Magnetic Resonance Imaging: An Accurate, Radiation-Free, Alternative to Computed Tomography for the Primary Imaging and Three-Dimensional Reconstruction of the Bony Orbit

被引:25
|
作者
Schmutz, Beat [1 ]
Rahmel, Benjamin [1 ]
McNamara, Zeb [1 ]
Coulthard, Alan [1 ]
Schuetz, Michael [1 ]
Lynham, Anthony [1 ]
机构
[1] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld 4059, Australia
关键词
VOLUME MEASUREMENT; FRACTURES; IMPLANTS; COIL; MRI; CAD/CAM; WALL;
D O I
10.1016/j.joms.2013.08.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the extent to which the accuracy of magnetic resonance imaging (MRI) based virtual 3-dimensional (3D) models of the intact orbit can approach that of the gold standard, computed tomography (CT) based models. The goal was to determine whether MRI is a viable alternative to CT scans in patients with isolated orbital fractures and penetrating eye injuries, pediatric patients, and patients requiring multiple scans in whom radiation exposure is ideally limited. Materials and Methods: Patients who presented with unilateral orbital fractures to the Royal Brisbane and Women's Hospital from March 2011 to March 2012 were recruited to participate in this cross-sectional study. The primary predictor variable was the imaging technique (MRI vs CT). The outcome measurements were orbital volume (primary outcome) and geometric intraorbital surface deviations (secondary outcome) between the MRI- and CT-based 3D models. Results: Eleven subjects (9 male) were enrolled. The patients' mean age was 30 years. On average, the MRI models underestimated the orbital volume of the CT models by 0.50 +/- 0.19 cm(3). The average intraorbital surface deviation between the MRI and CT models was 0.34 +/- 0.32 mm, with 78 +/- 2.7% of the surface within a tolerance of +/-0.5 mm. Conclusions: The volumetric differences of the MRI models are comparable to reported results from CT models. The intraorbital MRI surface deviations are smaller than the accepted tolerance for orbital surgical reconstructions. Therefore, the authors believe that MRI is an accurate radiation-free alternative to CT for the primary imaging and 3D reconstruction of the bony orbit. (C) 2014 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [1] Magnetic resonance imaging for three-dimensional printing of the bony orbit: is clinical use imminent?
    Cooper, T.
    Schmutz, B.
    Hsu, E.
    Lynham, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (04) : 483 - 490
  • [2] Combination of Magnetic Resonance Imaging and Neutron Computed Tomography for Three-Dimensional Rhizosphere Imaging
    Haber-Pohimeler, S.
    Toetzke, S. C.
    Lehmann, E.
    Kardjilov, N.
    Pohlmeier, A.
    Oswald, S. E.
    VADOSE ZONE JOURNAL, 2019, 18 (01): : 1 - 11
  • [3] Three-dimensional imaging of the left atrium and pulmonary veins: Computed tomography or magnetic resonance imaging?
    Schwartzman, D
    Lacomis, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 132A - 132A
  • [4] Magnetic Resonance Imaging Versus Computed Tomography for Three-Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review
    Florkow, Mateusz C.
    Willemsen, Koen
    Mascarenhas, Vasco V.
    Oei, Edwin H. G.
    Stralen, Marijn
    Seevinck, Peter R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (01) : 11 - 34
  • [5] Comparing accuracy of cochlear measurements on magnetic resonance imaging and computed tomography: A step towards radiation-free cochlear implantation
    Swarup, Anurita
    Karakkandy, Vinusree
    Chappity, Preetam
    Naik, Suprava
    Behera, Sanjay Kumar
    Parida, Pradipta Kumar
    Grover, Mohnish
    Gupta, Gaurav
    Giri, Prajna Paramita
    Sarkar, Saurav
    Pradhan, Pradeep
    Samal, Dillip Kumar
    Veetil, Aswathi Kallyadan
    Adhikari, Asutosh
    Nayak, Saurav
    JOURNAL OF OTOLOGY, 2023, 18 (04) : 208 - 213
  • [6] Anatomy and Correlation of the Coracoid Process and Coracoclavicular Ligament Based on Three-Dimensional Computed Tomography Reconstruction and Magnetic Resonance Imaging
    Xin, Lan
    Luo, Jin
    Chen, Mingying
    He, Bing
    Tang, Bi
    Tang, Chunyang
    Zhang, Dongyu
    Zhang, Lei
    MEDICAL SCIENCE MONITOR, 2021, 27
  • [7] Comparing accuracy of cochlear measurements on magnetic resonance imaging and computed tomography: A step towards radiation-free cochlear implantation
    Anurita Swarup
    Vinusree Karakkandy
    Preetam Chappity
    Suprava Naik
    Sanjay Kumar Behera
    Pradipta Kumar Parida
    Mohnish Grover
    Gaurav Gupta
    Prajna Paramita Giri
    Saurav Sarkar
    Pradeep Pradhan
    Dillip Kumar Samal
    Aswathi Kallyadan Veetil
    Asutosh Adhikari
    Saurav Nayak
    JournalofOtology, 2023, 18 (04) : 208 - 213
  • [8] Evaluation of ossification of the posterior longitudinal ligament by three-dimensional computed tomography and magnetic resonance imaging
    Kawaguchi, Yoshiharu
    Urushisaki, Aya
    Seki, Shoji
    Hori, Takeshi
    Asanuma, Yumiko
    Kimura, Tomoatsu
    SPINE JOURNAL, 2011, 11 (10): : 927 - 932
  • [9] Quantification of a glenoid defect with three-dimensional computed tomography and magnetic resonance imaging: A cadaveric study
    Huijsmans, Pol E.
    Haen, Pieter S.
    Kidd, Martin
    Dhert, Wouter J.
    van der Hulst, Victor P. M.
    Willems, W. Jaap
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (06) : 803 - 809
  • [10] Imaging of the pediatric orbit and visual pathways - Computed tomography and magnetic resonance imaging
    Davis, PC
    Hopkins, KL
    NEUROIMAGING CLINICS OF NORTH AMERICA, 1999, 9 (01) : 93 - +