Effects of posterior pelvic tilt on anterior instability in total hip arthroplasty: A parametric experimental modeling evaluation

被引:23
|
作者
Sato, Taishi [1 ]
Nakashima, Yasuharu [1 ]
Matsushita, Akinobu [1 ]
Fujii, Masanori [1 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
关键词
Total hip arthroplasty; Pelvic tilt; Anterior dislocation; Offset; Range of motion; NORMAL AXIAL ALIGNMENT; ANKYLOSING-SPONDYLITIS; RADIOLOGICAL ANALYSIS; HEAD SIZE; MOTION; RANGE; DISLOCATIONS; ROTATION; POSITION; SYSTEM;
D O I
10.1016/j.clinbiomech.2012.12.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Anterior dislocation is one of the concerns of patients with posterior pelvic tilt undergoing total hip arthroplasty. This study aimed to evaluate the magnitude of posterior pelvic tilt constituting a risk for anterior dislocation by measuring the range of motion until impingement and dislocation under various pelvic tilt. Methods: Using a jig mounted prosthetic hip model, the ranges of external rotation at extension and internal rotation at flexion until reaching dislocation were tested. The site of impingement prior to dislocation was also recorded. Posterior pelvic tilt and the cup version were changed with 10 degrees increments from 0 degrees to 40 degrees and from 10 degrees retroversion to 30 degrees anteversion, respectively. Effects of increasing femoral offset were also tested. We defined a required range of motion as having 30 degrees external rotation at extension and 40 degrees internal rotation at 90 degrees flexion. Findings: External rotation decreased in a posterior pelvic tilt-dependent manner. In the case with more than 20 degrees posterior pelvic tilt, available external rotation extended beyond required range with the cup anteversion of 20 degrees. Decreasing cup anteversion improved external rotation, however, internal rotation decreased simultaneously. In the case with posterior pelvic tilt more than 20 degrees, only cup anteversion with 0 degrees or 10 degrees satisfied the required range of motion. A + 4 mm horizontal offset improved external rotation by 10 degrees with delaying bony impingement. Interpretation: More than 20 degrees of posterior pelvic tilt may cause anterior instability and diminish the optimal range of cup version. Increasing the femoral offset improved external rotation without reducing internal rotation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:178 / 181
页数:4
相关论文
共 50 条
  • [1] Is Dislocation Risk due to Posterior Pelvic Tilt Reduced With Direct Anterior Approach Total Hip Arthroplasty?
    Fritz, Justin K.
    Waddell, Bradford S.
    Kitziger, Kurt J.
    Peters, Paul C., Jr.
    Gladnick, Brian P.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (11): : 3692 - 3696
  • [2] Is the Rate of Change in Posterior Pelvic Tilt After Total Hip Arthroplasty Constant?
    Kagawa, Katsura
    Nakamura, Takuya
    Sasagawa, Takeshi
    ARTHROPLASTY TODAY, 2022, 15 : 147 - 152
  • [3] Quantification of Pelvic Tilt in Total Hip Arthroplasty
    Zhu, Jinjun
    Wan, Zhinian
    Dorr, Lawrence D.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 571 - 575
  • [4] Axial pelvic tilt in direct anterior Total hip Arthroplasty using a traction table
    A. Aichmair
    M. Dominkus
    J. G. Hofstaetter
    BMC Musculoskeletal Disorders, 21
  • [5] Axial pelvic tilt in direct anterior Total hip Arthroplasty using a traction table
    Aichmair, A.
    Dominkus, M.
    Hofstaetter, J. G.
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [6] Pelvic Tilt Is Minimally Changed by Total Hip Arthroplasty
    Murphy, William S.
    Klingenstein, Greg
    Murphy, Stephen B.
    Zheng, Guoyan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 417 - 421
  • [7] Changes in pelvic tilt following total hip arthroplasty
    Ishida, Takashi
    Inaba, Yutaka
    Kobayashi, Naomi
    Iwamoto, Naoyuki
    Yukizawa, Yohei
    Choe, Hyonmin
    Saito, Tomoyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (06) : 682 - 688
  • [8] Pelvic tilt after total hip arthroplasty in patients with osteoarthritis of the hip
    Tateiwa, Toshiyuki
    Endo, Kenji
    Matsuoka, Yuji
    Ishida, Tsunehito
    Shishido, Takaaki
    Yamamoto, Kengo
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (02)
  • [9] Preoperative Pelvic Tilt Analysis Reduces Fluoroscopy Time in Direct Anterior Total Hip Arthroplasty
    Weeks, Colleen A.
    Preston, Stephen
    Howard, James L.
    Vasarhelyi, Edward M.
    Matz, Jacob
    Lanting, Brent A.
    ORTHOPEDICS, 2016, 39 (05) : E962 - E966
  • [10] Statistical Shape Modeling to Determine the Anterior Pelvic Plane for Total Hip Arthroplasty
    Guezou-Philippe, Aziliz
    Dardenne, Guillaume
    Salhi, Asma
    Burdin, Valerie
    Lefevre, Christian
    Stindel, Eric
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1364 - 1367