Distal femoral torsion: Comparison of CT scan and intra operative navigation measurements during total knee arthroplasty A report of 70 cases

被引:31
|
作者
Galaud, B. [1 ,2 ]
Beauflis, P. [1 ]
Michaut, M. [1 ,2 ]
Abadie, P. [1 ,2 ]
Fallet, L. [3 ]
Boisrenoult, P. [1 ]
机构
[1] Ctr Hosp Versailles, Serv Orthoped Traumatol, F-78150 Le Chesnay, France
[2] CHU Cote Nacre, Dept Orthoped, F-14000 Caen, France
[3] Ctr Hosp Versailles, Serv Imagerie, F-78150 Le Chesnay, France
关键词
Distal epiphysial femoral torsion; CT scan; Computer assisted surgery; Total knee prothesis;
D O I
10.1016/j.rco.2008.03.039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction. - Proper positioning of the prosthesis components in total knee arthroplasty is an important factor for satisfactory outcomes such as mobility, pain and wear. If an independent cutting technique is performed, rotational alignment of the femoral component should adapt patient's specific anatomy. The distal epiphyseal femoral torsion (DEFT) is adjusted in order to align the prosthetic posterior condylar axis along the bone transepicondylar axis. The DEFT presents a high rate of interindividual variations. Computed tomography scanning produces reliable and reproducible measurement of the epiphyseal torsion, but this requires additional procedure. We therefore used intraoperative computed navigation for DEFT measurement, thus accurately adapting each patient's epiphyseal torsion during the procedure, without resorting to the preoperative CT scan. Material and methods. - This prospective study included 70 patients with arthritic knees who underwent TKA. Mean patient age was 74 years old. There were 52 women, 35 right knees, 33 genu varum, 19 genu valgum, 18 normal knees. DEFT was determined by preoperative CT scan, using the Yoshioka angle referencing. Distal epiphyseal femoral torsion measurement was carried out using the Navitrack(R) system (Orthosoft). The DEFT was the navigated measured angle between the transepicondylar axis and the posterior condylar axis manually located and digitized with an optically tracked stylus. The navigation system was therefore used as a simple digital measurement device to evaluate the distal. epiphyseal femoral torsion. We had established the reference transepicondylar axis as the line connecting the prominence of the medial and lateral epicondyles. During the procedure, we also carried out computer-assisted measurement of HKA axis in full extension and at 90 degrees of knee flexion. Correlation between the navigated HKA in full extension and HKA measured on the preoperative pangonogram (R-2 = 0.621) demonstrated a high reliability of the navigation system in the frontal plane. Results. - There was no correlation between the mean epiphyseat torsion determined with computer navigation and the epiphyseat torsion measured on the CT scan (R-2 = 0.09). Significant interindividual variations were reported. Navigated HKA at 90, of knee flexion was not correlated with navigated HKA in full extension (R-2 = 0.398) nor with epiphyseal torsion measured on the CT scan (R-2 = 0.063). Results demonstrated a major interindividual. variation. Discussion. - Our results report a large variability in distal epiphyseal femoral torsion measured with CT scan. Moreover, computed navigation does not provide a reliable and reproducible evaluation of the epiphyseal torsion. Due to inaccurate identification of femoral epicondyles, the related navigated measurement is not considered to be reliable and reproducible. Navigated HKA at 90, of knee flexion is not a fair indirect reflection of epiphyseal torsion. Computer-assisted navigation faits to provide direct or indirect, reliable and reproducible intraoperative measurement of distal epiphyseat femoral torsion. Preoperative CT scan is the only reliable method to produce accurate measurement of distal epiphyseal femoral torsion. (C) 2008 Elsevier Masson SAS. Tous droits reserves.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [1] Distal femoral fracture during primary total knee arthroplasty
    Delasotta, Lawrence A.
    Orozco, Fabio
    Miller, Adam G.
    Post, Zachary
    Ong, Alvin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 202 - 204
  • [2] Comparison of CT with intra-operative navigation reported implant position utilising a robotic assisted technique in total knee arthroplasty
    Sharma, Namit
    Berera, Vinnie
    Petterwood, Joshua
    MEDICAL ENGINEERING & PHYSICS, 2022, 108
  • [3] Navigation-Assisted Total Knee Arthroplasty for the Knee Retaining Femoral Intramedullary Nail, and Distal Femoral Plate and Screws
    Kim, Kwang-Kyoun
    Heo, Youn-Moo
    Won, Ye-Yeon
    Lee, Woo-Suk
    CLINICS IN ORTHOPEDIC SURGERY, 2011, 3 (01) : 77 - 80
  • [4] Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)
    Jabalameli, Mahmoud
    Moradi, Amin
    Bagherifard, Abolfazl
    Radi, Mehran
    Mokhtari, Tahmineh
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2016, 4 (02): : 122 - 127
  • [5] Intraoperative Femoral Condylar Fracture during Primary Total Knee Arthroplasty: Report of Two Cases
    Huang, Ze-yu
    Ma, Jun
    Shen, Bin
    Pei, Fu-xing
    ORTHOPAEDIC SURGERY, 2015, 7 (02) : 180 - 184
  • [6] Accelerometer-Based Computer Navigation for Performing the Distal Femoral Resection in Total Knee Arthroplasty
    Nam, Denis
    Nawabi, Danyal H.
    Cross, Michael B.
    Heyse, Thomas J.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09): : 1717 - 1722
  • [7] Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
    Birjandinejad, Ali
    Zandi, Reza
    Karimi, Elham
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (03): : 400 - 406
  • [8] Computer navigation is a useful intra-operative tool for joint line measurement in total knee arthroplasty
    Ee, Gerard
    Pang, Hee Nee
    Chong, Hwei Chi
    Tan, Mann Hong
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE, 2013, 20 (04): : 256 - 262
  • [9] Distal Femoral Valgus Resection Angle in Conventional Total Knee Arthroplasty-a CT Scanogram Study
    Basanagoudar, Praveen L.
    Satishkumar, Bhava R. J.
    Pattabiraman, Kirubakaran
    Kamath, Dinesh
    Ranganadham, A., V
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (03): : 181 - 188
  • [10] A Comparison of Variable Angle Versus Fixed Angle Distal Femoral Resection in Primary Total Knee Arthroplasty