A Study of Inspection for Electrical Safety Systems Case Study Four Locations in Thailand

被引:0
|
作者
Charoenchit, S. [1 ]
Thongchaisuratkrul, C. [1 ]
机构
[1] King Mongkuts Univ Technol North Bangkok, Bangkok, Thailand
关键词
D O I
10.1088/1757-899X/811/1/012039
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This research presents study of inspection for electrical safety in electrical system. The four locations are observed. The objective of this research are to study the problems which may be occurred in electrical system and introduce the prevent ways. The four locations consist of 2 factories of paper and 2 animal food factories. For factory of paper, the total electrical load is 18,450 kVA which consists of 10 transformers and another 13,450 kVA which consists of 10 transformers. For the animal food 800 kVA, another is 1000 kVA which each location is a transformer. The inspected systems include transformer, main distribution board, ground and electrical wire systems. The check instruments are test oil maker, thermo scan, earth clamp tester, earth ground tester, infrared tester and outlet tester. The all data from test is analysed to compare among of four locations. For experimental results, it is of found that for transformer, the oil insulation transformer is lower than standard and silica gel is deteriorated and broken box, rubber shield and rubber gasket is broken and damage. For main distribution board, the ground value is lower than standard and the temperature of junction for breaker is high and more dust. For ground system, the ground value is lower than standard and broken. For wire system, the electrical is damaged because of heat and animal.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] PREPAREDNESS AND RESILIENCE A CASE STUDY ON CHILD SAFETY FOR SURVIVAL IN THAILAND
    Jaroenrith, Kanokporn
    Greenhalgh, Dave
    INJURY PREVENTION, 2018, 24 : A137 - A137
  • [2] SAFETY MANAGEMENT SYSTEM IN UNIVERSITY: CASE STUDY KMUTT, THAILAND
    Chaisawadi, S.
    Suwanyuen, S.
    INJURY PREVENTION, 2010, 16 : A80 - A81
  • [3] Four areas that affect electrical safety in electrical, power systems
    Consulting-Specifying Engineer Editorial Advisory Board
    不详
    Consult. Specif. Eng., 2024, 2 (47-53):
  • [4] CHEMICAL LABORATORY SAFETY IN HIGHER EDUCATION: CASE STUDY IN KMUTT THAILAND
    Chaisawadi, Suchada
    Suwanyeun, Solot
    INJURY PREVENTION, 2018, 24 : A211 - A212
  • [5] Safety Analyzes of Mechatronics Systems: a Case Study
    Aupetit, B.
    Batteux, M.
    Rauzy, A.
    Roussel, J. -M.
    IFAC PAPERSONLINE, 2017, 50 (01): : 11150 - 11155
  • [6] HOW THE CLIMATE MIGRATES. CASE STUDY FOR FOUR LOCATIONS IN THE CARPATHIAN-BASIN
    Magyari-Saska, Zsolt
    GEOGRAPHIA TECHNICA, 2022, 17 (02): : 97 - 106
  • [7] Metrological Reliability and Electrical Safety: A Case Study on Electrosurgical Equipment
    Ramezani, A.
    Golpaygani, Ali Tavakoli
    Movahedi, M. M.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 935 - 939
  • [8] Applying Systems Approach the Case Study of Tertiary Education Institutions in Thailand
    Jungthawan, Siripong
    Suharitdamrong, Vithaya
    Tiyarattanachai, Ronnachai
    2019 IEEE 6TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND APPLICATIONS (ICIEA), 2019, : 682 - 688
  • [9] Promotion systems and career development in Thailand: a case study of Siam Cement
    Wailerdsak, N
    Suehiro, A
    INTERNATIONAL JOURNAL OF HUMAN RESOURCE MANAGEMENT, 2004, 15 (01): : 196 - 218
  • [10] An investigation of solar erythemal ultraviolet radiation in the tropics: a case study at four stations in Thailand
    Janjai, Serm
    Kirdsiri, Keerati
    Masiri, Itsara
    Nunez, Manuel
    INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2010, 30 (12) : 1893 - 1903