Low-order controller design using remotely measured time delayed signals for stabilisation of equivalent power grid

被引:6
|
作者
Kishor, Nand [1 ,4 ]
Seppanen, Janne M. [1 ]
Turunen, Jukka [2 ]
Nikkila, Antti-Juhani [3 ]
Haarla, Liisa C. [1 ]
Purwar, Shubhi [4 ]
机构
[1] Aalto Univ, Dept Elect Engn, Espoo, Finland
[2] Statnett SF, Oslo, Norway
[3] Fingrid Oyj, Power Syst Operat Planning, Helsinki, Finland
[4] Motilal Nehru Natl Inst Technol, Dept Elect Engn, Allahabad, Uttar Pradesh, India
关键词
controllers; power system stability; power grids; delays; phasor measurement; electric generators; H optimisation; minimisation; rotors; load flow; low-order controller design; time delayed remote signal; equivalent power grid stabilisation; phasor measuring unit; PMU; power oscillation; synchronisation measure; Hankel singular value; remote feedback signal; H norm minimisation; measurement redundancy; rotor angle; power flow; speed deviation; generator; multistep disturbance; exciter system; complex stability radius; spectral abscissa; frequency; 0; 3 Hz to 0; 42; Hz; EMPIRICAL MODE DECOMPOSITION; SYSTEM; IDENTIFICATION; OSCILLATIONS;
D O I
10.1049/iet-gtd.2015.0268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study discusses the use of time-delayed remote signals available through phasor measuring units (PMUs) for low-order controller design in order to stabilise the power oscillations in the range of 0.3-0.42 Hz between two areas. In the proposed approach, first synchronisation measures are determined among the group of generators located in two areas. Then, an index that characterises the joint observability and controllability property in terms of Hankel singular values is defined as a criterion to preselect the remote feedback signal. Following this, a low-order controller design based on minimisation of H norm is considered. The measurement redundancy is taken into account in controller design using rotor angle, power flow or speed deviation as feedback signal from one of the generators. Additionally, if some specific PMU fails to provide measurements from a chosen generator, then controller effectiveness is guaranteed using signal from other generator in the same area. The performance of controller is verified considering single-step and multi-step disturbances applied to the reference voltage of exciter system. The comparison with design functions such as H-2 norm, complex stability radius and spectral abscissa are also presented. The analytical results confirm using H design algorithm provides better dynamic performance.
引用
收藏
页码:2575 / 2585
页数:11
相关论文
共 23 条
  • [1] Low-order controller design using global optimization
    Schmidt, DE
    Sourlas, DD
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (21) : 4555 - 4569
  • [2] Low-order H∞ controller design using LMI and genetic algorithm
    Du, HP
    Shi, XZ
    PROCEEDINGS OF THE 2002 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2002, 1-6 : 511 - 512
  • [3] Low-order H∞ controller design for discrete-time linear systems
    Zhai, G
    Tamaoki, K
    Murao, S
    PROCEEDINGS OF THE 2002 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2002, 1-6 : 2202 - 2203
  • [4] Fixed, low-order controller design with time response specifications using non-convex optimization
    Jin, Lihua
    Kim, Young Chol
    ISA TRANSACTIONS, 2008, 47 (04) : 429 - 438
  • [5] Fixed, low-order controller design with time response specifications using non-convex optimization
    Jin, Li Hua
    Kim, Young Chol
    2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 1444 - 1449
  • [6] Low-order controller design for SISO systems using coprime factors and LMI
    Wang, SP
    Chow, JH
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2000, 45 (06) : 1166 - 1169
  • [7] Low-Order Robust Damping Controller Design for Large-scale PV Power Plants
    Shah, Rakibuzzaman
    Mithulananthan, N.
    Lee, Kwang. Y.
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [8] Low-order dynamic equivalent estimation of power systems using data of phasor measurement units
    Shiroei, M.
    Mohammadi-Ivatloo, B.
    Parniani, M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 74 : 134 - 141
  • [9] Low-order H∞ robust controller design of generator system by using alternating projection algorithm
    Bu, QZ
    Mao, JQ
    2001 INTERNATIONAL CONFERENCES ON INFO-TECH AND INFO-NET PROCEEDINGS, CONFERENCE A-G: INFO-TECH & INFO-NET: A KEY TO BETTER LIFE, 2001, : D196 - D202
  • [10] Design of Optimal PI Controller with Dead-zone Link for Low-order Processes with Time Delay
    Li, X. H.
    Yu, H. B.
    Zeng, P.
    Sun, L. X.
    Yuan, M. Z.
    Zang, C. Z.
    Bian, J.
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 734 - 740