Comparison of three different phantoms used for Winston -Lutz test with Artiscan software

被引:5
|
作者
Szweda, Hubert [1 ]
Graczyk, Kinga [2 ]
Radomiak, Dawid [1 ]
Matuszewski, Krzysztof [1 ]
Pawalowski, Bartosz [1 ]
机构
[1] Maria Sklodowska Curie Greater Poland Canc Ctr, Dosimetry Dept Med Equipment, Poznan, Poland
[2] Uniwersytet Adama Mickiewicza Poznaniu, Wydzial Fizyki, Poznan, Poland
关键词
Winston-Lutz test; IGRT; Artiscan; QA; IMAGE-GUIDANCE STRATEGIES;
D O I
10.1016/j.rpor.2020.03.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: One of the most important test in every quality assurances process of medical linear accelerators is the Winston-Lutz test, allowing an evaluation of the treatment isocentre in the light of uncertainty of the position of the collimator, the gantry and the couch. Aim: The purpose of this work was analysis of the results of the Winston-Lutz test performed with three different phantoms for two different accelerators. Materials and methods: Measurements were performed on two Varian machines: TrueBeam equipped with aS1200 EPID and TrueBeam equipped with aS1000 EPID. During the study three different phantoms dedicated for verification of the radiation isocentre were used: PTW Isoball, AQUILAB Isocentre Phantom and Varian Isocentre Cube. Analysis of the DICOM images was performed in Artiscan software. Results: For TrueBeam with as1200 EPID, gantry MV isocentre was about 0.18 mm larger for Varian Isocentre Cube than for two other phantoms used in this study. The largest variability of this parameter was observed for the couch. The results differed to 1.16 mm. For TrueBeam with as1000 EPID, results for collimator isocentre with PTW Isoball phantom were about 0.10 mm larger than for two other phantoms. For the gantry, results obtained with Varian Isocentre Cube were 0.21 mm larger. Conclusion: The obtained results for all three phantoms are within the accepted tolerance range. The largest differences were observed for treatment couch, which may be related to the phantom mobility during couch movement. (C) 2020 Published by Elsevier B.V. on behalf of Greater Poland Cancer Centre.
引用
收藏
页码:351 / 354
页数:4
相关论文
共 50 条
  • [1] Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy
    Torfeh, Tarraf
    Beaumont, Stephane
    Bonnet, David
    Barbotteau, Yves
    Guedon, JeanPierre
    Normand, Nicolas
    Denis, Eloise
    Fenoglietto, Pascal
    Ailleres, Norbert
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [2] COMPARISON OF TWO EVALUATION PROGRAMS FOR THE WINSTON LUTZ TEST
    Glessmer, S.
    Maass, T.
    Fehlauer, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S548 - S548
  • [3] Evaluation of a web-based software for "Winston-Lutz" test analysis
    Calvo Ortega, J. F.
    Hermida-Lopez, M.
    Moragues Femenia, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1116 - S1117
  • [4] Comparison of two Evaluators for EPID Images of the Winston-Lutz Test
    Glessmer, S.
    Maass, T.
    Fehlauer, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 107 - 107
  • [5] Three-Dimensional Winston-Lutz Test Using a Reusable Radiochromic Gel Dosimeter
    Ono, K.
    Fujino, K.
    Kinoshita, K.
    Hayashi, S.
    Akagi, Y.
    Hirokawa, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E413 - E414
  • [6] Comparison of different phantoms used in digital diagnostic imaging
    Bor, Dogan
    Unal, Elif
    Uslu, Anil
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 160 - 166
  • [7] A study of Winston–Lutz test on two different electronic portal imaging devices and with low energy imaging
    Paul B. Ravindran
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 677 - 685
  • [8] A study of Winston-Lutz test on two different electronic portal imaging devices and with low energy imaging
    Ravindran, Paul B.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (03) : 677 - 685
  • [9] COMPARISON OF DIFFERENT MATERIALS FOR TEST PHANTOMS IN DIAGNOSTIC-RADIOLOGY
    SANDBORG, M
    CARLSSON, GA
    PERSLIDEN, J
    DANCE, DR
    RADIATION PROTECTION DOSIMETRY, 1993, 49 (1-3) : 345 - 347
  • [10] Glioblastoma Segmentation: Comparison of Three Different Software Packages
    Fyllingen, Even Hovig
    Stensjoen, Anne Line
    Berntsen, Erik Magnus
    Solheim, Ole
    Reinertsen, Ingerid
    PLOS ONE, 2016, 11 (10):