Amperometric third-generation hydrogen peroxide biosensor incorporating multiwall carbon nanotubes and hemoglobin

被引:72
|
作者
Qi, HL [1 ]
Zhang, CX [1 ]
Li, XR [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
electrochemistry; biosensor; hemoglobin; carbon nanotubes; hydrogen peroxide;
D O I
10.1016/j.snb.2005.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric third-generation hydrogen peroxide biosensor was designed by immobilizing hemoglobin (Hb) on a glassy carbon electrode modified with multiwall carbon nanotubes, (MWNT). The direct electron transfer of the Hb immobilized on the MWNT-modified electrode was observed. The formal potential of the immobilized Hb was -0.241 V versus Ag/AgCl (3 M NaCl) and the heterogeneous electron transfer rate constant was 0.58 s(-1) in a 0.20 M acetate buffer solution (pH 5.4). The immobilized Hb exhibited excellent electrocatalytic activity to reduce hydrogen peroxide in the absence and presence of oxygen, which facilitated designing an amperometric third-generation biosensor for hydrogen peroxide. In the presence of oxygen, the response to hydrogen peroxide of the designed biosensor at a potential of -0.35 V was linear in the concentration range from 6.0 x 10(-6) to 6.0 x 10(-3) M, and the detection limit was 1.2 x 10(-6) M. The relative standard deviation was 2.4% for nine successive assays at 1.0 x 10(-5) M hydrogen peroxide. The designed biosensor was applied to the determination of hydrogen peroxide in pharmaceutical injections with high sensitivity and rapid response. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:364 / 370
页数:7
相关论文
共 50 条
  • [1] Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles
    Chen, Shihong
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Lingyan
    Wang, Na
    Li, Xuelian
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1268 - 1274
  • [2] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    Zhang Jin-lei
    Tan Xue-cai
    Zhao Dan-dan
    Tan Sheng-wei
    Huang Zeng-wei
    Mi Yan
    Huang Zai-yin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (04) : 541 - 545
  • [3] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    ZHANG Jin-lei~(1
    2.Department of Chemistry and Life Science
    Chemical Research in Chinese Universities, 2010, 26 (04) : 541 - 545
  • [4] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized on DNA functionalized carbon nanotubes
    Zeng, Xiandong
    Li, Xuefang
    Liu, Xiaoying
    Liu, Yong
    Luo, Shenglian
    Kong, Bo
    Yang, Shanli
    Wei, Wanzhi
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 896 - 900
  • [5] A third-generation hydrogen peroxide biosensor fabricated with hemoglobin and Triton X-100
    Liu, XJ
    Xu, Y
    Ma, X
    Li, GX
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) : 284 - 288
  • [6] A hydrogen peroxide amperometric biosensor based on carbon nanotubes
    Mai Zhibin
    Tan Xuecai
    Zou Xiaoyong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (06) : 801 - 804
  • [7] A Third-Generation Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized in Carbon Nanotubes/ SBA-15 Film
    Fang, Zheng-Hui
    Lu, Li-Min
    Zhang, Xiao-Bing
    Li, Hong-Bo
    Yang, Bin
    Shen, Guo-Li
    Yu, Ru-Qin
    ELECTROANALYSIS, 2011, 23 (10) : 2415 - 2420
  • [8] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase cross-linked to multi-wall carbon nanotubes
    Shuxia Xu
    Xinfeng Zhang
    Tao Wan
    Chengxiao Zhang
    Microchimica Acta, 2011, 172 : 199 - 205
  • [9] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized in a tetrathiafulvalene-tetracyanoquinodimethane/multiwalled carbon nanotubes film
    Cao, Zhijun
    Jiang, Xueqin
    Xie, Qingji
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (02): : 222 - 227
  • [10] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase cross-linked to multi-wall carbon nanotubes
    Xu, Shuxia
    Zhang, Xinfeng
    Wan, Tao
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 199 - 205