Unbalanced Fault Analysis of Doubly Fed Induction Generator Drive System For Wind Turbine Applications

被引:0
|
作者
Yasa, Yusuf [1 ,2 ]
Sozer, Yilmaz
Mese, Erkan [2 ,3 ]
机构
[1] Univ Akron, ECE Dept, Akron, OH 44325 USA
[2] Yildiz Tech Univ, Dept Elect Engn, Istanbul, Turkey
[3] Yildiz Tech Univ, Dept Elect & Comp Engn, Akron, OH 44325 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents detailed analysis of the doubly fed induction generator (DFIG), converters and step-up transformer under normal and fault conditions for wind turbine applications. 2.5 MW DFIG is modeled through finite element analysis in Ansoft-Maxwell, and the simulation is coupled to Ansoft-Simplorer and Matlab-Simulink for the drive circuit and controller implementation. Single phase to ground short circuit which has the highest probability to occur in the grid is tested through coupled simulators. The effect of short circuit stator current on the rotor currents are analyzed for rotor side converter protection. The FFT analysis of the stator and rotor fluxes in simulation during fault conditions are carried to be able to develop advanced control techniques in eliminating the harmonics and protecting the overall drive system. Experimental 7.5 HP DFIG test system has been developed to verify the simulation results. The FFT analysis of stator fluxes under fault condition from experimental results agrees well with the simulation results.
引用
收藏
页码:2953 / 2960
页数:8
相关论文
共 50 条
  • [1] A Supersynchronous Doubly Fed Induction Generator Option for Wind Turbine Applications
    Lipo, T. A.
    2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 130 - 134
  • [2] Design and Analysis of an Axial Flux Doubly Fed Induction Generator for Wind Turbine Applications
    Das, Shuvajit
    Sozer, Yilmaz
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 442 - 447
  • [3] WIND TURBINE GENERATOR SYSTEM BASED ON CASCADED DOUBLY FED INDUCTION GENERATOR
    Silva de Vasconcelos, Carlos Henrique
    Ferreira, Antonio Carlos
    Stephan, Richard Magdalena
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [4] Actuator Fault Diagnosis Approach for Doubly Fed Induction Generator of Wind Turbine
    Idrissi, I.
    Chafouk, H.
    El Bachtiri, R.
    2019 4TH CONFERENCE ON CONTROL AND FAULT TOLERANT SYSTEMS (SYSTOL), 2019, : 378 - 383
  • [5] A fault ride through scheme for doubly fed induction generator wind turbine
    Ling Y.
    Ling, Yu (pleasurely@126.com), 2018, Taylor and Francis Ltd. (15): : 71 - 79
  • [6] Flicker mitigation in a doubly fed induction generator wind turbine system
    Machmoum, Mohamed
    Hatoum, Ahmad
    Bouaouiche, Toufik
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2010, 81 (02) : 433 - 445
  • [7] Analysis of Doubly Fed Induction Generator-based wind turbine system for fault ride through capability investigations
    Tuka, Milkias Berhanu
    Endale, Salem Molla
    WIND ENGINEERING, 2023, 47 (06) : 1132 - 1150
  • [8] Fault ride-through performance of wind turbine with doubly fed induction generator
    Zou, Heping
    Sun, Hui
    Zou, Jiyan
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1607 - 1611
  • [9] Wind Turbine using Doubly-Fed Induction Generator Protection during Fault
    Ibrahima, Kone
    Zhao, Chengyong
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON INFORMATION, BUSINESS AND EDUCATION TECHNOLOGY (ICIBET 2013), 2013, 26 : 1330 - 1336
  • [10] A DOUBLY-FED INDUCTION GENERATOR DRIVE FOR A WIND ENERGY CONVERSION SYSTEM
    Barendse, P. S.
    Pillay, P.
    SAIEE AFRICA RESEARCH JOURNAL, 2006, 97 (04): : 274 - 280