In vitro evaluation of wire integrity and ability to reprocess single-use sphincterotomes

被引:22
|
作者
Kozarek, RA
Sumida, SE
Raltz, SL
Merriam, LD
Irizarry, DC
机构
[1] VIRGINIA MASON MED CTR,SECT CLIN LAB,SEATTLE,WA 98111
[2] VIRGINIA MASON MED CTR,SECT BIOMED ENGN,SEATTLE,WA 98111
关键词
D O I
10.1016/S0016-5107(97)70232-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Sphincterotomes are currently marketed as one-time-use items and constitute considerable cumulative expense in a busy endoscopy unit. It is uncertain whether these accessories can be safely reprocessed without loss of form and function. Methods: We studied disposable sphincterotomes (five 5F, five 6F) in vitro as to their durability, electrical integrity, and ability to be adequately cleaned both manually and with ethylene oxide after contamination with 10(5) to 10(6) Mycobacterium chelonei. Results: Seven of the 10 sphincterotomes withstood the rigors of reuse; three 6F sphincterotomes developed wire fracture between four and eight uses. Electrical integrity, as measured by an electrosurgical analyzer, remained intact up to time of breakage in ail sphincterotomes. Manual cleaning followed by glutaraldehyde soak resulted in residual mycobacterial colonies in five 6F sphincterotomes and a single 5F sphincterotome. No instrument had residual organisms cultured following manual cleaning and ethylene oxide sterilization. Conclusions: The authors conclude that one-time-use sphincterotomes have the potential for safe reuse.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [1] In vitro evaluation of wire integrity and manual processing of single-use sphincterotomes.
    Kozarek, R
    Sumida, S
    Raltz, S
    Merriam, L
    Irizarry, D
    GASTROINTESTINAL ENDOSCOPY, 1996, 43 (04) : 103 - 103
  • [2] Single-use Trocar Is it Possible to Reprocess it After the First Use?
    dos Santos, Vania Sue Ellen
    Zilberstein, Bruno
    Possari, Joao Francisco
    dos Santos, Manoel A. A.
    Quintanilha, Alina G.
    Ribeiro, Ulysses, Jr.
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2008, 18 (05): : 464 - 468
  • [3] In vitro evaluation of integrity and sterilization of single-use argon beam plasma coagulation probes
    Roach, SK
    Kozarek, RA
    Raltz, SL
    Sumida, SE
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1999, 94 (01): : 139 - 143
  • [4] Single-Use System Integrity
    Hogreve, Marc
    BIOPHARM INTERNATIONAL, 2020, 33 (01) : 26 - 27
  • [5] Connector Integrity in Single-Use Biomanufacturing Systems
    Mirasol, Feliza
    BIOPHARM INTERNATIONAL, 2017, 30 (11) : 24 - 27
  • [6] A q&a single-use system integrity
    Hogreve, Marc
    Pharmaceutical Technology, 2020, 44 (01)
  • [7] Single-Use vs Reusable Therapeutic Gastroscope Suctioning Ability
    Goodman, Adam J.
    Cool, Christina
    Hoffman, David
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S728 - S729
  • [8] EVALUATION OF SINGLE-USE PACKS OF HOSPITAL DISINFECTANTS
    FARRAND, RJ
    WILLIAMS, A
    LANCET, 1973, 1 (7803): : 591 - 593
  • [9] Evaluation of a Novel Single-Use Flexible Ureteroscope
    Dale, Joanne
    Kaplan, Adam G.
    Radvak, Daniela
    Shin, Richard
    Ackerman, Anika
    Chen, Tony
    Scales, Charles D., Jr.
    Ferrandino, Michael N.
    Simmons, Walter Neal
    Preminger, Glenn M.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2021, 35 (06) : 903 - 907
  • [10] Environmental evaluation of single-use and reusable cups
    Garrido, Nuria
    Alvarez del Castillo, M. Dolors
    INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2007, 12 (04): : 252 - 256