Comparison of adjacent segment degeneration after successful posterolateral fusion with unilateral or bilateral pedicle screw instrumentation: a minimum 10-year follow-up

被引:40
|
作者
Kim, Tae-Hwan [1 ]
Lee, Byung H. [1 ]
Moon, Seong-Hwan [1 ]
Lee, Seung-Hwan [1 ]
Lee, Hwan-Mo [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Orthoped Surg, Seoul 120752, South Korea
来源
SPINE JOURNAL | 2013年 / 13卷 / 10期
关键词
Posterolateral fusion; Adjacent segment degeneration; Unilateral pedicle screw; Lumbar spinal stenosis; Spondylolisthesis; LUMBAR INTERBODY FUSION; SPINAL STENOSIS; VERTEBRAL BODY; BONE; SPONDYLOLISTHESIS; FIXATION; ARTHRODESIS; DISEASE;
D O I
10.1016/j.spinee.2013.07.431
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: In the instrumented fusion, adjacent segment facet joint violation or impingement by pedicle screws is unavoidable especially in cephalad segment, despite taking specific intraoperative precautions in terms of surgical approach. In such circumstances, unlike its original purpose, unilateral pedicle screw instrumentation can contribute to reduce the degeneration of cephalad adjacent segment by preventing contralateral cephalad adjacent facet joint from the unavoidable injury by pedicle screw insertion. However, to our knowledge, no long-term follow-up study has compared adjacent segment degeneration (ASD) between unilateral and bilateral pedicle screw instrumented fusion. PURPOSE: To compare ASD after successful posterolateral fusion using either unilateral or bilateral pedicle screw instrumentation for patients with lumbar spinal stenosis and/or Grade 1 spondylolisthesis. STUDY DESIGN: Retrospective case-control study. PATIENT SAMPLE: One hundred forty-seven patients who had undergone one-or two-level posterolateral fusion with unilateral or bilateral pedicle screw instrumentation for lumbar spinal stenosis with or without low-grade spondylolisthesis and achieved successful fusion, with a minimum 10-year follow-up. OUTCOME MEASURE: The occurrence of radiologic ASD, Oswestry disability index (ODI) scores, and revision rates. METHODS: A total of 194 consecutive patients were contacted and encouraged to visit our hospital and to participate in our study. Radiologic ASD was evaluated at three motion segments: cephalad adjacent segment (first cephalad adjacent segment), one cephalad to cephalad adjacent segment (second cephalad adjacent segment), and caudal adjacent segment. Clinical outcomes were compared by ODI scores and revision rates. RESULTS: In total, 147 of 194 (75.8%) patients were available for at least 10 years of radiologic and clinical follow-up. Adjacent segment degeneration (in first cephalad or caudal adjacent segment) was noted in 55.9% (33 of 59 patients) of the unilateral group and 72.7% (64 of 88 patients) of the bilateral group (p=.035). The occurrence of ASD in each first cephalad and caudal adjacent segment was not significantly different between groups but that in second cephalad adjacent segment was significantly different between groups (p=.004). Clinical outcomes according to ODI showed significant difference between groups (p=.016), especially when ODI scores were compared in patients with ASD (p=.004). CONCLUSIONS: In a minimum 10-year follow-up retrospective study of posterolateral fusion for lumbar spinal stenosis and/or Grade 1 spondylolisthesis, unilateral pedicle screw instrumentation showed a lower rate of radiologic ASD, especially in second cephalad adjacent segment, and a better clinical outcome by ODI. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1208 / 1216
页数:9
相关论文
共 50 条
  • [1] Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation - A minimum 5-year follow-up
    Cheh, Gene
    Bridwell, Keith H.
    Lenke, Lawrence G.
    Buchowski, Jacob M.
    Daubs, Michael D.
    Kim, Yongjung
    Baldus, Christy
    SPINE, 2007, 32 (20) : 2253 - 2257
  • [2] Comparison of adjacent segment disease after minimally invasive versus open lumbar fusion: a minimum 10-year follow-up
    Jeong, Tae Seok
    Son, Seong
    Lee, Sang Gu
    Ahn, Yong
    Jung, Jong Myung
    Yoo, Byung Rhae
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (04) : 525 - 533
  • [3] Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-up
    Jigar Anandjiwala
    Jun-Yeong Seo
    Kee-Yong Ha
    In-Soo Oh
    Dong-Cheul Shin
    European Spine Journal, 2011, 20 : 1951 - 1960
  • [4] Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-up
    Anandjiwala, Jigar
    Seo, Jun-Yeong
    Ha, Kee-Yong
    Oh, In-Soo
    Shin, Dong-Cheul
    EUROPEAN SPINE JOURNAL, 2011, 20 (11) : 1951 - 1960
  • [5] The Difference in Superior Adjacent Segment Pathology After Lumbar Posterolateral Fusion by Using 2 Different Pedicle Screw Insertion Techniques in 9-Year Minimum Follow-up
    He, Baorong
    Yan, Liang
    Guo, Hua
    Liu, Tuanjiang
    Wang, Xiaodong
    Hao, Dingjun
    SPINE, 2014, 39 (14) : 1093 - 1098
  • [6] LUMBOSACRAL FUSION WITH PEDICULAR SCREW PLATING INSTRUMENTATION - A 10-YEAR FOLLOW-UP
    ROYCAMILLE, R
    BENAZET, JP
    DESAUGE, JP
    KUNTZ, F
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 : 100 - 104
  • [7] A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation
    Glaser, J
    Stanley, M
    Sayre, H
    Woody, J
    Found, E
    Spratt, K
    SPINE, 2003, 28 (13) : 1390 - 1395
  • [8] Clinical adjacent-segment pathology after anterior cervical discectomy and fusion: results after a minimum of 10-year follow-up
    Chung, Jae-Yoon
    Kim, Sung-Kyu
    Jung, Sung-Taek
    Lee, Keun-Bae
    SPINE JOURNAL, 2014, 14 (10): : 2290 - 2298
  • [9] Comparison of Adjacent Segment Degeneration After Minimally Invasive or Open Transforaminal Lumbar Interbody Fusion A Minimum 5-Year Follow-up
    Jia, Jun
    Chen, Cong
    Wang, Peng
    Wang, Lianlei
    Liu, Xinyu
    CLINICAL SPINE SURGERY, 2023, 36 (01): : E45 - E50
  • [10] Adjacent Segment Degeneration After Lumbar Interbody Fusion With Percutaneous Pedicle Screw Fixation for Adult Low-Grade Isthmic Spondylolisthesis: Minimum 3 Years of Follow-up
    Bae, Jun Seok
    Lee, Sang-Ho
    Kim, Jin-Sung
    Jung, Byungjoo
    Choi, Gun
    NEUROSURGERY, 2010, 67 (06) : 1600 - 1607