Johnson Noise Thermometry Measurement of the Boltzmann Constant With a 200 Ω Sense Resistor

被引:6
|
作者
Pollarolo, Alessio [1 ]
Jeong, Taehee [2 ]
Benz, Samuel P. [1 ]
Rogalla, Horst [1 ,3 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] Hitachi Global Storage Technol, San Jose, CA 95135 USA
[3] Univ Colorado, Dept Elect Engn, Boulder, CO 80302 USA
关键词
Boltzmann equation; Josephson junction; measurement units; noise measurement; standards; temperature; THERMAL AGITATION; CONDUCTORS; ACCURACY;
D O I
10.1109/TIM.2013.2239033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In 2010, the National Institute of Standards and Technology measured the Boltzmann constant k with an electronic technique that measured the Johnson noise of a 100 Omega resistor at the triple point of water and used a voltage waveform synthesized with a quantized voltage noise source (QVNS) as a reference. In this paper, we present measurements of k using a 200 Omega sense resistor and an appropriately modified QVNS circuit and waveform. Preliminary results show agreement with the previous value within the statistical uncertainty. An analysis is presented, where the largest source of uncertainty is identified, which is the frequency dependence in the constant term alpha(0) of the two-parameter fit.
引用
收藏
页码:1512 / 1517
页数:6
相关论文
共 50 条
  • [1] Improved electronic measurement of the Boltzmann constant by Johnson noise thermometry
    Qu, Jifeng
    Benz, Samuel P.
    Pollarolo, Alessio
    Rogalla, Horst
    Tew, Weston L.
    White, Rod
    Zhou, Kunli
    METROLOGIA, 2015, 52 (05) : S242 - S256
  • [2] Spectral model selection in the electronic measurement of the Boltzmann constant by Johnson noise thermometry
    Coakley, Kevin J.
    Qu, Jifeng
    METROLOGIA, 2017, 54 (02) : 204 - 217
  • [3] Measurement of the Boltzmann constant by Johnson noise thermometry using a superconducting integrated circuit
    Urano, C.
    Yamazawa, K.
    Kaneko, N-H
    METROLOGIA, 2017, 54 (06) : 847 - 855
  • [4] A Boltzmann constant determination based on Johnson noise thermometry
    Flowers-Jacobs, N. E.
    Pollarolo, A.
    Coakley, K. J.
    Fox, A. E.
    Rogalla, H.
    Tew, W. L.
    Benz, S. P.
    METROLOGIA, 2017, 54 (05) : 730 - 737
  • [5] An improved electronic determination of the Boltzmann constant by Johnson noise thermometry
    Qu, Jifeng
    Benz, Samuel P.
    Coakley, Kevin
    Rogalla, Horst
    Tew, Weston L.
    White, Rod
    Zhou, Kunli
    Zhou, Zhenyu
    METROLOGIA, 2017, 54 (04) : 549 - 558
  • [6] The NIST Johnson Noise Thermometry System for the Determination of the Boltzmann Constant
    Flowers-Jacobs, Nathan E.
    Pollarolo, Alessio
    Coakley, Kevin J.
    Weis, Adam C.
    Fox, Anna E.
    Rogalla, Horst
    Tew, Weston L.
    Benz, Samuel P.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2017, 122
  • [7] Boltzmann Constant Measurements Using QVNS-Based Johnson Noise Thermometry at NMIJ, AIST
    K. Yamazawa
    C. Urano
    T. Yamada
    T. Horie
    S. Yoshida
    H. Yamamori
    N. Kaneko
    Y. Fukuyama
    M. Maruyama
    A. Domae
    J. Tamba
    S. Kiryu
    International Journal of Thermophysics, 2014, 35 : 985 - 998
  • [8] Boltzmann Constant Measurements Using QVNS-Based Johnson Noise Thermometry at NMIJ, AIST
    Yamazawa, K.
    Urano, C.
    Yamada, T.
    Horie, T.
    Yoshida, S.
    Yamamori, H.
    Kaneko, N.
    Fukuyama, Y.
    Maruyama, M.
    Domae, A.
    Tamba, J.
    Kiryu, S.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (6-7) : 985 - 998
  • [9] Electronic measurement of the Boltzmann constant with a quantum-voltage-calibrated Johnson noise thermometer
    Benz, Samuel
    White, D. Rod
    Qu, JiFeng
    Rogalla, Horst
    Tew, Weston
    COMPTES RENDUS PHYSIQUE, 2009, 10 (09) : 849 - 858
  • [10] Johnson noise thermometry for space reactor temperature measurement
    Holcomb, DE
    Kisner, RA
    Roberts, MJ
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM-STAIF 2004, 2004, 699 : 567 - 573