On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14

被引:41
|
作者
Liens, Alethea [1 ,2 ]
Etiemble, Aurelien [1 ]
Rivory, Pascaline [1 ]
Balvay, Sandra [1 ]
Pelletier, Jean-Marc [1 ]
Cardinal, Sandrine [1 ]
Fabregue, Damien [1 ]
Kato, Hidemi [3 ]
Steyer, Philippe [1 ]
Munhoz, Tais [1 ]
Adrien, Jerome [1 ]
Courtois, Nicolas [2 ]
Hartmann, Daniel J. [1 ]
Chevalier, Jerome [1 ]
机构
[1] Univ Lyon, UMR CNRS 5510, MATEIS Lab, INSA Lyon, 20 Ave Albert Einstein, F-69621 Villeurbanne, France
[2] Anthogyr SAS, 2237 Ave A Lasquin, F-74700 Sallanches, France
[3] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 980011, Japan
关键词
Ti-based bulk metallic glass; biomaterials; dental application; mechanical properties; biocompatibility; MECHANICAL-PROPERTIES; IN-VITRO; FORMING ABILITY; CORROSION BEHAVIOR; AMORPHOUS-ALLOYS; NI; BIOCOMPATIBILITY; FABRICATION; VIVO;
D O I
10.3390/ma11020249
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies' prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 degrees C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.m. Moreover, the alloy shows a relatively lower Young's modulus (96 GPa) than the Ti-6Al-4V alloy (110-115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of -0.07 V/SCE and corrosion current density of 6.0 nA/cm(2)), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Ti40Zr10Cu36Pd14 bulk metallic glass as oral implant material
    Rezvan, Amir
    Sharifikolouei, Elham
    Soprunyuk, Viktor
    Schranz, Wilfried
    Todt, Juraj
    Lassnig, Alice
    Gammer, Christoph
    Sifferlinger, Nikolaus August
    Asci, Atacan
    Okulov, Ilya
    Schlogl, Sandra
    Keckes, Jozef
    Najmi, Ziba
    Cochis, Andrea
    Scalia, Alessandro Calogero
    Rimondini, Lia
    Sarac, Baran
    Eckert, Juergen
    MATERIALS & DESIGN, 2023, 233
  • [2] The Influence of Partial Replacement of Cu with Ga on the Corrosion Behavior of Ti40Zr10Cu36Pd14 Metallic Glasses
    Wei, Qi
    Gostin, Petre Flaviu
    Addison, Owen
    Reed, Daniel
    Calin, Mariana
    Bera, Supriya
    Ramasamy, Parthiban
    Davenport, Alison
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (14) : C485 - C491
  • [3] Antibacterial activity, cytocompatibility, and thermomechanical stability of Ti40Zr10Cu36Pd14 bulk metallic glass
    Rezvan, Amir
    Sharifikolouei, Elham
    Lassnig, Alice
    Soprunyuk, Viktor
    Gammer, Christoph
    Spieckermann, Florian
    Schranz, Wilfried
    Najmi, Ziba
    Cochis, Andrea
    Scalia, Alessandro Calogero
    Rimondini, Lia
    Manfredi, Marcello
    Eckert, Jurgen
    Sarac, Baran
    MATERIALS TODAY BIO, 2022, 16
  • [4] Relaxation of Ni-free Ti40Zr10Cu36Pd14 bulk metallic glass under mechanical stress
    Qiao, J. C.
    Wang, Q.
    Pelletier, J. M.
    Yao, Y.
    INTERMETALLICS, 2018, 102 : 6 - 10
  • [5] Properties of the Ti40Zr10Cu36Pd14 BMG Modified by Sn and Nb Additions
    Sypien, Anna
    Stoica, Mihail
    Czeppe, Tomasz
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2016, 25 (03) : 800 - 808
  • [6] Properties of the Ti40Zr10Cu36Pd14 BMG Modified by Sn and Nb Additions
    Anna Sypien
    Mihail Stoica
    Tomasz Czeppe
    Journal of Materials Engineering and Performance, 2016, 25 : 800 - 808
  • [7] The Effects of Cooling Rate on the Microstructure and Mechanical Properties of Ti40Zr10Cu36Pd14 Metallic Glass Matrix Composites
    Park, Seon Yong
    Lim, Ka Ram
    Na, Young Sang
    Kim, Seong Eon
    Choi, Youn Suk
    Korean Journal of Metals and Materials, 2016, 54 (11): : 802 - 807
  • [8] Insights into the crystallisation pathways in as-cast Ti40Zr10Cu36Pd14 glassy alloys
    Douest, Yohan
    Cazottes, Sophie
    Costa, Miguel B.
    Ter-Ovanessian, Benoit
    Courtois, Nicolas
    Chevalier, Jerome
    Greer, A. Lindsay
    Fabregue, Damien
    MATERIALS CHARACTERIZATION, 2024, 214
  • [9] Modification of structural, mechanical, corrosion and biocompatibility properties of Ti40Zr10Cu36Pd14 metallic glass by minor Ga and Sn additions
    Lachova, Andrea
    Stoica, Mihai
    Michalik, Stefan
    Gostin, Petre F.
    Fujioka-Kobayashi, Masako
    Schaller, Benoit
    Loeffler, Joerg F.
    Sovak, Pavol
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 940
  • [10] In vitro corrosion and biocompatibility screening of sputtered Ti40Cu36Pd14Zr10 thin film metallic glasses on steels
    Subramanian, B.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 47 : 48 - 56