Ultrasensitive measurement of gas refractive index using an optical nanofiber coupler

被引:68
|
作者
Li, Kaiwei [1 ]
Zhang, Nan [1 ,2 ]
Zhang, Nancy Meng Ying [1 ,2 ]
Liu, Guigen [3 ]
Zhang, Ting [1 ]
Wei, Lei [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Nanyang Technol Univ, THALES, CNRS, CINTRA,UMI3288, Res Techno Plaza,50 Nanyang Dr, Singapore 637553, Singapore
[3] Univ Nebraska, Dept Elect & Comp Engn, Lincoln, NE 68588 USA
关键词
FABRY-PEROT-INTERFEROMETER; PHOTONIC CRYSTAL FIBER; AIR;
D O I
10.1364/OL.43.000679
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report an ultrasensitive gas refractive index (RI) sensor based on optical nanofiber couplers (ONCs). Theoretical analysis reveals that a dispersion turning point (DTP) exists when the diameter of the coupler is below 1000 nm. Leveraging this DTP, the gas RI sensitivity can be significantly improved to infinity. Then we experimentally demonstrate a DTP and achieve ultrahigh sensitivities of 46,470 nm/refractive index unit (RIU) and -45,550 nm/RIU around the DTP using an ONC with a diameter of 700 nm. More importantly, the unique twin dips/peaks interference characteristics around the DTP offers further enhancement on the sensitivity to 92,020 nm/RIU. The demonstrated sensor not only shows vast potential in ultrasensitive pressure sensing, acoustic sensing, gas sensing, and gas phase biomarker detection, but also provides a new tool for nonlinear optics, ultrafast optics, quantum optics, and ultracold atom optics. (C) 2018 Optical Society of America
引用
收藏
页码:679 / 682
页数:4
相关论文
共 50 条
  • [1] Measurement of refractive index of powder by prism coupler
    Chen, Feng
    Xu, Qing
    Zhang, Pei
    Zhang, Zi-Bo
    Wong, Wing-Han
    Pun, Edwin Yue-Bun
    Zhang, De-Long
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (09):
  • [2] High-Sensitivity, Large Dynamic Range Refractive Index Measurement Using an Optical Microfiber Coupler
    Wang, Jiajia
    Li, Xiong
    Fu, Jun
    Li, Kaiwei
    SENSORS, 2019, 19 (23)
  • [3] Narrow rectangular slit in optical fiber core for ultrasensitive refractive index measurement
    Wang, Qiaoben
    Wang, D. N.
    OPTICAL FIBER TECHNOLOGY, 2024, 83
  • [4] Ultrasensitive measurement of temperature using an isopropanol-sealed optical microfiber coupler
    Zhang, Yundong
    Zhao, Li
    Chen, Yunhao
    Wang, Jinfang
    OPTICAL, OPTO-ATOMIC, AND ENTANGLEMENT-ENHANCED PRECISION METROLOGY, 2019, 10934
  • [5] High-refractive-index measurement with an elastomeric grating coupler
    Kocabas, A
    Ay, F
    Dâna, A
    Kiyat, I
    Aydinli, A
    OPTICS LETTERS, 2005, 30 (23) : 3150 - 3152
  • [6] GAS ANALYSIS BY REFRACTIVE INDEX MEASUREMENT
    EDMONDSON, W
    BRITISH JOURNAL OF ANAESTHESIA, 1957, 29 (12) : 570 - 574
  • [7] LASER MEASUREMENT OF REFRACTIVE INDEX OF A GAS
    YAP, FY
    AMERICAN JOURNAL OF PHYSICS, 1971, 39 (02) : 224 - &
  • [8] Ultrasensitive Refractive-Index Sensors Based on Tapered Fiber Coupler With Sagnac Loop
    Pu, Shengli
    Luo, Longfeng
    Tang, Jiali
    Mao, Lianmin
    Zeng, Xianglong
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (10) : 1073 - 1076
  • [9] ULTRASENSITIVE OPTICAL-ROTATION AND REFRACTIVE-INDEX MEASUREMENTS
    YEUNG, ES
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 426 : 138 - 144
  • [10] Ultrasensitive tapered optical fiber refractive index glucose sensor
    Ujah, Erem
    Lai, Meimei
    Slaughter, Gymama