Comparison of INNO-LiPA Genotyping Extra and Hybrid Capture 2 assays for detection of carcinogenic human papillomavirus genotypes

被引:19
|
作者
Barzon, Luisa [1 ,2 ]
Militello, Valentina [1 ,2 ]
Pagni, Silvana [1 ,2 ]
Palu, Giorgio [1 ,2 ]
机构
[1] Univ Padua, Dept Mol Med, Padua, Italy
[2] Padova Univ Hosp, Microbiol & Virol Unit, Padua, Italy
关键词
Human papillomavirus; Hybrid capture 2; Line probe assay; HPV genotyping; Cervical cancer screening; CERVICAL INTRAEPITHELIAL NEOPLASIA; RISK HUMAN-PAPILLOMAVIRUS; BLOT ASSAYS; CANCER; WOMEN; HYBRID-CAPTURE-2; PERFORMANCE; PRECANCER; OLDER;
D O I
10.1016/j.jcv.2012.07.013
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Accurate HPV detection and genotyping tests are useful for management of women with HPV infection and for monitoring HPV vaccine efficacy. Objectives: To evaluate the performance of the INNO-LiPA HPV Genotyping Extra assay (SPF10-LiPA) for the detection of carcinogenic HPV types in women referred for opportunistic cervical cancer screening by comparison with the Hybrid Capture 2 (HC2) assay. Study design: Cross-sectional analysis from baseline data of HC2 and SPF10-LiPA testing in cervical specimens collected from 1580 consecutive women and correlation with cervical cytology and histology data, when available. Results: The two assays showed a good agreement for detection of carcinogenic HPV types and reported the same prevalence of carcinogenic HPV infections in different age groups. Stratification of study subjects by cervical cytology interpretation and histology results demonstrated that the two tests gave very similar results in the different cytology interpretation groups and in CIN2 and CIN3 samples, while in <CIN2 samples the SPF10-LiPA assay provided a significantly lower number of carcinogenic HPV-positive results than the HC2 test. A comparative analysis of the two assay for individual HPV types showed that HC2 identified as positive between 73% and 100% of specimens with carcinogenic HPV types detected by SPF10-LiPA and, in particular, approximately 90% and 80% of HPV16- and HPV18-positive samples, respectively. Conclusions: A good agreement was observed between HC2 and SPF10-LiPA for carcinogenic HPV type detection, that supports further evaluation of the clinical performance of the new version of SPF10-LiPA in cervical cancer screening protocols. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [1] Comparison of Real-Time Multiplex Human Papillomavirus (HPV) PCR Assays with INNO-LiPA HPV Genotyping Extra Assay
    Else, Elizabeth A.
    Swoyer, Ryan
    Zhang, Yuhua
    Taddeo, Frank J.
    Bryan, Janine T.
    Lawson, John
    Van Hyfte, Inez
    Roberts, Christine C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) : 1907 - 1912
  • [2] Comparison of AdvanSure HPV GenoBlot Assay with INNO-LiPA HPV Genotyping for Human Papillomavirus Genotyping
    Chung, H.
    Lee, M.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 884 - 884
  • [3] Comparison of the AdvanSure HPV GenoBlot assay with the INNO-LiPA HPV Genotyping assay for human papillomavirus genotyping
    Chung, Hae-Sun
    Lee, Miae
    JOURNAL OF CLINICAL VIROLOGY, 2014, 60 (01) : 34 - 38
  • [4] Comparison of the INNO-LiPA and PapType Assays for Detection of Human Papillomavirus in Archival Vulva Dysplasia and/or Neoplasia Tissue Biopsy Specimens
    Tan, Sarah E.
    Garland, Suzanne M.
    Rumbold, Alice R.
    Tabrizi, Sepehr N.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (11) : 3980 - 3982
  • [5] Study Comparing Human Papillomavirus (HPV) Real-Time Multiplex PCR and Hybrid Capture II INNO-LiPA v2 HPV Genotyping PCR Assays
    Iftner, Thomas
    Germ, Liesje
    Swoyer, Ryan
    Kjaer, Susanne Kruger
    Breugelmans, J. Gabrielle
    Munk, Christian
    Stubenrauch, Frank
    Antonello, Joseph
    Bryan, Janine T.
    Taddeo, Frank J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (07) : 2106 - 2113
  • [6] Human Papillomavirus Genotyping Using Archival Vulval Dysplastic or Neoplastic Biopsy Tissues: Comparison between the INNO-LiPA and Linear Array Assays
    Tan, Sarah E.
    Garland, Suzanne M.
    Rumbold, Alice R.
    Tabrizi, Sepehr N.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) : 1458 - 1460
  • [7] Comparison of INNO-LiPA HPV Genotyping v2 with PCR product subcloning and sequencing for identification of genital human papillomavirus genotypes in African women
    Didelot-Rousseau, Marie-Noelle
    Courgnaud, Valerie
    Nagot, Nicolas
    Ouedraogo, Abdoulaye
    Konate, Issouf
    Mayaud, Philippe
    Weiss, Helen
    Van de Perre, Philippe
    Segondy, Michel
    JOURNAL OF VIROLOGICAL METHODS, 2006, 135 (02) : 181 - 185
  • [8] Direct comparison of mannose-binding lectin genotypes determined by ProGenotyper MBL and INNO-LIPA MBL2 genotyping assays
    Hester, JD
    Yu, J
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2004, 6 (04): : 413 - 413
  • [9] Performance of the New INNO-LiPA HPV Extra to Genotype Human Papillomavirus in Cervical Cell Specimens
    Galan-Sanchez, Fatima
    Hernandez-Menendez, Maite
    De los Rios Hernandez, Maria Angeles
    Rodriguez-Iglesias, Manuel
    ACTA CYTOLOGICA, 2011, 55 (04) : 341 - 343
  • [10] Comparison of HPV sign Genotyping Test with INNO-LiPA HPV Genotyping Extra assay on histologic and cytologic cervical specimens
    Barbieri, Daniela
    Nocera, Martina
    Gallinella, Giorgio
    Gentilomi, Giovanna Angela
    Plazzi, Marinella
    Costa, Sivano
    Santini, Donatella
    Venturoli, Simona
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (01) : 43 - 48