MANAGEMENT OF REFRACTORY LARGE MACULAR HOLE WITH AUTOLOGOUS NEUROSENSORY RETINAL FREE FLAP TRANSPLANTATION

被引:24
|
作者
Chang, Yo-Chen [1 ,2 ,3 ]
Liu, Pei-Kang [3 ]
Kao, Tzu-En [3 ,4 ]
Chen, Kuo-Jen [5 ]
Chen, Yi-Hsien [3 ]
Chiu, Wei-Jun [3 ]
Wu, Kwou-Yeung [2 ,3 ]
Wu, Wen-Chuan [2 ,3 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Municipal Ta Tung Hosp, Dept Ophthalmol, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Sch Med, Dept Ophthalmol, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ Hosp, Dept Ophthalmol, Kaohsiung, Taiwan
[4] Yuans Gen Hosp, Dept Ophthalmol, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Kaohsiung Municipal Siaogang Hosp, Dept Ophthalmol, Kaohsiung, Taiwan
关键词
autologous; free retinal flap; giant macular hole; refractory; transplantation; INTERNAL LIMITING MEMBRANE; SURGERY; VITRECTOMY; OUTCOMES; CLOSURE; SERUM;
D O I
10.1097/IAE.0000000000002734
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the morphological and functional outcome of refractory large macular hole (MH) with autologous neurosensory retinal free flap transplantation. Methods: This case series enrolled 10 patients suffering from refractory large MH at Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. All eyes underwent pars plana vitrectomy, a neurosensory retinal free flap with a 1.5 to 2-MH diameter was harvested. We used an adhesive agent such as whole blood or Viscoat to assist the stabilization of the retinal free flap and then use tamponade silicone oil to tamponade the vitreous cavity. Silicone oil was removed 6 months postoperatively. Main outcome measures including closure of MH and change in best-corrected visual acuity change were recorded. Results: The mean age was 64.9 +/- 11.5 years. Before presentation, all cases had received at least two vitreoretinal procedures including vitrectomy, internal limiting membrane peeling, and fluid-gas exchange. At last visit, closure of the MH was achieved in 9 of 10 (90%) cases. The mean preoperative best-corrected visual acuity and that after 12 months of surgery improved from 1.65 +/- 0.43 logarithm of minimum angle of resolution to 0.88 +/- 0.49 logarithm of minimum angle of resolution (P < 0.001). Conclusion: For eyes with refractory or large MH, autologous neurosensory retinal free flap under silicone oil tamponade may provide a new option to improve the anatomical and function outcome, especially in cases where insufficient internal limiting membrane is left.
引用
收藏
页码:2134 / 2139
页数:6
相关论文
共 50 条
  • [1] Autologous Neurosensory Retinal Free Flap Treatment for a Large Macular Hole
    Lazic, Ratimir
    Draca, Natasa
    Cerovic, Vesna
    Katic, Dinko
    Mladenovski, Stefan
    Gabric, Nikica
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (09): : E89 - E92
  • [2] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Kenan Sonmez
    International Ophthalmology, 2021, 41 : 1415 - 1425
  • [3] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Sonmez, Kenan
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (04) : 1415 - 1425
  • [4] Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap
    Neves, Filipe Sousa
    Braga, Joana
    Sepulveda, Paula
    Bilhoto, Miguel
    CASE REPORTS IN OPHTHALMOLOGY, 2019, 10 (02): : 160 - 164
  • [5] Long-Term Follow-Up of Refractory Large Macular Hole with Autologous Neurosensory Retinal Free Flap Transplantation
    Lee, Po-Yen
    Chang, Yo-Chen
    Liu, Pei-Kang
    Kao, Tzu-En
    Wu, Horng-Jiun
    Chen, Kuo-Jen
    Wu, Kwou-Yeung
    Cheng, Kai-Chun
    Wu, Wen-Chuan
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [6] Management of refractory macular hole with blood and gas-assisted autologous neurosensory retinal free flap transplantation: a case report
    Pei-Kang Liu
    Yo-Chen Chang
    Wen-Chuan Wu
    BMC Ophthalmology, 18
  • [7] Management of refractory macular hole with blood and gas-assisted autologous neurosensory retinal free flap transplantation: a case report
    Liu, Pei-Kang
    Chang, Yo-Chen
    Wu, Wen-Chuan
    BMC OPHTHALMOLOGY, 2018, 18
  • [8] AUTOLOGOUS NEUROSENSORY RETINAL FLAP FOR CLOSURE OF REFRACTORY MACULAR HOLE IN A PATIENT WITH MACULAR TELANGIECTASIA
    Hewson, Andrew
    McAllister, Andrew
    Reddie, Ian
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 138 - 139
  • [9] Autologous Neurosensory Retinal Free Flap for Closure of Refractory Myopic Macular Holes
    Grewal, Dilraj S.
    Mahmoud, Tamer H.
    JAMA OPHTHALMOLOGY, 2016, 134 (02) : 229 - 230
  • [10] INTRAOPERATIVE AND POSTOPERATIVE MONITORING OF AUTOLOGOUS NEUROSENSORY RETINAL FLAP TRANSPLANTATION FOR A REFRACTORY MACULAR HOLE ASSOCIATED WITH HIGH MYOPIA
    Takeuchi, Jun
    Kataoka, Keiko
    Shimizu, Hideyuki
    Tomita, Ryo
    Kominami, Taro
    Ushida, Hiroaki
    Kaneko, Hiroki
    Ito, Yasuki
    Terasaki, Hiroko
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (05): : 921 - 930