Low angle X-ray scatter for explosives detection: A geometry optimization

被引:34
|
作者
Luggar, RD
Horrocks, JA
Speller, RD
Lacey, RJ
机构
[1] UCL, DEPT MED PHYS, LONDON WC1E 6JA, ENGLAND
[2] PSDB, ST ALBANS AL4 9HQ, HERTS, ENGLAND
关键词
D O I
10.1016/S0969-8043(96)00212-6
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A geometry has been established for a low angle X-ray scatter (LAXS) system for the detection of sheet explosive in passenger baggage. The energy dispersive diffraction profiles of two typical explosives, PE4 and Semtex, have been investigated under a wide range of geometric conditions. A scatter angle of 5 degrees and a slit collimation arrangement with an angular resolution of 20% has been found to satisfy the required criteria of well-defined, high intensity diffraction profiles at the sufficiently high energies necessary to penetrate baggage items. An investigation of typical benign suitcase contents under the optimal geometry show in general broad low-order diffraction profiles in contrast to the highly characteristic diffraction from the explosives. Real time measurement of explosives show that characteristic diffraction profiles can be measured in times as short as 0.1 s although a large statistical uncertainty results. Copyright (C) 1997 Elsevier Science Ltd
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [1] Low angle X-ray scatter for explosives detection: A geometry optimization
    Clinical Physics Department, St. Bartholomew's Hospital, London EC1A 7BE, United Kingdom
    不详
    不详
    APPL. RADIAT. ISOT., 2 (215-224):
  • [2] X-ray scatter tomography for explosives detection
    Harding, G
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 869 - 881
  • [3] Detection of explosives by coherent X-ray scatter signature
    Wei Cun-Feng
    Yu Zhong-Qiang
    Yan Yong-Lian
    Zhou Hua-Shi
    Gao Shu-Qi
    Kong Wei
    Xue De-Sheng
    Wei Long
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (01): : 104 - 107
  • [4] AUTOMATIC SCANNING INSTRUMENT FOR X-RAY LOW-ANGLE SCATTER
    BECK, BL
    GUNN, EL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (08): : 662 - 664
  • [5] LOW ANGLE X-RAY SCATTERING .2. LOW ANGLE X-RAY CAMERAS
    ULICKY, L
    CHEMICKE ZVESTI, 1967, 21 (07): : 531 - &
  • [6] Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography
    Guo Jing
    Feng Peng
    Deng Luzhen
    Luo Yan
    He Peng
    Wei Biao
    ACTA OPTICA SINICA, 2020, 40 (01)
  • [7] Beagle vision - X-ray scanning for explosives detection
    不详
    MATERIALS WORLD, 2005, 13 (02) : 24 - 26
  • [8] The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT
    Bootsma, G. J.
    Verhaegen, F.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2011, 38 (02) : 897 - 914
  • [9] A METHOD FOR SMOOTHING X-RAY SMALL ANGLE SCATTER CURVES OF PARTICLES
    OELSCHLA.H
    ACTA PHYSICA AUSTRIACA, 1969, 30 (04): : 323 - &
  • [10] A CdZnTe array for the detection of explosives in baggage by energy-dispersive X-ray diffraction signatures at multiple scatter angles
    Malden, CH
    Speller, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (1-2): : 408 - 415