Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

被引:0
|
作者
Gadhi, M. A. [1 ]
Buzdar, S. A. [2 ]
Afzal, M. [2 ]
Fatmi, Sh. [1 ]
Akhtar, M. S. [1 ]
Nizamani, A. H. [3 ]
机构
[1] Bahawalpur Inst Nucl Med & Oncol BINO Bahawalpur, Bahawalpur, Pakistan
[2] Islamia Univ Bahawalpur, Dept Phys, Bahawalpur, Pakistan
[3] Univ Sind, Dept Phys, Hyderabad, Andhra Pradesh, India
来源
关键词
Brachytherapy; calibration; ionization chamber; HDR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source Ir-192. This work has been carried out to calibrate the high dose rate (HDR) Ir-192 sources. Materials and Methods: An interpolation procedure, using calibrations above 1.25 MeV (Co-60), and below 135 kV X-rays (61.1 keV), the exposure-weighted average energy 397 keV of Ir-192 is employed. Using Farmer ionization chamber HDR Ir-192 source has been calibrated by free in-air measurement technique and then the calibrated source has been used to calibrate well-type ionization chamber. Results: Difference between in-air measurement and that of manufacturer's remained within +/- 3%, and the difference between in-air measurement and well-type chamber remained within +/- 1%. Comparison between well-type measurements and manufacturer values shows differences less than +/- 2%. All these differences are within the acceptable tolerance limits. Conclusion: The method presented shows good degree of accuracy so that the traceability of calibration is assured. Installation of a new brachytherapy source needs to be calibrated by in-air measurement technique and then this calibrated source should be used for well chamber calibration. Brachytherapy community is suggested to calibrate their sources with this method.
引用
收藏
页码:189 / 193
页数:5
相关论文
共 50 条
  • [1] Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source
    Ravikumar, Barlanka
    Lakshminarayana, S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 27 - 31
  • [2] Comparison of calibration procedures of iridium-192 sources used in high dose rate brachytherapy system
    Kumar, A
    Singh, S
    Agrawal, S
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2003, 41 (04) : 253 - 257
  • [3] Calibration of pre-cut iridium-192 wires for low dose rate interstitial brachytherapy using a Farmer-type ionization chamber
    Vollans, SE
    Wilkinson, JM
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866): : 201 - 205
  • [4] Four year clinical statistics of iridium-192 high dose rate brachytherapy
    Shigehara, K
    Mizokami, A
    Komatsu, K
    Koshida, K
    Namiki, M
    INTERNATIONAL JOURNAL OF UROLOGY, 2006, 13 (02) : 116 - 121
  • [5] Anisotropy of an (192)iridium high dose rate source measured with a miniature ionization chamber
    Mishra, V
    Waterman, FM
    Suntharalingam, N
    MEDICAL PHYSICS, 1997, 24 (05) : 751 - 755
  • [6] Comments on the calibration of pre-cut iridium-192 wires for low dose rate interstitial brachytherapy using a Farmer-type ionization chamber
    Plane, JH
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (879): : 291 - 292
  • [7] Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source
    Medich, David C.
    Munro, John J., III
    MEDICAL PHYSICS, 2007, 34 (06) : 1999 - 2006
  • [8] Comments on the calibration of pre-cut iridium-192 wires for low dose rate interstitial brachytherapy using a Farmer-type ionization chamber -: Reply
    Wilkinson, JM
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (879): : 292 - 293
  • [9] Clinical Results of Iridium-192 High Dose Rate Brachytherapy with External Beam Radiotherapy
    Nohara, Takahiro
    Mizokami, Atsushi
    Kumano, Tomoyasu
    Shigehara, Kazuyoshi
    Konaka, Hiroyuki
    Yoshifumi, Kadono
    Yasuhide, Kitagawa
    Izumi, Kouji
    Narimoto, Kazutaka
    Namiki, Mikio
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2010, 40 (07) : 677 - 683
  • [10] New fluoroscopy system for monitoring source position in brachytherapy by a high-dose-rate iridium-192 remote afterloader
    Ishii, M
    Fukuda, H
    Miyamoto, T
    Hirokawa, K
    Nagano, K
    Fouriner-Bidoz, N
    RADIOLOGY, 1998, 209P : 158 - 158