Distortional failure and DSM design of cold-formed steel lipped channel beams under elevated temperatures

被引:36
|
作者
Landesmann, Alexandre [1 ]
Camotim, Dinar [2 ]
机构
[1] Univ Fed Rio de Janeiro, COPPE, Civil Engn Program, BR-21941 Rio De Janeiro, Brazil
[2] Univ Lisbon, Inst Super Tecn, DECivil, ICIST,CEris, Lisbon, Portugal
关键词
Cold-formed steel beams; Lipped channels; Elevated temperatures; Distortional buckling/failure; Numerical (SFE) analysis; Direct Strength Method (DSM) design; DIRECT STRENGTH METHOD; STRUCTURAL BEHAVIOR; IMPERFECTION SENSITIVITY; MECHANICAL-PROPERTIES; BUCKLING RESISTANCE; WALL SYSTEMS; FIRE; COLUMNS; SECTIONS; UNIFORM;
D O I
10.1016/j.tws.2015.06.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this paper is to report an ongoing shell finite element investigation on the distortional post-buckling behaviour, ultimate strength and DSM design of cold-formed steel single-span lipped channel beams under elevated temperatures due to fire conditions. The beam ultimate strengths are computed by means of a steady-state loading strategy that consists of applying an increasing major-axis uniform bending moment to a beam under a uniform and constant (elevated) temperature distribution, until failure is reached. The steel constitutive law at elevated temperatures is simulated by means of the stress-strain-temperature models prescribed in EC3-1.2 for cold-formed steel. The materially and geometrically non-linear response of the cold-formed lipped channel beams is determined through ANSYS shell finite element analyses that incorporate critical-mode (distortional) initial geometrical imperfections. Finally, since there are no specific rules to predict the bending strength of cold-formed steel beams failing in distortional modes at elevated temperatures, the above failure moments and temperatures are used to establish preliminary guidelines for the design of cold-formed steel lipped channel beams under fire conditions. The approach followed is based on the Direct Strength Method (DSM) and has been already employed by other researchers - the currently available design/strength equations/curves, developed for ambient temperature, are modified to account for the appropriate Young's modulus and yield stress reductions due to the temperature increase. The results presented in the paper provide solid numerical evidence that the currently codified DSM distortional strength curve is not appropriate to predict beam failure moments at elevated temperatures. This is because it either (i) does not account for the material non-linearity due to the elevated temperature (low-to-moderate slenderness range) or (ii) is already inadequate to predict room temperature failure moments (unsafe estimates obtained in the high slenderness range). (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:75 / 93
页数:19
相关论文
共 50 条
  • [1] DSM Design of Cold-Formed Steel Columns Failing in Distortional Modes at Elevated Temperatures
    Landesmann, Alexandre
    Camotim, Dinar
    Silva, Fernanda C. M.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2019, 19 (03) : 1023 - 1041
  • [2] DSM Design of Cold-Formed Steel Columns Failing in Distortional Modes at Elevated Temperatures
    Alexandre Landesmann
    Dinar Camotim
    Fernanda C. M. Silva
    International Journal of Steel Structures, 2019, 19 : 1023 - 1041
  • [3] Local/distortional mode interaction in cold-formed steel lipped channel beams
    Dinis, P. Borges
    Camotim, Dinar
    THIN-WALLED STRUCTURES, 2010, 48 (10-11) : 771 - 785
  • [4] Cold-formed steel lipped channel columns at elevated temperatures
    Chen, Ju
    Young, Ben
    ENGINEERING STRUCTURES, 2007, 29 (10) : 2445 - 2456
  • [5] Distortional failure of cold-formed steel beams under uniform bending: Behaviour, strength and DSM design
    Martins, Andre Dias
    Landesmann, Alexandre
    Camotim, Dinar
    Dinis, Pedro Borges
    THIN-WALLED STRUCTURES, 2017, 118 : 196 - 213
  • [6] CFS lipped channel beams buckling in distortional modes at elevated temperatures: Behaviour, failure and DSM design
    das Neves, Natan Sian
    Landesmann, Alexandre
    Camotim, Dinar
    THIN-WALLED STRUCTURES, 2024, 195
  • [7] Local-distortional buckling interaction on cold-formed steel lipped channel beams
    Anbarasu, M.
    THIN-WALLED STRUCTURES, 2016, 98 : 351 - 359
  • [8] On the distortional post-buckling behaviour of cold-formed lipped channel steel beams
    Prola, LC
    Camotim, D
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 331 - 339
  • [9] Distortional Failure and DSM Design of Cold-Formed Steel S-Shaped Beams Under Uniform Bending
    Barichello, Carolina
    Landesmann, Alexandre
    Camotim, Dinar
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2017, 14 (12): : 2123 - 2140
  • [10] Cold-Formed Steel Lipped Channel Columns Influenced by Local-Distortional Interaction: Strength and DSM Design
    Young, Ben
    Silvestre, Nuno
    Camotim, Dinar
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (06) : 1059 - 1074