POTENTIOMETRIC FLUORIDE ANALYSIS WITH IMPROVED ANALYTICAL PERFORMANCE

被引:0
|
作者
Aarhaug, Thor A. [1 ]
Nagy, Kalman [1 ]
Smith, Kieran G. [1 ]
机构
[1] SINTEF Mat & Chem, NO-7465 Trondheim, Norway
来源
LIGHT METALS 2012 | 2012年
关键词
Fluorine analysis; Potentiometry; Acid Extraction; PH PF;
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Since the 1960s SINTEF has, in collaboration with the Nordic aluminium smelters, developed methods for sampling and analysis of fluoride. Unlike conventional potentiometric analysis, this methodology involves detection of fluoride in acidic media. At low pH, the electrode kinetics is improved, resulting in faster analysis. By masking of the fluoride leakage from the ion-selective electrode, the sensitivity of the method is improved. Standard addition methodology is applied for improved analytical performance. The acidic media makes it possible to perform a direct analysis of fluoride in biological samples. In this way, fluoride is extraced from the biological matrix by the acid. The high sensitivity requires low sample masses used and thus does not interfere with the fluoride detection at the ion-selective electrode. This is far more efficient than the conventional approach of ashing the sample at elevated temperatures. Acid extraction can also be applied to filter dust samples.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 50 条
  • [1] Development of a tubular fluoride potentiometric detector for flow analysis - Evaluation and analytical applications
    Rodrigo Santos, Joao
    Lapa, R. A. S.
    Lima, Jose L. F. C.
    ANALYTICA CHIMICA ACTA, 2007, 583 (02) : 429 - 436
  • [2] Improved performance of the potentiometric biosensor for the determination of creatinine
    Dallerup Rasmussen, Claus
    Andersen, Jens E. T.
    Zachau-Christiansen, Birgit
    ANALYTICAL LETTERS, 2007, 40 (01) : 39 - 52
  • [3] Flow injection analysis of fluoride in electroplating baths with potentiometric detection
    R. Pérez-Olmos
    M. B. Etxebarria
    J. L. F. C. Lima
    M. C. B. S. M. Montenegro
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 230 - 233
  • [4] On the control of interferences in the potentiometric fluoride analysis of table salt samples
    Esquivel-Pena, Vicente
    Munguia-Acevedo, Nadia M.
    Rodriguez de San Miguel, Eduardo
    Cesar Aguilar, Julio
    de Gyves, Josefina
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2016, 47 : 60 - 68
  • [5] Flow injection analysis of fluoride in electroplating baths with potentiometric detection
    Perez-Olmos, R
    Etxebarria, MB
    Lima, JLFC
    Montenegro, MCBSM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 230 - 233
  • [6] Potentiometric determination of fluoride in groundwaters
    Ion, I
    Ion, AC
    Barbu, L
    REVUE ROUMAINE DE CHIMIE, 2005, 50 (05) : 407 - 412
  • [7] POTENTIOMETRIC DETERMINATION OF FLUORIDE IN SOLIDS
    SAGER, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 298 (05): : 393 - 396
  • [8] Performance differences of two potentiometric fluoride determination methods in hard dental tissue
    Campus, Guglielmo
    Gaspa, Leonardo
    Pilo, Maria
    Scanu, Roberta
    Spano, Nadia
    Cagetti, Maria Grazia
    Sanna, Gavino
    FLUORIDE, 2007, 40 (02) : 111 - 115
  • [9] A COMPARISON OF 3 ANALYTICAL PROCEDURES FOR FLUORIDE ANALYSIS
    SUMMERLIN, DJ
    RETIEF, DH
    BRADLEY, EL
    HARRIS, BE
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 317 - 317
  • [10] Analysis of urine for fluoride; a comparison of analytical techniques
    Ketley, CE
    Lennon, MA
    Toumba, KJ
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 650 - 650