Phase transfer hollow fiber liquid phase microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental and biological samples

被引:26
|
作者
Guo, Xueqin [1 ]
He, Man [1 ]
Chen, Beibei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
关键词
Phase transfer hollow fiber liquid phase microextraction; Trace heavy metals; ETV-ICP-MS; Environmental water; Human urine; SINGLE-DROP MICROEXTRACTION; GAS-CHROMATOGRAPHIC DETERMINATION; INJECTION-PORT DERIVATIZATION; ETV-ICP-MS; SOLVENT-EXTRACTION; AMINO-ACIDS; WATER; CO; SEPARATION; SPECIATION;
D O I
10.1016/j.talanta.2012.10.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of phase transfer hollow fiber liquid phase microextraction (PT-HF-LPME) combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) has been developed for the determination of trace Co, Pd, Cd and Bi in environmental and biological samples. In PT-HF-LPME, an intermediate solvent (1-butanol) was added into the sample solution to ensure the maximum contact area between the target metal ions and the chelating reagent (8-hydroxyquinoline, 8-HQ), which accelerated the formation of 8-HQ-metal complexes and their subsequent extraction by extraction solvent (toluene). The experimental parameters affecting the extraction efficiency of PT-HF-LPME for the target metals were studied by simplex optimization and orthogonal array design (OAD) experiments. Under the optimized conditions, the enrichment factors for Co, Pd, Cd and Bi were 110, 393, 121 and 111-fold, respectively, the limits of detection (LODs, 3 sigma) ranged from 3.7 to 8.3 ng L-1. The relative standard deviations (RSDs, c=0.5 ng mL(-1), n=7) were 8.7. 6.2, 12.4 and 12.9% for Co, Pd, Cd and Bi, respectively. To validate the accuracy of the proposed method, two Certified Reference Materials of GSBZ50009-88 Environment Water and GBW09103 Human Urine were analyzed, and the results obtained for Cd were in good agreement with the certified values. Finally, the developed method was successfully applied to the analysis of Co, Pd, Cd and Bi in lake water and human urine samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:516 / 523
页数:8
相关论文
共 50 条
  • [1] Chip-based liquid phase microextraction combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for trace metal determination in cell samples
    Wang, Han
    Wu, Zhekuan
    Zhang, Yuan
    Chen, Beibei
    He, Man
    Hu, Bin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (10) : 1660 - 1665
  • [2] Graphene oxide-silica composite coating hollow fiber solid phase microextraction online coupled with inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental water samples
    Su, Shaowei
    Chen, Beibei
    He, Man
    Hu, Bin
    TALANTA, 2014, 123 : 1 - 9
  • [3] Dispersive liquid liquid microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic selenium in environmental water samples
    Zhang, Yuan
    Duan, Jiankun
    He, Man
    Chen, Beibei
    Hu, Bin
    TALANTA, 2013, 115 : 730 - 736
  • [4] TiO2-coated Hollow Fiber Microextraction Combined with Electrothermal Vaporization-Inductively Coupled Plasma-Mass Spectrometry for Trace Elements Analysis in Environmental Water Samples
    Wang Fan
    He Man
    Chen Bei-Bei
    Xiang Yang
    Hu Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1313 - 1320
  • [5] Evaluation of electrothermal vaporization as a sample introduction technique for the determination of trace elements in biological samples by inductively coupled plasma mass spectrometry, following dispersive liquid-liquid microextraction
    Ramos, Juliano Carvalho
    Borges, Daniel L. G.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (02) : 304 - 314
  • [6] Ionic liquids based single drop microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for determination of Co, Hg and Pb in biological and environmental samples
    Xia, Linbo
    Li, Xuan
    Wu, Yunli
    Hu, Bin
    Chen, Rui
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (11) : 1290 - 1296
  • [7] Determination of noble metals in biological samples by electrothermal vaporization inductively coupled plasma mass spectrometry, following cloud point extraction
    da Silva, MAM
    Frescura, VLA
    Curtius, AJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1941 - 1949
  • [8] A novel capillary microextraction on ordered mesoporous titania coating combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of V, Cr and Cu in environmental and biological samples
    Wu, Yiwei
    Hu, Bin
    Hu, Wenling
    Jiang, Zucheng
    Li, Boyangzi
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (04): : 467 - 475
  • [9] Simultaneous speciation of inorganic arsenic, selenium and tellurium in environmental water samples by dispersive liquid liquid microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry
    Liu, Ying
    He, Man
    Chen, Beibei
    Hu, Bin
    TALANTA, 2015, 142 : 213 - 220
  • [10] Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells
    Chen, Beibei
    Heng, Shujing
    Peng, Hanyong
    Hu, Bin
    Yu, Xu
    Zhang, Zhiling
    Pang, Daiwen
    Yue, Xin
    Zhu, Ying
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (12) : 1931 - 1938