential buildings are developed into high-rise with a central core design of enclosed lift lobbies without natural lighting. Electricity is required to provide illumination continuously for 24 h. A remote source solar lighting system using side-emitting fiber optic as illuminators is designed to reduce the emission of greenhouse gases for providing illumination to these lift lobbies. Experiment was carried out to test the performance of the daylighting system and proved that the remote source solar lighting system could displace an average of 3 h of electric lighting in a day and reduce 6.7 x 10(6) kg of carbon dioxide emission in a year. A study on the cost of the remote source solar lighting system was conducted and compared to the cost of the conventional lighting systems. Both the maintenance cost and environmental benefit that could be offered by the remote source solar lighting system were also studied in detail. Although the side-emitting technology of fiber optic is still primitive, further development can improve the emission efficiency and allow the remote source solar lighting system to operate more effectively. The potential of applying the remote source solar lighting system to conserve environment is promising. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:231 / 239
页数:9
相关论文
共 50 条
  • [1] Study on remote source solar lighting system application in high-rise residential buildings in Hong Kong
    Wong, Irene
    Yang, H. X.
    ENERGY AND BUILDINGS, 2013, 60 : 225 - 231
  • [2] BUILDING IMPLEMENTATION IN HIGH-RISE RESIDENTIAL BUILDINGS IN HONG KONG
    Lau, Wai Kin
    Ho, Daneiel Chi Wing
    OPEN HOUSE INTERNATIONAL, 2011, 36 (01) : 25 - 34
  • [3] Investigations of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    THERMAL SCIENCES 2000, 2000, : 505 - 510
  • [4] Investigation of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 491 - 496
  • [5] Energy performance of windows in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Sat, P
    ENERGY AND BUILDINGS, 2002, 34 (01) : 71 - 82
  • [6] Application of switchable glazing to high-rise residential buildings in Hong Kong
    Yik, F
    Bojic, M
    ENERGY AND BUILDINGS, 2006, 38 (05) : 463 - 471
  • [7] The airflow around and inside high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Burnett, J
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1331 - 1338
  • [8] Cooling energy evaluation for high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    ENERGY AND BUILDINGS, 2005, 37 (04) : 345 - 351
  • [9] Application of advanced glazing to high-rise residential buildings in Hong Kong
    Bojic, Milorad
    Yik, Francis
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 820 - 828
  • [10] Application of overhangs and side fins to high-rise residential buildings in Hong Kong
    Bojic, Milorad
    CIVIL ENGINEERING AND ENVIRONMENTAL SYSTEMS, 2006, 23 (04) : 271 - 285