Arthroscopic versus Mini-Open Rotator Cuff Repair: Should We Ignore the Mini-Open Surgery?

被引:0
|
作者
Ozcan, M. S. [1 ]
Varol, A. [2 ]
Kilinc, B. E. [3 ]
机构
[1] Tatvan State Hosp, Dept Orthopaed & Traumatol, Minist Hlth, Bitlis, Turkey
[2] Silopi State Hosp, Dept Orthopaed & Traumatol, Minist Hlth, Sirnak, Turkey
[3] Hlth Sci Univ Istanbul Fatih Sultan Mehmet Traini, Dept Orthopaed & Traumatol, Istanbul, Turkey
关键词
rotator cuff; mini-open surgery; total arthroscopic repair; cuff tear; Constant score; ASES score; TEARS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY To compare the functional and radiological results of the total arthroscopic treatment (TAT) performed due to the rotator cuff (RC) tear problem with the results of the arthroscopically assisted mini-open surgery (AAMOS). MATERIAL AND METHODS This study conducted over a two-year period included all had TAT or AAMOS. Patients were included in the study if they had undergone arthroscopic or mini-open rotator cuff repair, with a minimum of 2 years' follow-up. Patients were divided into two groups in terms of the surgical technique performed. Patients who had TAT was included into the group 1 and, AAMOS group 2. Exclusion criteria included other significant intra-articular pathology such as SLAP lesions or glenohumeral arthrosis, previous rotator cuff surgery, massive rotator cuff tears (>5 cm), and neurologic disorders such as brachial plexopathy or suprascapular neuropathy. Every patient underwent magnetic resonance imaging evaluation before surgery and at last follow-up after surgery. Acromion typed of patients were recorded. Patients were questioned for ASES and Constant score. RESULTS Fifty-eight shoulders were included in the study. Twenty-eight patients were female and 30 were male. The mean age was 55.63 +/- 8.06 years. Both groups had 29 patients per each. Mean follow-up period was 26.26 +/- 11.46 months. There was no statistically significant difference between the mean age and gender distribution of the groups (p > 0.05). No statistically significant difference in the follow-up period between two groups (p > 0.05). No statistically significant difference was found between the postoperative ASES measurements between the two groups (p > 0.05). There was no statistically significant difference in postoperative Constant measurements between the two groups (p > 0.05). There was no statistically significant difference between the Acromion types between the two groups (p > 0.05). No statistically significant difference was found between the both groups in terms of accompanying shoulder pathology and AC joint degeneration (p > 0.05). In the postoperative MRIs of the patients, 7 patients in the Group 2 and 6 patients in the Group 1 were found to have recurrent tears. No statistically significant difference was found (p > 0.05). DISCUSSION When compared their patients who underwent RC repair by AAMOS intervention with those treated with TAT intervention and stated that the results were satisfactory for both groups and close to each other during their 2-year follow-up regardless of the tear diameter. Rotator cuff repairing with TAT is becoming a popular method of shoulder surgery. Initial reports of outcomes with this technique have indicated similar results when compared with open techniques, with less perioperative morbidity. Patients with RC tears treated by TAR, the shoulder range of motion was achieved in a shorter time and the rate of development of fibrous ankylosis was found to be lower. We performed the same configuration for the repair technique that may avoid to differ the results. Additionlay, all patients in study had the same rehabilitation protocol not to differ the results. Our study demonstrated similar results, with no differences noted in clinical outcomes between the TAT and the AAMOS for all scoring scales evaluated. Our experience with TAT notes a steep learning curve for proper technique. Certainly, surgeons may attempt a TAT, knowing that the patient's long-term outcome will not differ if the AAMOS is needed. CONCLUSIONS It must be kept in mind that both surgical methods may provide satisfactory results; the decision regarding which method should be used must be based on the skills, experience and technical oppurtunities of the orthopedic surgeon. However, any of the surgical technique is chosen, smilar excellent clinical results can be achieved.
引用
收藏
页码:369 / 374
页数:6
相关论文
共 50 条
  • [1] Repair of the rotator cuff - Mini-open and arthroscopic repairs
    Norberg, FB
    Field, LD
    Savoie, FH
    CLINICS IN SPORTS MEDICINE, 2000, 19 (01) : 77 - +
  • [2] Mini-open rotator cuff repair
    Augustine, SJ
    McCluskey, GM
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2000, 8 (03): : 229 - 238
  • [3] Arthroscopic ally assisted mini-open rotator cuff repair
    Shinners, TJ
    Noordsij, PG
    Orwin, JF
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01): : 21 - 26
  • [4] Systematic review of arthroscopic rotator cuff repair and mini-open rotator cuff repair
    Nho, Shane J.
    Shindle, Michael K.
    Sherman, Seth L.
    Freedman, Kevin B.
    Lyman, Stephan
    MacGillivray, John D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A : 127 - 136
  • [5] Arthroscopic versus mini-open rotator cuff repair:: A cohort comparison study
    Warner, JJP
    Tétreault, P
    Lehtinen, J
    Zurakowski, D
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (03): : 328 - 332
  • [6] Arthroscopic versus mini-open rotator cuff repair: A meta-analysis
    Migliorini, Filippo
    Maffulli, Nicola
    Eschweiler, Joerg
    Schenker, Hanno
    Tingart, Markus
    Betsch, Marcel
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2023, 21 (01): : E1 - E12
  • [7] Arthroscopic versus mini-open rotator cuff repair: A comparison of clinical outcome
    Sauerbrey, AM
    Getz, CL
    Piancastelli, M
    Iannotti, JP
    Ramsey, ML
    Williams, GR
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (12): : 1415 - 1420
  • [8] Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair
    Barnes, L. A. Fink
    Kim, H. M.
    Caldwell, J-M.
    Buza, J.
    Ahmad, C. S.
    Bigliani, L. U.
    Levine, W. N.
    BONE & JOINT JOURNAL, 2017, 99B (02): : 245 - 249
  • [9] Anterolateral approach for mini-open rotator cuff repair
    Chul-Hyun Cho
    Kwang-Soon Song
    Byung-Woo Min
    Gu-Hee Jung
    Young-Kuk Lee
    Hong-Kwan Sin
    International Orthopaedics, 2012, 36 : 95 - 100
  • [10] Open, Mini-open, and All-Arthroscopic Rotator Cuff Repair Surgery: Indications and Implications for Rehabilitation
    Ghodadra, Neil S.
    Provencher, Matthew T.
    Verma, Nikhil N.
    Wilk, Kevin E.
    Romeo, Anthony A.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2009, 39 (02): : 81 - 89