Usefulness of Xpert MTB/RIF Ultra to Rapidly Diagnose Sputum Smear-Negative Pulmonary Tuberculosis Using Bronchial Washing Fluid

被引:8
|
作者
Chien, Jung-Yien [1 ]
Lin, Ching-Kai [1 ]
Yu, Chong-Jen [1 ]
Hsueh, Po-Ren [2 ]
机构
[1] Natl Taiwan Univ, Coll Med, Dept Internal Med, Natl Taiwan Univ Hosp, Taipei, Taiwan
[2] Natl Taiwan Univ, Coll Med, Dept Lab Med, Natl Taiwan Univ Hosp, Taipei, Taiwan
关键词
pulmonary tuberculosis; Xpert MTB; RIF Ultra; COBAS TaqMan; MTB; bronchoscopy; MYCOBACTERIUM-TUBERCULOSIS; BRONCHOALVEOLAR LAVAGE; BRONCHOSCOPY; RESISTANCE; ACCURACY; CULTURE; RELAPSE; TIME;
D O I
10.3389/fmicb.2020.588963
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
This study evaluated the performance of the Xpert MTB/RIF Ultra assay (Xpert Ultra) to detect smear-negative pulmonary tuberculosis (PTB). Xpert Ultra assay was prospectively performed using bronchial washing fluid (BWF) in comparison to COBAS TaqMan MTB (COBAS) assay and mycobacterial culture. Of the 165 enrolled participants, 27 (16.4%) had PTB based on composite reference standard and 16 (9.7%) had culture-confirmed PTB. By the composite reference standard of PTB, the sensitivity of Xpert Ultra (63.0, 95% confidence interval, CI, 42.4-80.6%) was higher than the COBAS assay (25.9%,P= 0.006), BWF-culture (33.3%,P= 0.029) and sputum-culture (37.0%,P= 0.057). Meanwhile, the specificity of Xpert Ultra was 99.3% which was slightly lower than the 100.0% specificity of the COBAS assay (P= 1.000) and cultures (P= 1.000). Against the reference standard of culture-confirmed PTB, Xpert Ultra also had a higher sensitivity (62.5, 95% CI, 35.4-84.8%) than the COBAS assay (31.3%,P= 0.077) and was similar to BWF-culture (56.3%,P= 0.719) and sputum-culture (62.5%,P= 1.000). However, one subject with previously treated old PTB had a false-positive result on the Xpert Ultra assay. This prospective study showed Xpert Ultra assay using BWF had better sensitivity than COBAS assay and mycobacterial cultures but could represent a false positive in patients with inactive old PTB.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Xpert MTB/RIF in Sputum Smear-Negative Pulmonary Tuberculosis
    Rasheed, Waqas
    Rao, Nisar Ahmed
    Adel, Hatem
    Baig, Mirza Saifullah
    Adil, Syed Omair
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (08)
  • [2] Xpert Mtb/rif In Diagnosis Of Smear-Negative Pulmonary Tuberculosis
    Kawkitinarong, K.
    Avihingsanon, A.
    Ubolyam, S.
    Ruxrungtham, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [3] The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis
    Yao, Lan
    Chen, Shanhao
    Sha, Wei
    Gu, Ye
    BMC INFECTIOUS DISEASES, 2023, 23 (01)
  • [4] The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis
    Lan Yao
    Shanhao Chen
    Wei Sha
    Ye Gu
    BMC Infectious Diseases, 23
  • [5] Diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate specimens for microbiological confirmation of pulmonary tuberculosis in patients with negative smear and Xpert MTB/RIF Ultra results in sputum
    Chesov, Dumitru
    Ciobanu, Nelly
    Polevoi, Valentina
    Chesov, Elena
    Codreanu, Alexandru
    Lange, Christoph
    Crudu, Valeriu
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [6] PREDICTIVE ACCURACY AND CLINICAL IMPACT OF XPERT MTB/RIF FOR THE DIAGNOSIS OF SPUTUM SMEAR-NEGATIVE PULMONARY TUBERCULOSIS USING BRONCHOALVEOLAR LAVAGE FLUID
    Ho, W.
    Connell, D. W.
    Singanayagam, A.
    Singanayagam, A.
    Donaldson, H.
    Kon, O. M.
    THORAX, 2015, 70 : A26 - A26
  • [7] Rapid detection of Mycobacterium tuberculosis and rifampicin resistance in extrapulmonary tuberculosis and sputum smear-negative pulmonary suspects using Xpert MTB/RIF
    Ullah, Irfan
    Javaid, Arshad
    Masud, Haleema
    Ali, Mazhar
    Basit, Anila
    Ahmad, Waqas
    Younis, Faisal
    Yasmin, Rehana
    Khan, Afsar
    Jabbar, Abdul
    Husain, Masroor
    Butt, Zahid Ahmad
    JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 66 (04) : 412 - 418
  • [8] Accuracy and impact of Xpert MTB/RIF for the diagnosis of smear-negative or sputum-scarce tuberculosis using bronchoalveolar lavage fluid
    Theron, Grant
    Peter, Jonny
    Meldau, Richard
    Khalfey, Hoosain
    Gina, Phindile
    Matinyena, Brian
    Lenders, Laura
    Calligaro, Gregory
    Allwood, Brian
    Symons, Gregory
    Govender, Ureshnie
    Setshedi, Mashiko
    Dheda, Keertan
    THORAX, 2013, 68 (11) : 1043 - 1051
  • [9] Role of bronchial aspirate samples for the diagnosis of pulmonary tuberculosis in patients with negative smear and negative Xpert MTB/Rif in sputum
    Chesov, Dumitru
    Heyckendrof, Jan
    Rusu, Doina
    Munteanu, Oxana
    Chesov, Elena
    Cozlovschi, Victor
    Crudu, Valeriu
    Lange, Christoph
    Botnaru, Victor
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56