Droplet Volume Variability and Impact on Digital PCR Copy Number Concentration Measurements

被引:33
|
作者
Emslie, Kerry R. [1 ]
McLaughlin, Jacob L. H. [1 ]
Griffiths, Kate [1 ]
Forbes-Smith, Michael [1 ]
Pinheiro, Leonardo B. [1 ]
Burke, Daniel G. [1 ]
机构
[1] Natl Measurement Inst, Lindfield, NSW 2070, Australia
关键词
ACCURATE QUANTIFICATION; DNA; BIAS;
D O I
10.1021/acs.analchem.8b05828
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Digital polymerase chain reaction (dPCR) is increasingly being adopted by reference material producers and metrology institutes for value assignment, and for homogeneity and stability studies of nucleic acid reference materials. A reference method procedure should fulfill several requirements, and the uncertainty and biases should be completely understood. A bias in target concentration when inaccurate droplet volume is used in the droplet dPCR measurement equation has previously been documented. In this study, we characterize both intrawell and interwell droplet volume variability using optical microscopy and determine the impact of these two sources of variability on target concentration estimates. A small optical distortion across the image was measured which, without correction, biased droplet volume measurements. Longitudinal monitoring of interwell droplet volume over 39 weeks using several lots of Mastermix demonstrated a mean droplet volume of 0.786 nL and intermediate precision of 1.7%. The frequency distribution of intrawell droplet volumes varied. Some wells displayed a skewed distribution which resulted in a small bias in estimated target concentration for a simulated dPCR with target concentrations of between 62 and 8000 copies mu L-1. The size and direction of this bias was influenced by the distribution pattern of the droplet volumes within the well. The proportion of Mastermix in dPCR mix affected droplet volume. A pipetting error of 10% during mixing of the premix and Mastermix resulted in a 2.6% change in droplet volume and, consequently, a bias in concentration measurements highlighting the advantages of gravimetric preparation of dPCR mixes for high accuracy measurements.
引用
收藏
页码:4124 / 4131
页数:8
相关论文
共 50 条
  • [1] Copy number variability of expression plasmids determined by cell sorting and Droplet Digital PCR
    Michael Jahn
    Carsten Vorpahl
    Thomas Hübschmann
    Hauke Harms
    Susann Müller
    Microbial Cell Factories, 15
  • [2] Copy number variability of expression plasmids determined by cell sorting and Droplet Digital PCR
    Jahn, Michael
    Vorpahl, Carsten
    Huebschmann, Thomas
    Harms, Hauke
    Mueller, Susann
    MICROBIAL CELL FACTORIES, 2016, 15
  • [3] DNA copy number concentration measured by digital and droplet digital quantitative PCR using certified reference materials
    Corbisier, Philippe
    Pinheiro, Leonardo
    Mazoua, Stephane
    Kortekaas, Anne-Marie
    Chung, Pui Yan Jenny
    Gerganova, Tsvetelina
    Roebben, Gert
    Emons, Hendrik
    Emslie, Kerry
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (07) : 1831 - 1840
  • [4] DNA copy number concentration measured by digital and droplet digital quantitative PCR using certified reference materials
    Philippe Corbisier
    Leonardo Pinheiro
    Stéphane Mazoua
    Anne-Marie Kortekaas
    Pui Yan Jenny Chung
    Tsvetelina Gerganova
    Gert Roebben
    Hendrik Emons
    Kerry Emslie
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1831 - 1840
  • [5] Measurement of Transgene Copy Number in Plants Using Droplet Digital PCR
    Cai, Yao-Min
    Dudley, Quentin M.
    Patron, Nicola J.
    BIO-PROTOCOL, 2021, 11 (13):
  • [6] Copy number and zygosity determination of transgenic rapeseed by droplet digital PCR
    Yuhua Wu
    Jun Li
    Xiaying Li
    Jingang Liang
    Yunjing Li
    Xinhua Zeng
    Gang Wu
    Oil Crop Science, 2017, 2 (02) : 84 - 94
  • [7] Quantification of Plasmid Copy Number with Single Colour Droplet Digital PCR
    Plotka, Magdalena
    Wozniak, Mateusz
    Kaczorowski, Tadeusz
    PLOS ONE, 2017, 12 (01):
  • [8] Measurement of Transgenes Copy Number in Wheat Plants Using Droplet Digital PCR
    Liu, Peng
    Liu, Shuang
    Lei, Jiajia
    Chen, Jianping
    Yang, Jian
    BIO-PROTOCOL, 2022, 12 (23):
  • [9] Application of droplet digital PCR to determine copy number of endogenous genes and transgenes in sugarcane
    Yue Sun
    Priya Aiyar Joyce
    Plant Cell Reports, 2017, 36 : 1775 - 1783
  • [10] An Efficient Approach to Check Accuracy of Viral Copy Number Assay in Droplet Digital PCR
    Wu, Raymond
    Luh, Frank
    Masten, Jeff
    Yen, Yun
    MOLECULAR THERAPY, 2023, 31 (04) : 716 - 716