Axial vs Pulsatile Flow In Reversing Pulmonary Hypertension in Heart Failure Patients Supported by Left Ventricular Assist Devices

被引:0
|
作者
Jacob, L. [1 ]
Delgado, R. [1 ]
Reardon, M. [2 ]
Loebe, M. [2 ]
Gregoric, I. [1 ]
Torre-Amione, G. [2 ]
Bogaev, R. [1 ]
Frazier, O. H. [1 ]
Bruckner, B. A. [2 ]
机构
[1] Texas Heart Inst, Houston, TX 77025 USA
[2] Methodist DeBakey Heart Ctr, Houston, TX USA
来源
关键词
D O I
10.1016/j.healun.2008.11.286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
279
引用
收藏
页码:S163 / S163
页数:1
相关论文
共 50 条
  • [1] Sensitization in axial flow devices versus pulsatile left ventricular assist devices
    George, I.
    Colley, P.
    Burke, E.
    Martens, T.
    Morrow, B.
    Russo, M.
    Soneru, C.
    Tabaksblat, M.
    Spadaccio, C.
    Lill, Z.
    Cheema, F.
    Itescu, S.
    Deng, M.
    Mancini, D.
    Oz, M. C.
    Naka, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (02): : S146 - S147
  • [2] CONTINUOUS AXIAL FLOW LEFT VENTRICULAR ASSIST DEVICES IMPROVE PULMONARY HEMODYNAMICS IN PATIENTS WITH SEVERE CONGESTIVE HEART FAILURE
    Rasalingam, Ravi
    Bilhorn, Kyle R.
    Johnson, Stephanie N.
    Kapadia, Carl B.
    Makan, Majesh
    Moazami, Nader
    Perez, Julio E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] Reversal of secondary pulmonary hypertension in patients supported by left ventricular assist devices
    Bruckner, B. A.
    Jacob, L. P.
    Delgado, R.
    Reardon, M. J.
    Loebe, M.
    Gregoric, I.
    Bogaev, R. C.
    Torre-Amione, G.
    Frazier, O. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S185 - S186
  • [4] Management of hypertension in patients supported with continuous flow left ventricular assist devices
    Krishnarao, Krithika
    Krim, Selim R.
    CURRENT OPINION IN CARDIOLOGY, 2023, 38 (04) : 281 - 286
  • [5] Left ventricular assist devices as bridge to heart transplantation in congestive heart failure with pulmonary hypertension
    Haddad, H
    Elabbassi, W
    Moustafa, S
    Davies, R
    Mesana, T
    Hendry, P
    Masters, R
    Mussivand, T
    ASAIO JOURNAL, 2005, 51 (04) : 456 - 460
  • [6] Left ventricular pressure unloading witii continuous and pulsatile left ventricular assist devices in advanced heart failure patients
    Slaughter, M. S. .
    Sobieski, M. A.
    Panlalos, G. M.
    Giridharan, G. A.
    Dowling, R. D.
    Prabhu, S.
    Farrar, D. J.
    Koenig, S. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (02): : S88 - S88
  • [7] Efficacy of contnuous-flow ventricular assist devices in heart failure patients with severe pulmonary hypertension
    John, R.
    Kamdar, F.
    Boyle, A.
    Colvin-Adams, M.
    Pritzker, M.
    Missov, E.
    Liao, K.
    Joyce, L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S185 - S185
  • [8] Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support
    Amir, O
    Radovancevic, B
    Delgado, RM
    Kar, B
    Radovancevic, R
    Henderson, M
    Cohn, WE
    Smart, FW
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (04): : 391 - 394
  • [9] Left ventricular assist devices as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension
    Gkouziouta, A.
    Kogerakis, N.
    Louca, L.
    Ieromonachos, K.
    Stavridis, G. T.
    Adamopoulos, S.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1318 - 1318
  • [10] Left ventricular assist devices in patients eligible for heart transplant with irreversible pulmonary hypertension
    de Frutos, Fernando
    Diez-Lopez, Carles
    Carlos Sanchez-Salado, Jose
    Miralles, Albert
    Manito, Nicolas
    Gonzalez-Costello, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2020, 73 (07): : 583 - 586