A photoacoustic spectrometer for ozone detection

被引:1
|
作者
Telles, EM [1 ]
Bezerra, E [1 ]
Scalabrin, A [1 ]
机构
[1] Unilaser Ind & Comercio Ltda, BR-13087410 Campinas, SP, Brazil
关键词
photoacoustic spectroscopy; ozone; CO2; laser; trace gas detection;
D O I
10.1117/12.437157
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A high-resolution external laser photoacoustic spectrometer has been developed. The spectrometer was used to analyze the absorption transitions of the ozone (O-16(3)) in coincidence with the CO2 laser emission (9-10 mum) and to evaluate, its limit of sensitivity. A CO2 laser and a photoacoustic resonant cell, totally built in project, formed the spectrometer. The CO2 laser operates in 80 CW transitions distributed in the regular bands with power of up to 15W, tuned by a diffraction grating. The cell has frequency resonance of longitudinal mode close to 1600 Hz. The cell is equipped with two small electret microphones and ZnSe windows in Brewster angle. The quality factor of the cell was measured about 30 through the ozone absorption in resonance with the 9P14 line of CO2 laser. The spectrometer sensitivity limit was preliminary evaluated for ozone detection around 100ppb (214 mu gO(3)/m(3)).
引用
收藏
页码:422 / 426
页数:3
相关论文
共 50 条
  • [1] Highly sensitive electronically modulated photoacoustic spectrometer for ozone detection
    Gondal, M. A.
    Yamani, Z. H.
    APPLIED OPTICS, 2007, 46 (29) : 7083 - 7090
  • [2] A photoacoustic spectrometer for trace gas detection
    Telles, EM
    Bezerra, E
    Scalabrin, A
    JOURNAL DE PHYSIQUE IV, 2005, 125 : 885 - 888
  • [3] Sensitive UV photoacoustic detection of ozone
    Wee, TL
    Kung, AH
    NONLINEAR FREQUENCY GENERATION AND CONVERSION: MATERIALS DEVICES, AND APPLICATIONS III, 2004, 5337 : 150 - 157
  • [4] On the accuracy of aerosol photoacoustic spectrometer calibrations using absorption by ozone
    Davies, Nicholas W.
    Cotterell, Michael I.
    Fox, Cathryn
    Szpek, Kate
    Haywood, Jim M.
    Langridge, Justin M.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (04) : 2313 - 2324
  • [5] Photoacoustic detection of ozone with a red laser diode
    Keeratirawee, Kanchalar
    Hauser, Peter C.
    TALANTA, 2021, 223
  • [6] Photoacoustic detection of ozone using a quantum cascade laser
    da Silva, MG
    Vargas, H
    Miklós, A
    Hess, P
    APPLIED PHYSICS B-LASERS AND OPTICS, 2004, 78 (06): : 677 - 680
  • [7] Development of a Nonresonant Photoacoustic Gas Sensor for Ozone Detection
    Xu, Maosen
    Liu, Li
    Tian, Wei
    Xu, Yan
    Tao, Jifang
    IEEE SENSORS JOURNAL, 2024, 24 (21) : 35508 - 35515
  • [8] Photoacoustic detection of ozone using a quantum cascade laser
    M.G. da Silva
    H. Vargas
    A. Miklós
    P. Hess
    Applied Physics B, 2004, 78 : 677 - 680
  • [9] An all-optical photoacoustic spectrometer for trace gas detection
    Wang, Qiaoyun
    Wang, Jianwei
    Li, Liang
    Yu, Qingxu
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 214 - 218
  • [10] AN INFRARED PHOTOACOUSTIC SPECTROMETER
    LOW, MJD
    PARODI, GA
    INFRARED PHYSICS, 1980, 20 (05): : 333 - 340