Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

被引:0
|
作者
Adinehvand, K. [2 ,3 ]
Zahmatkesh, M. H. [1 ]
Aghamiri, M. R. [3 ]
Akhlaghpour, Sh. [4 ]
Bagheri, S. [1 ]
机构
[1] Novin Radiat Med Inst, Tehran, Iran
[2] Borujerd Islamic Azad Univ, Borujerd, Iran
[3] Shahid Beheshti Univ, Div Radiat Med, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Radiol, Tehran, Iran
来源
IRANIAN JOURNAL OF RADIATION RESEARCH | 2008年 / 6卷 / 01期
关键词
Polymer gels; MAGICA gel; magnetic resonance imaging (MRI); agarose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. A calibration curve (in the linear region) based on 12 dosimeters (11 irradiated and one blank) was obtained for 6 MeV electron beam. Dosimeter energy dependence was studied for electron energies of 4,6,12 and 18 MeV. Dose rate dependence was studied in 10 MeV electron beam with the use of dose rates 80,160,240,320,400 and 480 cGymin(-1). Evaluations of dosimeters were performed on Siemens Symphony, Germany, 1.5T Scanner in the head coil. A multiecho sequence with 32 equidistant echoes was used for the evaluation of irradiated polymer gel dosimeters. The parameters of the sequence were as follows: TR 3000ms, TE 20ms, Slice Thickness 4mm and FOV 256mm. Results: Polymer gel dosimeter response R2 was increased with increasing electron energy. No trend in polymer-gel dosimeter R2 dependence was found on mean dose rate for electron beams. Conclusion: In MAGICA polymer gel, the sensitivity is dependant on electron energy increase, but no dependence was observed on response to dose rate. The presence of antioxidant and oxygen scavengers in the MAGICA polymer gel is believed to cause different results. Iran. J. Radiat. Res., 2008; 6 (1): 31-36
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [1] Evaluation of dose rate and photon energy dependence of PASSAG polymer gel dosimeter
    Farhood, Bagher
    Geraily, Ghazale
    Abtahi, Seyed Mohammad Mahdi
    Ghorbani, Mahdi
    Mehdikhani, Mohamad
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 317 (02) : 1041 - 1050
  • [2] Evaluation of dose rate and photon energy dependence of PASSAG polymer gel dosimeter
    Bagher Farhood
    Ghazale Geraily
    Seyed Mohammad Mahdi Abtahi
    Mahdi Ghorbani
    Mohamad Mehdikhani
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 317 : 1041 - 1050
  • [3] Energy and dose rate dependence of BANG-2 polymer-gel dosimeter
    Novotny, J
    Spevacek, V
    Dvorak, P
    Novotny, J
    Cechak, T
    MEDICAL PHYSICS, 2001, 28 (11) : 2379 - 2386
  • [4] Assessment of photon energy and dose rate dependence of U-NIPAM polymer gel dosimeter
    Abtahi, Seyed Mohammad Mahdi
    Anaraki, Vahid
    Farhood, Bagher
    Mahdavi, Seied Rabi
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [5] Dosimetric evaluation of PASSAG-U polymer gel dosimeter: Dependence of dose rate and photon energy
    Farhood, Bagher
    Mohammadi, Kamal A. S. L.
    Sarvizadeh, Mostafa
    Aliasgharzadeh, Akbar
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (04) : 641 - 658
  • [6] Comparison of energy dependence of PAGAT polymer gel dosimeter with electron and photon beams using magnetic resonance imaging
    Azadbakht, B.
    Adinehvand, K.
    Research Journal of Applied Sciences, Engineering and Technology, 2012, 4 (03) : 236 - 240
  • [7] A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter
    Eguchi, K.
    Watanabe, Y.
    Mizukami, S.
    Maeyama, T.
    Hayashi, S.
    Gomi, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E238 - E238
  • [8] An investigation into the dose rate and photon energy dependence of the GENA gel dosimeter in the MeV range
    Abtahi, Seyed Mohammad Mahdi
    Bahrami, Farbod
    Sardari, Dariush
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 106
  • [9] The investigation of dose rate and photon beam energy dependence of optimized PASSAG polymer gel dosimeter using magnetic resonance imaging
    Liu, Bo
    Zaki, Shaima Haithem
    Garcia, Eduardo
    Bonilla, Amanda
    Thabit, Daha
    Adab, Aya Hussein
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 751 - 764
  • [10] Investigation of the beam quality and dose rate dependence of PAKAG polymer gel dosimeter in optical readout technique
    Abtahi, Seyed Mohammad Mahdi
    Habibi, Fatemeh
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):