Use of a calibrated leak to calibrate vacuum gauges

被引:10
|
作者
Mohan, P
Gupta, AC
机构
关键词
D O I
10.1016/S0042-207X(97)00021-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A calibrated leak method is reported for calibrating a spinning rotor gauge (SRG) ora capacitance diaphragm gauge (CDG) of 133 Pa full scale range. The leak element and the gauge under test are connected to a vacuum chamber and the rise of pressure with time is monitored for a known volume. From the known leak rate and vessel volume, the gas pressure after a given time is calculated, and this is compared with the indicated pressure to find the correction factor. For the SRG, extrapolation over the pressure range of 10(-2)-1 Pa allowed calculation of the gauge coefficient. The calibrations obtained were also compared with those from a static expansion method, giving an agreement of +/-1.0%. The results of the study of the behaviour of a commercial SRG over the pressure range of 1-140 Pa with three gases Ar, He and N-2, using the method are discussed together with the limitations. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:515 / 519
页数:5
相关论文
共 50 条
  • [1] USING GAS STREAMS TO CALIBRATE VACUUM GAUGES
    KHAVKIN, LP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (05): : 1209 - &
  • [2] Improving the calibration of vacuum gas flow - Control leak gauges
    Kuz'min, VV
    MEASUREMENT TECHNIQUES, 2004, 47 (06) : 568 - 570
  • [3] Improving the Calibration of Vacuum Gas Flow – Control Leak Gauges
    V. V. Kuz'min
    Measurement Techniques, 2004, 47 : 568 - 570
  • [4] Calibrated variable leak for use in ion source operation
    Langley, RA
    Dastoor, PC
    O'Connor, DJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2001, 19 (02): : 673 - 674
  • [5] IMAGE ANALYZER HELPS CALIBRATE ANALOG GAUGES
    不详
    INSTRUMENTS & CONTROL SYSTEMS, 1982, 55 (02): : 59 - 59
  • [6] Hemodynamic monitoring: To calibrate or not to calibrate? Part 2 - Non-calibrated techniques
    Bernards, Jelle
    Mekeirele, Michael
    Hoffmann, Britta
    Peeters, Yannick
    De Raes, Marijke
    Malbrain, Manu L. N. G.
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2015, 47 (05) : 501 - 516
  • [7] CALIBRATED-LEAK BALLOON - ACCURATE PLACEMENT OF THE LEAK
    OREILLY, GV
    KLEEFIELD, J
    FORREST, MD
    WANG, AM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (01) : 90 - 91
  • [8] ACCURACY OF VACUUM GAUGES
    JITSCHIN, W
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (02): : 948 - 956
  • [9] CALIBRATION OF VACUUM GAUGES
    POULTER, KF
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1977, 10 (02): : 112 - 125
  • [10] THESE VACUUM GAUGES ARE A GAS
    不详
    R&D MAGAZINE, 1994, 36 (08): : 51 - &