The size 11/2 ProSeal™ laryngeal mask airway in infants:: A randomized, crossover investigation with the Classic™ laryngeal mask airway

被引:55
|
作者
Goldmann, K [1 ]
Roettger, C [1 ]
Wulf, H [1 ]
机构
[1] Univ Marburg, Dept Anesthesia & Intens Care Therapy, D-35033 Marburg, Germany
来源
ANESTHESIA AND ANALGESIA | 2006年 / 102卷 / 02期
关键词
D O I
10.1213/01.ane.0000194300.56739.1a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Many problems with the Classic (TM) laryngeal mask airway (CLMA) in infants are believed to be related to its inadequate cuff design. One of the main limitations of the CLMA is that the resulting low-pressure seal can be inadequate for positive pressure ventilation (PPV). The ProSeal (TM) LMA (PLMA), a new laryngeal mask airway with a modified cuff, has been shown to form a more effective seal than the CLMA in children. The first infant size PLMA, size 11/2, became available recently. We studied 30 anesthetized, nonparalyzed infants aged 1.5 mo (2-30 mo) and weighing 9 kg (5-12 kg). The CLMA and PLMA were inserted in random order into each patient. Airway leak pressure and maximum tidal volume were measured. Ease of insertion, quality of initial airway, and fiberoptic position were also determined. Gastric tube placement was assessed for the PLMA. The mean airway leak pressure in neutral head position (26.7 versus 18.9 cm H2O), maximum flexion (35.6 versus 28.2 cm H2O), and the mean maximum tidal volume (312 versus 260 mL) were significantly higher for the PLMA (P < 0.01.). Air entered the stomach in eight patients with the CLMA but did not with the PLMA. Gastric tube placement was possible in all but one patient. In three patients, the use of the PLMA led to some degree of clinically relevant compression of the larynx. The size 11/2 PLMA seems to be a more suitable device for airway maintenance in infants than the same size CLMA. The ability to insert a gastric tube at the same time, and a significantly higher airway leak pressure than with the CLMA, may have important implications for its use for PPV in infants.
引用
收藏
页码:405 / 410
页数:6
相关论文
共 50 条
  • [1] The Size 1 ProSeal™ laryngeal mask airway in infants: a randomized, noncrossover study with the Classic™ laryngeal mask airway
    Lopez-Gil, Maite
    Mantilla, Ignacio
    Blanco, Teresa
    Teigell, Enrique
    Hervias, Monica
    Fernandez-Lopez, Rosa
    PEDIATRIC ANESTHESIA, 2012, 22 (04) : 365 - 370
  • [2] Size 2 ProSeal™ laryngeal mask airway:: a randomized, crossover investigation with the standard laryngeal mask airway in paediatric patients
    Goldmann, K
    Jakob, C
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 385 - 389
  • [3] Use of the size 3 ProSeal® laryngeal mask airway in children.: Results of a randomized crossover investigation with the Classic® laryngeal mask airway
    Goldmann, K
    Roettger, C
    Wulf, H
    ANAESTHESIST, 2006, 55 (02): : 148 - 153
  • [4] A randomized crossover comparison of the size 2 1/2 laryngeal mask airway ProSeal™ versus Laryngeal Mask Airway-Classic™ in pediatric patients
    Goldmann, K
    Jakob, C
    ANESTHESIA AND ANALGESIA, 2005, 100 (06): : 1605 - 1610
  • [5] Proseal Laryngeal mask airway or Classic Laryngeal mask airway in spontaneous ventilation?
    Galarioti, V.
    Michaloliakou, Ch.
    Kalanzi, N.
    Pagoulatou, A.
    Andrianopoulou, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 68 - 68
  • [6] A randomized study to compare ProSeal laryngeal mask airway with classic laryngeal mask airway in anesthetized patients
    Taxak, Susheela
    Kaur, Kiranpreet
    Kaushik, Shubham
    Singh, Rita
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2013, 29 (04) : 285 - 290
  • [7] The ProSeal laryngeal mask airway - A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients
    Brimacombe, J
    Keller, C
    ANESTHESIOLOGY, 2000, 93 (01) : 104 - 109
  • [8] A RANDOMIZED CROSSOVER COMPARISON OF THE LARYNGEAL MASK AIRWAY PROSEAL AND LARYNGEAL MASK AIRWAY SUPREME IN ANESTHETIZED ADULT PATIENTS
    Jannu, Vinayaka
    Dhorigol, M. G.
    Sanikop, C. S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (85): : 14828 - 14833
  • [9] Randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed anaesthetized patients
    Cook, TM
    Nolan, JP
    Verghese, C
    Strube, PJ
    Lees, M
    Millar, JM
    Baskett, PJF
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (04) : 527 - 533
  • [10] The ProSeal laryngeal mask airway
    Dalgleish, DJ
    Dolgner, M
    ANAESTHESIA, 2001, 56 (10) : 1010 - 1010