Morphometric evaluation and surgical implications of the infraorbital groove, canal and foramen on cone-beam computed tomography and a review of literature

被引:25
|
作者
Bahsi, I [1 ]
Orhan, M. [1 ]
Kervancioglu, P. [1 ]
Yalcin, E. D. [2 ]
机构
[1] Gaziantep Univ, Fac Med, Dept Anat, Gaziantep, Turkey
[2] Gaziantep Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Gaziantep, Turkey
关键词
cone-beam computed tomography; infraorbital foramen; infraorbital canal; infraorbital groove; infraorbital nerve blockage; CLEFT-LIP REPAIR; NERVE BLOCK; MAXILLARY SINUS; ANTHROPOMETRIC ANALYSIS; CUTANEOUS DISTRIBUTION; ANTERIOR MAXILLA; MENTAL FORAMINA; ANATOMY; LOCATION; CLASSIFICATION;
D O I
10.5603/FM.a2018.0084
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Background: The purpose of this study is to evaluate the anatomy, morphometry, and variations of infraorbital groove (lOG), infraorbital canal (IOC) and infraorbital foramen (IOF) on the cone-beam computed tomography (CBCT) images and to investigate their relations with surrounding structures. Methods: IOG, IOC and IOF were evaluated retrospectively in CBCT images of 75 female (F) and 75 male (M) cases with a range of 18-65 years (F: 37.62 +/- +/- 13.55, M: 37.53 +/- 15.87) by Planmeca Romexis programme. IOG, IOC and IOF were examined bilaterally (300 sides) in the cases. The 13 parameters were measured on these images in axial, sagittal and coronal planes. Results: There was a very weak positive correlation between the age and the angle between IOC and IOG (p = 0.015, r = 0.198), there was a weak positive correlation between the age and skin thickness (p = 0.001, r = 0.281), and there was no correlation between the age and other parameters. A total of 21 (7%) IOCs were detected in maxillary sinus, bilaterally in 6 cases and unilaterally in 9 cases (5 on the left, 4 on the right). In 1 case, bilaterally, IOC was separated 2 canals while running anteriorly in the maxillary sinus. The larger one was directed to IOF in its normal course and the smaller one was directed to lateral wall of nasal cavity and opened to the inferior nasal meatus in front of the opening of nasolacrimal duct. Conclusions: We suggest that the parameters found in the present study may facilitate prediction of the location of the infraorbital nerve. Knowledge of this exact position in relation to easily measurable parameters may decrease the risk of infraorbital nerve injury during surgical approaches directed to this region and might serve as a guide during local anaesthetic interventions for dentistry, ophthalmology, plastic surgery, rhinology, neurosurgery and dermatology.
引用
收藏
页码:331 / 343
页数:13
相关论文
共 50 条
  • [1] Retrospective Morphometric Analysis of the Infraorbital Foramen with Cone Beam Computed Tomography
    Dagistan, S.
    Miloglu, O.
    Altun, O.
    Umar, E. K.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (09) : 1053 - 1064
  • [2] Morphometric Analysis of the Mandibular Canal, Anterior Loop, and Mental Foramen: A Cone-Beam Computed Tomography Evaluation
    Ahmed, Altayeb Abdalla
    Ahmed, Rawia Mohamed
    Jamleh, Ahmed
    Spagnuolo, Gianrico
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)
  • [3] Accessory infraorbital foramen location using cone-beam computed tomography
    An, Daesung
    Kumar, K. C.
    Vorakulpipat, Chakorn
    Ngamsom, Supak
    Kumchai, Thongnard
    Ruangsitt, Sunya
    Chaiyasamut, Teeranut
    Wongsirichat, Natthamet
    JOURNAL OF DENTAL ANESTHESIA AND PAIN MEDICINE, 2023, 23 (05) : 257 - 264
  • [4] Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population
    Celebi, Adalet
    Gulsun, Belgin
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 (01) : 13 - 19
  • [5] Anatomical Evaluation of the Foramen Magnum on Cone-Beam Computed Tomography Images and Review of Literature
    Bahsi, Ilhan
    Adanir, Saliha Seda
    Orhan, Mustafa
    Kervancioglu, Piraye
    Buyukbese, Zeynep Simgul
    Beger, Orhan
    Yalcin, Eda Didem
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11) : 1 - 13
  • [6] The morphometric analysis of mastoid foramen and mastoid emissary canal on cone-beam computed tomography (CBCT)
    Zeliha Zuhal Yurdabakan
    Özlem Okumuş
    Kaan Orhan
    Surgical and Radiologic Anatomy, 2023, 45 : 303 - 314
  • [7] The morphometric analysis of mastoid foramen and mastoid emissary canal on cone-beam computed tomography (CBCT)
    Yurdabakan, Zeliha Zuhal
    Okumus, Ozlem
    Orhan, Kaan
    SURGICAL AND RADIOLOGIC ANATOMY, 2023, 45 (03) : 303 - 314
  • [8] Morphometric Analysis of the Mental Foramen Using Cone-Beam Computed Tomography
    Oliveira, Rudyard dos Santos
    Coutinho, Maria Rodrigues
    Panzarella, Francine Kuhl
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [9] Morphometric Analysis of the Foramen Palatinum Majus by Cone-beam Computed Tomography
    Tassoker, Melek
    Azman, Duygu
    Aydin Kabakci, Anil Didem
    BEZMIALEM SCIENCE, 2023, 11 (01):
  • [10] Morphometric and morphological evaluation of mastoid emissary canal using cone-beam computed tomography
    Temiz, Mustafa
    Ozen, Duygu Celik
    Duman, Suayip Burak
    Bayrakdar, Ibrahim Sevki
    Kazan, Orhan
    Jagtap, Rohan
    Altun, Oguzhan
    Abdelkarim, Ahmed Z.
    Syed, Ali Z.
    Orhan, Kaan
    SCIENCE PROGRESS, 2023, 106 (02)