Ex vivo surface and mechanical properties of coated orthodontic archwires

被引:79
|
作者
Elayyan, Firas
Silikas, Nick [2 ]
Bearn, David [1 ]
机构
[1] Univ Dundee, Sch Dent, Dundee DD1 4HN, Scotland
[2] Univ Manchester, Sch Dent, Manchester M13 9PL, Lancs, England
关键词
D O I
10.1093/ejo/cjn057
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the mechanical and physical properties of retrieved coated nickel-titanium (NiTi) archwires compared with unused samples. Ultraesthetic (TM) 0.016 inch coated archwires (G & Wire Company) were investigated. Ten as-received wires were subjected to a three-point bending test using conventional and self-ligating bracket systems. Surface roughness of the coating was measured with a contact stylus profilometer. Optical and scanning electron microscopes were used to assess surface topography. Ten archwires were used in vivo for a period of between 4 and 6 weeks. Retrieved archwires were subjected to the same tests. The percentage of the remaining coating was calculated using digital photography. Coated archwires were used in vivo for a mean period of 33 days. Differences between the mean values of the as-received and retrieved archwires were determined using t-tests. In the three-point bending test, with conventional elastomeric ligation, retrieved wires produced a lower unloading force (P < 0.001). Both retrieved and as-received coated archwires produced zero values of unloading force when deflected for 4 mm. When tested using a self-ligating bracket system, retrieved and as-received coated archwires produced the same amount of force (P > 0.05). With surface profilometry, all measured roughness parameters (except R-sm) had greater surface roughness for the retrieved coated archwires (P < 0.05). Under microscopy, retrieved coated archwires showed discolouration, ditching, and delamination. Only 75 per cent of the coating was present in retrieved coated archwires. Retrieved coated archwires produced lower unloading force values than as-received coated archwires with conventional ligation. Surface roughness of coated archwires increased after use. Coated archwires have a low aesthetic value, with 25 per cent of the coating lost within 33 days in vivo.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [1] Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires
    da Silva, Dayanne Lopes
    Mattos, Claudia Trindade
    Sant' Anna, Eduardo Franzotti
    de Oliveira Ruellas, Antonio Carlos
    Elias, Carlos Nelson
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (04) : S85 - S91
  • [2] The effect of autoclave cycles on the mechanical properties and surface roughness of NiTi archwires: ex-vivo study
    El Shahawi, Amal Magdi
    Aboalnaga, Amira Ahmed
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic brackets
    Elayyan, Firas
    Silikas, Nick
    Bearn, David
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (02) : 213 - 217
  • [4] Coating stability and surface characteristics of esthetic orthodontic coated archwires
    da Silva, Dayanne Lopes
    Mattos, Claudia Trindade
    Simao, Renata Autoun
    de Oliveira Ruellas, Antonio Carlos
    ANGLE ORTHODONTIST, 2013, 83 (06) : 994 - 1001
  • [5] Infrared spectroscopy, nano-mechanical properties, and scratch resistance of esthetic orthodontic coated archwires
    da Silva, Dayanne Lopes
    Santos, Emanuel, Jr.
    Camargo, Sergio de Souza, Jr.
    de Oliveira Ruellas, Antonio Carlos
    ANGLE ORTHODONTIST, 2015, 85 (05) : 777 - 783
  • [6] Influence of the Chemical Composition on the Mechanical Properties of Orthodontic Archwires
    Pop, Silvia-Izabella
    Dudescu, Mircea
    Bratu, Dana Cristina
    Pop, Radu-Vasile
    Petrisor, Marius
    Pacurar, Mariana
    REVISTA DE CHIMIE, 2013, 64 (07): : 771 - 775
  • [7] Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires
    Zegan, Georgeta
    Sodor, Alina
    Munteanu, C.
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2012, 53 (04): : 935 - 939
  • [8] Surface Ultrastructure and Mechanical Properties of Three Different White-Coated NiTi Archwires
    Ryu, Seong-Hee
    Lim, Byung-Suh
    Kwak, Eun Joo
    Lee, Gi-Ja
    Choi, Samjin
    Park, Ki-Ho
    SCANNING, 2015, 37 (06) : 414 - 421
  • [9] Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
    Hobbelink, Marieke G.
    He, Yan
    Xu, Jia
    Xie, Huixu
    Stoll, Richard
    Ye, Qingsong
    PROGRESS IN ORTHODONTICS, 2015, 16
  • [10] Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
    Marieke G. Hobbelink
    Yan He
    Jia Xu
    Huixu Xie
    Richard Stoll
    Qingsong Ye
    Progress in Orthodontics, 16